===================== Product Identification =====================
MSDS NAME:COAT COMP METAL PRETREAT ID 728013 PART A
NIIN:00-850-7076
Kit Part:Y
MSDS Number: BHMWY
=== Responsible Party ===
Company:PRATT & LAMBERT, INC.
Address:16116 E 13TH ST
Box:2153
City:WICHITA
State:KS
ZIP:67201
Country:US
Preparer's Name:W.A. ELLISON
CAGE:FO127
=== Contractor Identification ===
Company:PRATT & LAMBERT, INC/BUFFALO, NY 14240
Box:22
CAGE:FO127
Company:PRATT AND LAMBERT INC
Address:Box:6027
City:CLEVELAND
State:OH
ZIP:44101-1027
Country:US
Phone:216-566-2902
CAGE:61196
============= Composition/Information on Ingredients =============
Name:ISOPROPYL ALCOHOL (SARA III)
CAS:67-63-0
RTECS #:NT8050000
Fraction by Wt: 65%
OSHA PEL:400 PPM/500 STEL
ACGIH TLV:400 PPM/500STEL;9192
Name:N-BUTYL ALCOHOL (SARA III)
CAS:71-36-3
RTECS #:EO1400000
Fraction by Wt: 15%
OSHA PEL:100 PPM
ACGIH TLV:S, C 50 PPM; 9293
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:ZINC CHROMATE
CAS:13530-65-9
RTECS #:GB3290000
Fraction by Wt: 10%
OSHA PEL:0.1 MG/M3 (CRO3)
ACGIH TLV:0.01MG/M3(CR)A1;9192
Name:TALC (CONTAINING NO ASBESTOS)
CAS:14807-96-6
RTECS #:WW2710000
Fraction by Wt: <5%
OSHA PEL:2 MG/M3 RDUST
ACGIH TLV:2 MG/M3 RDUST; 9192
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:REPEAT/PROLONGED OVEREXPSR TO
RELATIVELY INSOL CHROMATES MAY CAUSE LUNG CANCER. REPORTS HAVE
ASSOCIATED PROLONGED/ REPEATED OCCUP OVEREXPOSURE TO SOLVENTS WITH
PERMANENT BRAIN/NERVOUS SYSTEM DAMAGE. I NTENTIONAL MISUSE MAY BE
HARMFUL/FATAL.ASPIRATION INTO LUNGS CAN CAUSE CHEMICAL PNEUMONITIS
WHICH CAN BE FATAL.
Explanation of Carcinogenicity:ZINC CHROMATE HAS BEEN LISTED AS A
POTENTIAL CARCINOGEN
Effects of Overexposure:INGST:GASTROINTESTINAL IRRITATION, NAUSEA,
VOMITING. INHAL: NOSE/THROAT IRRITATION. HI CONCENT MAY CAUSE ACUTE
CENTRAL NERVOUS SYSTEMDEPRESS W/HEADACHES, DIZZINESS, NAUSEA, &
CONFUSION; EYE: IRRITATIO N SKIN: LIQ MATL ASORBED THROUGH SKIN IN
HARMFUL AMOUNTS MAY DEFATTING/IRRI SKIN
======================= First Aid Measures =======================
First Aid:INGST: DO NOT INDUCE VOMIT CALL HOSPITAL OR PHYSICIAN
IMMEDIATELY. INHAL: REMOVE TO FRESH AIR IMMEDIATELY IF BREATHING
HAS STOPPED GIVE CPR, GET MEDICAL ATTENTION IMMEDIATELY. SKIN:
REMOVE CONTAMINATE D CLOTHES WASH AFFECTED AREA WITH SOAP AND WATER
GET MEDICAL ATTENTION IMMEDIATELY.
===================== Fire Fighting Measures =====================
Flash Point:53F/12C
Extinguishing Media:NFPA CL B FIRE EXTING, CARBON DIOXIDE, ALL PUR DRY
CHEM, ALCOHOL FOAM, POLYMER FOAM IF PREFERRED FOR LARGE FIRES
Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR SCBA.WATER MAYBE
INEFFECTIVE BUT MAYBE USED TO COOL CONTAINER TO PREVENT PRESS
BUILDUP/AUTO IGN/EXPLSN. FOG NOZZLES IS PREFERRED W/WTR.
Unusual Fire/Explosion Hazard:EMEGENCY COND OVEREXP TO DECOMP PRODUCTS
MAY CAUSE HEALTH HAZARD. SYMPTOM MAY NOT BE IMMEDIATELY APPARENT.
OBTAIN MEDICAL ATTENTION. WARNING! FLAMMABLE
================== Accidental Release Measures ==================
Spill Release Procedures:ELIMINATE ALL SOURCES OF IGNITION.DIKE &
CONTAIN SPILL W/INERT MATERIAL,SAND,EARTH. TRANSFER LIQUIDTO
COVERED METAL CONTAINER FOR RECOVERY/DISPOSAL. USE ONLY NON
SPARKING TOOLS. PREVENT CONTAMINATIONO F SEWERS, STREAMS, AND
GROUNDWATER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT STORE ABOVE 95 DEG F. STORE LRG
AMTS IN COMPLIANCES W/OSHA 29CFR1910.106. NEVER USE PRESSURE TO
EMPTY. CLOSE CONTAINER AFTER EACH USE.
Other Precautions:DO NOT TAKE INTERNALLY. KEEP AWAY FROM CHILDREN.
EMPTY CONTAINER MUST NOT BE WASHED & REUSED FOR ANY PURPOSE.
CONTAIN SHOULD BE GROUNDED/BONDED TO THE RECEI-VING CONTAINER. DO
NOT WELD, BRAZE, CUT ON EMPTY CONTAINER.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:DEPENDS UPON LEVEL/DURATION OF EXP/COND OF USE.
GENERAL EXP TO ORGANIC CHEM SUCHAS THOSE CONTAIN IN THIS PRODUCT,
NOT REQUIRED USE OF RESPIR PROTEC IF WELL VENTAREA. RESTRIC: NIOSH
APPROVE CHEM CARTRI DGE/MECH PREFILTER/AIR SUPPLIED RESPIRAT
Ventilation:GENERAL DILUTION & LOCAL EXHAUST IF SUFFICIENT VOL &
PATTERNTO MAINTAIN LOWEST EXPOSURE LIMITS
Protective Gloves:SOLVENT IMPERMEABLE GLOVES
Eye Protection:SAFETY SPECTACLES W/SIDE/FACE SHIELDS
Other Protective Equipment:NOT LIKELY TO BE NEEDED
Supplemental Safety and Health
KEY1:F3.
================== Physical/Chemical Properties ==================
HCC:F5
Boiling Pt:B.P. Text:180-244 F
Vapor Density:> AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:NEGLIGIBLE
Percent Volatiles by Volume:89
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS OR ALKALINE MATERIALS
Stability Condition to Avoid:KEEP AWAY FROM HEAT, SPARKS AND FLAME
Hazardous Decomposition Products:BURNING,HEATED BY WELD/CUTTING,PRODUCE
SMOKE,CARBON MONOXIDEDIOXIDE. OXIDE CHROMIUM, OF ZINC, MET FLAM
FEVER
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH
FEDERAL/STATE/LOCAL REGULATIONS. DO NOT INCINERATE CLOSED
CONTAINERS. OBSERVE PRECAUTIONS FOR DISPOSAL OF FLAMM
MATERIALCONTAM ABSORB DISPOSE IN HAZARD WASTE LANDFILL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|