===================== Product Identification =====================
MSDS NAME:PEACOCK #1 CASTOR OIL
NIIN:00-270-0047
Status Code:A
MSDS Number: CLNQW
=== Responsible Party ===
Company:GEO.PFAU'S SONS CO,INC.
Address:800 WALL STREET
Box:7
City:JEFFERSONVILLE
State:IN
ZIP:47130-3619
Country:US
Info Phone Num:812-283-6697
Emergency Phone Num:(812) 283-6697
CAGE:2W231
=== Contractor Identification ===
Company:GEO.PFAU'S SONS CO,INC.
Address:800 WALL STREET
Box:7
City:JEFFERSONVILLE
State:IN
ZIP:47130-3619
Country:US
Phone:812-283-6697
CAGE:2W231
Company:SDB CONSULTANTS LTD
Address:401 WHITNEY AVE SUITE 120
Box:City:GRETNA
State:LA
ZIP:70056
Country:US
Phone:504-366-9105
Contract Num:SP0450-01-M-LR98
CAGE:0PGK2
============= Composition/Information on Ingredients =============
Name:CASTOR OIL
CAS:8001-79-4
RTECS #:FI4100000
= Wt:100.
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE CONTACT: AT AMBIENT TEMPERATURE:
SLIGHT EYE IRRITATION MAY OCCUR. AT ELEVATED TEMPERATURE: VAPOR MAY
CAUSE IRRITATION. OIL BURNS MAY OCCUR. SKIN CONTACT: AMBIENT
TEMPERATURE: SLIGHT SKIN IRRITATIO N MAY OCCUR. ELEVATED
TEMPERATURE: OIL-TYPE BURNS MAY OCCUR. INHALATION: AMBIENT
TEMPERATURE: NONE ANTICIPATED. ELEVATED TEMPERATURE: MAY PRODUCE
VARIOUS CARBON OXIDES WHICH CAUSE IRRITATION TO THE RE SPIRATORY
TRACT. INGESTION: NOT EXPECTED TO BE ACUTELY TOXIC; MAY HAVE A
LAXATIVE EFFECT.
Explanation of Carcinogenicity:NOT LISTED AS A CARCINOGEN BY NATIONAL
TOXICOLOGY PROGRAM, IARC MONOGRAPHS, OSHA.
Effects of Overexposure:SKIN CONTACT: IRRITATION, BURNS. EYE CONTACT:
IRRITATION, BURNS. INHALATION: IRRITATION. INGESTION: LAXATIVE
EFFECT.
Medical Cond Aggravated by Exposure:NONE KNOWN.
======================= First Aid Measures =======================
First Aid:INHALATION: MOVE AFFECTED SUBJECT TO FRESH AIR AND CONSULT A
PHYSICIAN IF IRRITATION PERSISTS. INGESTION: NOT ANTICIPATED TO BE
TOXIC--MAY HAVE A LAXATIVE EFFECT--CONSULT PHYSICIAN. SKIN: WHEN
MOLTEN OR HEATED, WILL CAUSE OIL-TYPE BURNS. TREAT AS SUCH. WASH
AFFECTED SKIN AREA WITH SOAP AND WATER. EYES: FLUSH EYES WITH WATER
AND CONSULT PHYSICIAN.
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:>229.4C, 445.F
Extinguishing Media:USE NO WATER. TREAT AS AN OIL FIRE. USE CARBON
DIOXIDE, FOAMITE, SAND, OR SODIUM BICARBONATE.
Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR SELF-CONTAINED
BREATHING APPARATUS AND PROTECTIVE GEAR TO PREVENT CONTACT WITH
SKIN AND EYES.
Unusual Fire/Explosion Hazard:COMBUSTION GENERATES TOXIC FUMES
CONTAINING CARBON OXIDES.
================== Accidental Release Measures ==================
Spill Release Procedures:SPILL AREA MAY BE SLICK OR SLIPPERY. AVOID
FALLS, OTHER ACCIDENTS. CONTAIN SPILLS WITH INERT MATERIAL (SAND,
EARTH, ETC). MATERIAL CAN BE RECOVERED FROM GROUND BY PUMP, SHOVEL,
OR ABSORPTION. CHECK L OCAL, STATE, AND FEDERAL REGULATIONS AS TO
DISPOSAL. KEEP SPILLS AND CLEANING RUNOFF OUT OF OPEN BODIES OF
WATER AND SEWERS. MATERIAL IS BIODEGRADABLE, PRODUCING HIGH B.O.D.
(CONTD. SEE "OTHER INFO")
====================== Handling and Storage ======================
Handling and Storage Precautions:MAINTAIN TEMPERATURE AT A MAXIMUM 50C
FOR STORAGE. AVOID STORAGE AND TRANSFER FACILITIES CONSTRUCTED OF
COPPER, COPPER ALLOYS AND ELEMENTS 24 THROUGH 30.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NEEDED ONLY AT ELEVATED TEMPERATURES OR UNDER
CONDITIONS OF MISTING. USE AN OSHA OR NIOSH APPROVED RESPIRATOR.
LOCAL EXHAUST NOT NEEDED AT AMBIENT TEMPERATURE. GENERAL MECHANICAL
VENTILATION IS RECOMM ENDED.
Ventilation:USE OF PRODUCT AT AMBIENT, NONE REQUIRED OTHER THAN GENERAL
PURPOSE VENTILATION. LOCAL EXHAUST RECOMMEND AT ELEVATED
TEMPERATURE OR IN PRESENCE OF MIST OR FUMES
Protective Gloves:ABOVE AMBIENT, NORMAL OIL-RESISTANT THERMAL
PROTECTION IS RECOMMENDED.
Eye Protection:SAFETY GLASSES OR FACE SHIELD MAY BE DESIRED WITH USE OF
PRODUCT AT AMBIENT.
Other Protective Equipment:NONE AT AMBIENT--NORMAL OIL-RESISTANT
THERMAL PROTECTION WHEN HEATED.
Supplemental Safety and Health
GLOVES ARE GENERALLY NOT REQUIRED AT AMBIENT TEMPERATURE UNLESS
INDIVIDUAL DISPLAYS SIGNS OF IRRITATION FROM EXPOSURE. GENERAL USE
HAS NOT INDICATED EYE IRRITATION WITH USE OF PRODUCT AT AMBIENT.
================== Physical/Chemical Properties ==================
HCC:V5
Boiling Pt:=232.2C, 450.F
B.P. Text:MIN.
Melt/Freeze Pt:M.P/F.P Text:NIL
Vapor Pres:@300C: 0.05 MM
Vapor Density:>1(AIR=1)
Spec Gravity:0.945 - 0.965 (WATER=1)
Viscosity:1300 - 1400 SUS @ 100F.
Evaporation Rate & Reference:<1, NOT VOLATILE AMBIENT
Solubility in Water:SLIGHT
Appearance and Odor:COLORLESS TO PALE YELLOW VISCOUS LIQUID;
CHARACTERISTIC ODOR.
Percent Volatiles by Volume:NEGLIGIBLE
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING MATERIALS AND CONTACT WITH ELEMENTS 24 THROUGH 30.
Stability Condition to Avoid:MATERIAL IS CONSIDERED STABLE AT AMBIENT.
HOWEVER, AS TEMPERATURE ELEVATES, NORMAL FAT OXIDATION WILL
ACCELERATE. CONTACT WITH METALS CAUSES SLOW CORROSION AND
DISCOLORATION.
Hazardous Decomposition Products:OVERHEATING MAY PRODUCE CARBON OXIDES
(TO INCLUDE ACROLEIN). AS WITH ANY ORGANIC MATERIAL COMBUSTION WILL
PRODUCE CARBON DIOXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
=================== Toxicological Information ===================
Toxicological Information:ACUTE:AS RECEIVED, MATERIAL IS NOT KNOWN TO
BE ACUTELY TOXIC. HOWEVER, WHEN OVERHEATED, PEACOCK CASTOR OIL WILL
PRODUCE ACROLEIN AND OTHER CARBON OXIDES WHICH MAY CAUSE TEMPORARY
BURNING OF THE EYES A ND RESPIRATORY DISCOMFORT. CHRONIC: AS
RECEIVED, MATERIAL IS NOT KNOWN TO HAVE CHRONIC TOXIC EFFECTS.
MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE: NONE KNOWN.
CHEMICAL LISTED AS A CARCINOGEN: NTP, IARC MONOGRAPHS, AND OSHA
DOES NOT LIST PRODUCT AS A CARCINOGEN. OSHAPERMISSIBLE LIMIT, ACGIH
THRESHOLD LIMIT VALUE, ANDOTHER EXPOSURE LIMITS: NONE KNOWN.
===================== Ecological Information =====================
Ecological:WASTE DISPOSAL: MATERIAL IS COMPLETELY BIODEGRADABLE, AS
RECEIVED, IT MAY BE INCINERATED OR BURIED AS NON-HAZARDOUS WASTE.
ANY USE OF PRODUCT MAY ALTER OR CONTAMINTE, THUS CHANGING WASTE
HAZARD CLASS. CHECK LOCAL, STATE, AND FEDERAL REGULATIONS AS TO
DISPOSAL.
==================== Disposal Considerations ====================
Waste Disposal Methods:MATERIAL IS COMPLETELY BIODEGRADABLE. AS
RECEIVED, IT MAY BE INCINERATED OR BURIED AS NON-HAZARDOUS WASTE.
ANY USE OF PRODUCT MAY ALTER OR CONTAMINATE, THUS CHANGING WASTE
HAZARD CLASS. CHECK LOCAL, S TATE, AND FEDERAL REGULATIONS AS TO
DISPOSAL.
=================== MSDS Transport Information ===================
Transport Information:U.S. D.O.T. HAZARD CLASS: NOT REGULATED.
===================== Regulatory Information =====================
SARA Title III Information:SECTION 311 / 312, (40 CFR 3700)
INFORMATION: THIS PRODUCT IS NOT A HAZARDOUS CHEMICAL UNDER 29 CFR
1910.1200 AND, THEREFORE, IS NOT COVERED BY TITLE I I I OF SARA.
SECTION 313, (40 CFR 372) INFORMAT ION: THIS PRODUCT DOES NOT
CONTAIN A CHEMICAL WHICH IS LISTED IN SECTION 313 ABOVE DE MINIMIS
CONCENTRATIONS. CERCLA INFORMATION (40 CFR 302.4): RELEASES OF THIS
MATERIAL TO AIR OR LAND ARE NOT REPORT ABLE TO NATIONAL RESPONSE
CENTER UNDER CERCLA OR TO THE STATE AND LOCAL EMERGENCY PLANNING
COMMITTEES UNDER SARA TITLE I I I SECTION 304. RELEASES TO WATER
MAY BE REPORTABLE AS AN OIL SPILL AND SHOULD BE REPORTED TO
APPROPRIATE AGENCIES.
Federal Regulatory Information:RCRA INFORMATION: AS RECEIVED, THIS
PRODUCT IS CLASSIFIED AS A NON-HAZARDOUS WASTE UNDER CRITERIA OF
THE RESOURCE CONSERFATION ANFD RECOVERY ACT (40 CFR 216). CHEMICAL
CONTROL LAW STATUS: ALL COMPONEN TS OF THIS PRODUCT ARE LISTED OR
ARE EXCLUDED FROM LISTING ON THE U.S. TOXIC SUBSTANCES CONTROL ACT
(TSCA) CHEMICAL SUBSTANCE INVENTORY.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|