===================== Product Identification =====================
MSDS NAME:ADHESIVE 3501A SCOTCH-WELD BRAND STRUCTURAL
NIIN:01-107-3981
Kit Part:Y
MSDS Number: BGMFC
=== Responsible Party ===
Company:SEMCO
CAGE:KO860
=== Contractor Identification ===
Company:PRC-DESOTO INTL INC
Address:5454 SAN FERNANDO RD
Box:1800
City:GLENDALE
State:CA
ZIP:91203
Country:US
Phone:818-240-2060/800-228-5635
CAGE:92108
Company:SEMCO
CAGE:KO860
============= Composition/Information on Ingredients =============
Name:ETHYLENE GLYCOL (SARA III)
CAS:107-21-1
RTECS #:KW2975000
Fraction by Wt: <1%
OSHA PEL:C 50 PPM
ACGIH TLV:C 50 PPM,VAPOR; 9192
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Name:POLYNERCAPTAN RESIN
Name:POLYAMIDE RESIN
===================== Hazards Identification =====================
Effects of Overexposure:EYES:IRRITATION,IRRITATES SKIN. VAPORS
IRRITATION NOSE AND THROAT.
======================= First Aid Measures =======================
Eyes: FLUSH FOR TEN MINUTES.CALL DOCTOR. SKIN:IMMEDIATELY
WASH WITH SOAP AND WATER. WASH CONTAMINATED CLOTHING BEFORE REUSE.
===================== Fire Fighting Measures =====================
Flash Point:<200F <93C
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:CO*2,FOAM,DRY CHEMICAL
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:NONE
================== Accidental Release Measures ==================
Spill Release Procedures:COLLECT SPILLED MATERIAL. CLEAN UP RESIDUE AND
AREA. PLACE A METAL CONTAINER
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID EYE AND SKIN CONTACT.AVOID BREAT
VAPORS OF HEATED ACCELERATOR,ADHESIVE.KEEP OUT OF CHILDREN'S REACH
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NA
Ventilation:IF MATERIAL IS HEATED
Protective Gloves:IMPERVIOUS
Eye Protection:SAFETY GLASSES
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
HCC:V4
Spec Gravity:1.4
Solubility in Water:VERY SLIGHT
Appearance and Odor:BLACK PASTE
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:SO*2,CO,CO*2,AND SMOKE PARTICLES
==================== Disposal Considerations ====================
Waste Disposal Methods:TWO-PART SYSTEM. COMBINE PARTS A&B. WHEN FINALLY
CURED MAY BE DISPOSED OF IN SANI LANDFILL IN ACCORDANCE WITH LOCAL,
STATE,AND FEDERAL REGULATIONS. DISP OF PART A IN SANITARY LANDFILL
CONFORM TO REGS
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|