MATERIAL SAFETY DATA SHEET
GROUT SEALER CH05GL
PRODUCT NAME:
SECTION 1: PRODUCT INFORMATION
PRODUCT NAME: Grout Sealer
MANUFACTURER:
Hydro-Force Manufacturing
4282 S 590 W
Salt Lake City, UT 84123
Telephone: 801-261-1282
Prepared 5/1/08
EMERGENCIES: (800) 535-5053 (Infotrac)
Hazard Rating (Zero=Insignificant 1= Slight 2= Moderate 3= High 4= Extreme)
Fire: 0 Health: 1 Reactivity: 0
SECTION 2: COMPOSITION/INFORMATION ON INGREDIENTS
There are no components contained in this material above 1% that are considered hazardous
under 29CFR1910.1200.
SECTION 3: HAZARDS IDENTIFICATION
Primary Routes of Entry:
Eye contact, skin contact/absorption, and ingestion.
Signs and Symptoms of Overexposure:
Irritation to the eyes, nose, throat, or respiratory tract.
Target Organ Effects:
No data available.
Potential Health Effects:
Eyes:
Exposure may cause slight irritation.
Skin:
Prolonged or repeated skin contact may cause irritation.
Ingestion:
MATERIAL SAFETY DATA SHEET
PRODUCT NAME: GROUT SEALER CH05GL
Page 2 of 4
This material may be harmful if swallowed.
Inhalation:
Vapor or mist may cause irritation.
Reproductive/Developmental Information:
No data available.
Carcinogenicity:
NTP: Known 鈥? No; Anticipated 鈥? No OSHA: No IARC: No
Long term effects:
No data available.
SECTION 4: FIRST AID MEASURES
Eyes:
Flush eyes with water for 15 minutes. If irritation persists, call a physician.
Skin:
Flush skin with plenty of water for 15 minutes. If irritation persists, call a physician. Remove
contaminated clothing and wash before reuse.
Ingestion:
If swallowed, do not induce vomiting. Never give anything by mouth to an unconscious person.
Seek medical attention immediately.
Inhalation:
Remove to fresh air. If symptoms persist, seek immediate medical attention.
SECTION 5: FIRE FIGHTING MEASURES
Flash Point: >200掳 (Closed cup)
No data available.
Autoignition Temperature:
No data available.
Flammable Properties:
During a fire, thermal decomposition may generate oxides of carbon and nitrogen.
Extinguishing Media:
In case of fire, use water fog, dry chemical, CO , or 鈥渁lcohol鈥? foam.
2
Fire Fighting Instructions:
Keep personnel removed from and upwind of fire. Wear full fire-fighting turn-out gear (full
Bunker gear), and respiratory protection (SCBA).
SECTION 6: ACCIDENTAL RELEASE MEASURES
Absorb with an inert material and place in a chemical waste container. Rinse the area with water.
MATERIAL SAFETY DATA SHEET
PRODUCT NAME: GROUT SEALER CH05GL
Page 3 of 4
SECTION 7: HANDLING AND STORAGE
Store in a cool, well ventilated place. Keep container closed while stored. Follow all MSDS/label
warnings even after container is emptied since emptied containers retain product residues.
SECTION 8: EXPOSURE CONTROLS / PERSONAL PROTECTION
Eye Protection:
Wear chemical splash goggles.
Skin Protection:
Wear chemical resistant gloves. Wear impervious clothing and boots to prevent repeated or
prolonged skin contact.
Respiratory Protection:
Good general ventilation should be sufficient to control airborne levels.
Engineering Controls:
Provide sufficient mechanical ventilation to maintain exposure below the level of overexposure.
SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES
Odor: Mild
Physical State: Liquid.
Appearance: Clear, colorless
pH: 8.5
Specific Gravity: 1.01
Boiling Point: N/E
Freezing/Melting Point: N/E
Vapor Pressure: N/E
Vapor Density: N/E
Solubility in Water: Complete
SECTION 10: STABILITY AND REACTIVITY
Stability: Stable.
Conditions to Avoid: None.
Incompatibility: None.
Hazardous Decomposition Products: None.
Hazardous Polymerization: Will not occur.
SECTION 11: TOXICOLOGICAL INFORMATION
No data available.
SECTION 12: ECOLOGICAL INFORMATION
No data available.
SECTION 13: DISPOSAL CONSIDERATIONS
Do not dispose of on the land, in surface waters, or in storm drains. Small spills and
waste may be flushed into a waste treatment sewer where local regulations permit.
MATERIAL SAFETY DATA SHEET
PRODUCT NAME: GROUT SEALER CH05GL
Page 4 of 4
Larger quantities should be collected for reuse or consigned to a licensed hazardous
waste hauler for disposal in accordance with federal, state and local regulations. All
disposal must be in accordance with all federal, state and local regulations.
SECTION 14: TRANSPORT INFORMATION
No restrictions for Ground, Air, or Maritime Transportation in accordance with 49 CFR parts
100-185.
SECTION 15: REGULATORY INFORMATION
All components are listed on TSCA.
SECTION 16: OTHER INFORMATION
This product has no established regulatory information. All regulatory information given is based
on individual components of the mixture by component number. While this information and
recommendations set forth herein are believed to be accurate and reliable, it is provided without
warranty regarding its accuracy. HYDROFORCE MANUFACTURING MAKES NO
WARRANTY WITH RESPECT HERETO AND DISCLAIMS ALL LIABILITY FROM
RELIANCE THEREON. Users must determine safe conditions for use and assume liability for
any loss, injury, damage or expense resulting from use of this product.
N/A = Not applicable N/D = Not determined N/E = Not established
|