===================== Product Identification =====================
MSDS NAME:ALUMINUM POWDER, MILA-512
NIIN:00-628-3382
Status Code:A
MSDS Number: CJNQV
=== Responsible Party ===
Company:AMPAL INC
Address:ROUTE 202
Box:2270
City:FLEMINGTON
State:NJ
ZIP:08822
Country:US
Info Phone Num:908-782-5454
Emergency Phone Num:800-424-9300
Chemtrec Ind/Phone:(800)424-9300
CAGE:0BPJ5
=== Contractor Identification ===
Company:AMPAL INC
Address:ROUTE 202
Box:2270
City:FLEMINGTON
State:NJ
ZIP:08822
Country:US
Phone:908-782-5454
CAGE:0BPJ5
============= Composition/Information on Ingredients =============
Name:ALUMINIUM
CAS:7429-90-5
RTECS #:BD0330000
> Wt:99.
Other REC Limits:OSHA PEL:5 MG/M3 (M)
OSHA PEL:15 MG/M3
ACGIH TLV:10 MG/M3
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ALUMINUM, METALLIC, POWDER IS AN EYE
AND MUCOUS MEMBRANE IRRITANT. TARGET ORGANS: EYES, SKIN, LUNGS,
MUCOUS MEMBRANES.
Explanation of Carcinogenicity:NOT LISTED.
Medical Cond Aggravated by Exposure:
======================= First Aid Measures =======================
Eyes: IMMEDIATELY WASH WITH LARGE AMOUNTS OF WATER FOR AT
LEAST 15 MINUTES, OCCASIONALLY LIFTING LOWER AND UPPER LIDS. GET
MEDICAL ATTENTION IMMEDIATELY. SKIN: FLUSH CONTAMINATED SKIN WITH
WATER. GET MEDICAL ATTENTION IF IRRITATION OCCURS.INHALATION: IF A
PERSON BREATHES IN LARGE AMOUNTS OF THIS CHEMICAL, MOVE EXPOSED
PERSON TO FRESH AIR AT ONCE. IF BREATHING HAS STOPPED PERFORM
ARTIFICIAL RESPIRA TION. KEEP AFFECTED PERSON WARM AND AT REST. GET
MEDICAL ATTENTION AS SOON AS POSSIBLE. INGESTION: CALL MD
IMMEDIATELY .
===================== Fire Fighting Measures =====================
Autoignition Temp:>590.C, 1094.F
Autoignition Temp Text:SUPDAT
Lower Limits:0.040 OZ/FT3
Extinguishing Media:DRY SAND, DRY INERT GRANULAR MATERIAL OR POWDER, OR
APPROVED DRY POWDER EXTINGUISHING AGENT.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:HMIS RATING: HEALTH - 0; FLAMMABILITY -
4; REACTIVITY - 1.
================== Accidental Release Measures ==================
Spill Release Procedures:NEVER EMPLOY WATER, HAVE SAND PAILS AVAILABLE.
SWEEP SPILL GENTLY TO AVOID DUST CLOUD FORMATION, USE NON-SPARKING,
NON-STATIC GENERATING IMPLEMENTS.
====================== Handling and Storage ======================
Handling and Storage Precautions:PROTECT AGAINST WATER. STORE IN A
COOL, DRY PLACE AWAY FROM INCOMPATIBLE CHEMICALS AND POSSIBLE
SOURCES OF IGNITION.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WEAR NIOSH APROVED DUST MASK.
Ventilation:SUFFICIENT VENTILATION, IN BOTH VOLUME AND PATTERN, SHOULD
BE PROVIDED TO KEEP AIR CONTAMINATION BELOW CURRENT APPLICABLE OSHA
PELS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:CONTACT LENSES SHOULD NOT BE WORN WHEN WORKING
WITH THIS CHEMICAL.
Supplemental Safety and Health
PHYSICAL DATA: MOLECULAR WEIGHT: 26.99. FIRE & EXPLO DATA: AUTOIGNITION
TEMP: CLOUD - 1202F(650C); LAYER - 1094F (590C). -- MATLS TO AVOID:
MAGNESIUM PLUS POTASSIUM CHLORATE, SODIUM CARBONATE, SULFATE S,
DIBORANE.
================== Physical/Chemical Properties ==================
Boiling Pt:=2630.C, 4766.F
Melt/Freeze Pt:=660.C, ######F
Vapor Pres:1 MM HG @ 68F (20C)
Spec Gravity:2.7 (H*2O=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:SILVERY-WHITE POWDER.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ACIDS, STRONG ALKALIES, STRONG BASES, STRONG OXIDIZERS, SILVER
CHLORIDE, IODATES, CHLORINATED HYDROCARBONS, OXIDES, NITRITES,
NITRATES, CARBONDISULFIDE, CHLORIDES, SODIUM PEROXIDE PLUS CARBON
DIOXIDE, SULFUR DICHLORIDE, PAL
Hazardous Decomposition Products:ALUMINUM REACTS WITH WATER, ACIDS AND
ALKALIES TO FORM COMBUSTIBLE HYDROGEN GAS.
Conditions to Avoid Polymerization:HAZARDOUS POLYMERIZATION CANNOT
OCCUR.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF I/A/W LOCAL, STATE AND FEDERAL
REGULATIONS.
===================== Regulatory Information =====================
SARA Title III Information:THIS PRODUCT CONTAINS THE FOLLOWING TOXIC
CHEMICALS SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 313 OF
THE EMERGENCY PLANNING AND COMMUNITY RIGHT-TO-KNOW ACT OF 1986 AND
OF 40 CFR 372: ALUMINUM - CAS # 7429-90-5 - >99% BY WT.
State Regulatory Information:
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|