===================== Product Identification =====================
MSDS NAME:MILITEC-1
NIIN:01-415-9114
Status Code:A
MSDS Number: CJNSY
=== Responsible Party ===
Company:MILITEC, INC
Address:12092 ELL LANE
City:WALDORF
State:MD
ZIP:20602
Country:US
Info Phone Num:301-893-3910
Emergency Phone Num:703-528-8371
CAGE:TO323
=== Contractor Identification ===
Company:MILITEC INC
Address:11828 PIKA DR
Box:City:WALDORF
State:MD
ZIP:20602
Country:US
Phone:301-893-3910
Contract Num:SP0450-99-M-B235
CAGE:0KXE0
Company:MILITEC, INC
Address:12092 ELL LANE
Box:City:WALDORF
State:MD
ZIP:20602
Country:US
Phone:301-893-3910
CAGE:TO323
============= Composition/Information on Ingredients =============
Name:NON-HAZARDOUS INGREDIENTS
= Wt:100.
Other REC Limits:NONE RECOMMENDED
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION MAY CAUSE SOME TRANSIENT
IRRITATION TO UPPER RESPIRATORY TRACT. EYE EXPOSURE CAN CAUSE SOME
TRANSIENT EYE IRRITATION. PROLONGED OR REPEATED SKIN CONTACT MAY
CAUSE TRANSIENT IRRITATION.
Explanation of Carcinogenicity:MATERIALS IN THIS PRODUCT ARE NOT KNOWN
TO BE CARCINOGENIC OR CONTAIN GREATER THAN 0.1% CARCINOGENIC
COMPOUNDS WHICH REQUIRE REPORTING UNDER 29 CFR 1910.1200. PCB'S NOT
DETECTED AT OR ABOVE 2 PPM THRE SHOLD DETECTION LIMIT.
Effects of Overexposure:EYES-IRRITATION, BURNING SENSATION.
INHALATION-UPPER RESIRATORY TRACT IRRITATION. SKIN-TRANSIENT
IRRITATION, BURNING SENSATION, DEFATTING, DERMATITIS.
Medical Cond Aggravated by Exposure:PERSONS WITH PRE-EXISTING SKIN
DISORDERS MAY BE MORE SUSCEPTIBLE TO THE EFFECTS OF THIS PRODUCT.
======================= First Aid Measures =======================
First Aid:INHALED-REMOVE TO FRESH AIR. GET MEDICAL HELP IF SYMPTOMS
PERSIST.EYES-FLUSH WITH WATER FOR 15 MINUTES. HOLD EYELIDS OPEN.
GET MEDICAL HELP IF SYMPTOMS PERSIST.SKIN-WIPE OFF EXCESS. WASH
SKIN WITH SOA P & WATER. GET MEDICAL HELP IF SYMPTOMS PERSIST.
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:=210.C, 410.F
Autoignition Temp:=379.4C, 715.F
Upper Limits:UNKNOWN.
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM/DRY CHEMICAL.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND
NIOSH-APPROVED SELF CONTAINED BREATHING APPARATUS. COOL FIRE
EXPOSED CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:NONE.
================== Accidental Release Measures ==================
Spill Release Procedures:CONTAIN LIQUIDS & CONTROL DISCHARGES TO
STREAMS OR SEWER SYSTEMS UNDER CONDITIONS ACCEPTABLE TO LOCAL,
STATE AND FEDERAL AUTHORITIES. APPLY ABSORBENT MATERIALS & SWEEP UP
& PLACE WASTE IN A SUITABLE & PROPERLY LABELED CONTAINER FOR
DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:TYPICAL FOR OTHER HYDROCARBON
LUBRICANTS. KEEP AWYA FROM OPEN FLAME. KEEP OUT OF REAH OF
CHILDREN. KEEP CONTAINER CLOSED WHEN NOT IN USE. STORE IN ORIGINAL
CONTAINER.
Other Precautions:KEEP OFF FOODSTUFFS. AVOID EYE CONTACT. AVOID
REPEATED AND/OR PROLONGED SKIN CONTACT. WASH THOROUGHLY AFTER
HANDLING. AVOID BREATHING MIST.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE NORMALLY REQUIRED. IF ENGINEERING CONTROLS
FAIL OR NON-ROUTINE USE OR AN EMERGENCY OCCURS; WEAR AN MSHA/NIOSH
APPROVED RESPIRATOR WITH ORGANIC VAPOR CARTRIDGE OR AN AIR-SUPPLIED
RESPIRATOR OR SCB A, AS REQUIRED. USE IAW 29 CFR 1910.134.
Ventilation:NONE NORMALLY REQUIRED. DLA-HMIS: USE ADEQUATE VENTILATION
TO KEEP OIL MISTS OF THIS MATERIAL BELOW PEL.
Protective Gloves:RUBBER, IF DESIRED.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:NO SPECIAL EQUIPMENT REQUIRED. HOWEVER, GOOD
PERSONAL HYGIENE PRACTICES SHOULD ALWAYS BE FOLLOWED.
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE..
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================== Physical/Chemical Properties ==================
HCC:V6
Boiling Pt:=275.6C, 528.F
Melt/Freeze Pt:=-42.8C, -45.F
M.P/F.P Text:ASTM D97 POUR POINT
Vapor Density:NONE@70F
Spec Gravity:1.142
Viscosity:43.4CST @100F
Evaporation Rate & Reference:NEGLIGIBLE LOSS @ 70F
Solubility in Water:SLIGHT (<1%)
Appearance and Odor:CLEAR AMBER LIQUID; MILD ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG REDUCING AGENTS.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:WHEN BURNING, MAY PRODUCE CARBON
MONOXIDE (TYPICAL OF ORGANIC LUBRICANTS) AND HYDROGEN CHLORIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
=================== Toxicological Information ===================
Toxicological Information:NONE SPECIFIED BY MANUFACTURER.
===================== Ecological Information =====================
Ecological:NONE SPECIFIED BY MANUFACTURER.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL MUST MEET ALL FEDERAL, STATE & LOCAL
REGULATIONS. DISPOSE IN ACCORDANCE TO REGULATIONS APPROPRIATE FOR
WASTE OIL. FOR ANY QUESTIONS, CONTACT THE APPROPRIATE REGULATORY
AGENCY.
=================== MSDS Transport Information ===================
Transport Information:NONE SPECIFIED BY MANUFACTURER.
===================== Regulatory Information =====================
SARA Title III Information:NONE SPECIFIED BY MANUFACTURER.
Federal Regulatory Information:TSCA INVENTORY STATUS: AALL COMPONENTS
REGISTERED. US OSHA HAZARD COMMUNICATION STANDARD: PRODUCT ASSESSED
IN ACCORDANCE WITH OSHA 29 CFR 1910.1200 AND DETERMINED NOT TO BE
HAZARDOUS.
State Regulatory Information:NONE SPECIFIED BY MANUFACTURER.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|