AI TECHNOLOGY INC MATERIAL SAFETY DATA SHEET
70 Washington Road
Princeton Jct., NJ 08550 DATE OF REVISION: C 08/27/02
(609) 799-9388 fax (609) 799-9308
EMERGENCY PHONE: (609) 799-9388
E-Mail: ait@aitechnology.com
Internet: http://www.aitechnology.com
EG9095 (Mixed)
PRODUCT:
Graphite filled two component epoxy system.
PRODUCT DESCRIPTION:
SECTION I PHYSICAL DATA
Boiling Point: Not Applicable Solubility in Water: None
Vapor Pressure (mmHg): Not Applicable Specific Gravity (H 2 O=1): 2.8
VaporDensity (Air=1): Not Applicable % Volatile by Volume: 28.5%
SECTION II HAZARDOUS INGREDIENTS AS DEFINED IN 29CFR1910-1200
MATERIAL CAS NO. % OSHA PEL ACGIH TLV
Graphite 7782-42-5 40-90 10 mg/m鲁 * 2 mg/m鲁 *
Epoxy Admixture Proprietary 60-10 None Establilshed None Establilshed
NOTE: * For powders only; in adhesive product, powders are bound in adhesive and values are not applicable.
SECTION III FIRE AND EXPLOSION HAZARD DATA
Flash Point: Not Applicable
Flammable Limits (Limits In Air): LFL: None UFL: None
Extinguishing Media: Water fog, Carbon Dioxide, dry chemical.
Special Fire Fighting Equipment and Hazards: Use self-contained breathing apparatus; decomposition and
combustion products may be toxic.
SECTION IV REACTIVITY DATA
Stability: Stable
Incompatibility: Strong Acids, Strong Bases.
Hazardous Decomposition Products: Carbon Monoxide, Carbon Dioxide.
Hazardous Polymerization: None
SECTION V SPILL, LEAK, AND DISPOSAL PROCEDURES
Action to take for spills: Use appropriate equipment. Sweep up and hold for proper disposal.
Disposal Method: Burn in adequate incinerator or bury in approved landfill.
NOTE: Incineration and recovery of silver components is recommended. Consult Federal, state and local regulations for proper disposal method.
SECTION VI HEALTH HAZARD DATA
Ingestion: Low single dose oral toxicity; LD50 (Rat) > 2000 mg/Kg
Eye Contact: Minor transient irritation.
Skin Contact: Minor to no irritation. May be a weak skin sensitizer in susceptible individuals.
Skin Absorption: Not absorbed in toxic amounts.
Inhalation: Not likely to be a problem. No guide for control known.
Effects of Overexposure: Irritation, Sensitization, Dermatitis.
MSDS EG9095 (Mixed) Page 1
DATE OF REVISION: C 08/27/02
MATERIAL SAFETY DATA SHEET
SECTION VII FIRST AID - NOTE TO PHYSICIAN
Eyes: Flush eyes with warm water for at least 15 minutes; see physician.
Skin: Wash with soap and water.
Inhalation: Remove to fresh air; if breathing is difficult, give oxygen.
Ingestion: If conscious, give water, induce vomiting. Get medical attention immediately.
Note to Physician: No specific antidote known. Treat symptommatically.
SECTION VIII SPECIAL HANDING INFORMATION
Ventilation: Good general ventilation and local exhaust recommended.
Respiratory Protection: None required with good local ventilation.
Protective Gloves: Impervious gloves or use of barrier cream is recommended.
Other Protective Equipment: Not usually required.
Eye Protection: Splash-proof chemical goggles.
SECTION IX SPECIAL PRECAUTIONS AND ADDITIONAL INFORMATION
WARNING! CAUSES IRRITATION. Avoid contact with eyes, skin or clothing. Avoid breathing vapor,, mist or spray.
Use with good ventilation. wash after handling, and before eating, drinking or smoking. Store in cool, dry area in
closed containers.
EPA SARA Title III Section 313 (40 CFR 372) Toxic Chemicals present in quantities greater than the "de minimis"
level are: None
All ingredients in this product are on the Toxic Substances Control Act (TSCA) inventory or are not required to be listed.
No ingredient in this product is known to be carcinogenic.
Ingredients listed on the New Jersey "RIGHT TO KNOW" substance list: None
SECTION X ADDITIONAL REGULATORY INFORMATION
THESE DATA ARE OFFERED IN GOOD FAITH AND BELIEVED TO BE ACCURATE AS OF THE DATE OF REVISION SHOWN ABOVE. NO
WARRANTY, EITHER EXPRESSED OR IMPLIED, IS HEREBY MADE. THE RECOMMENDED INDUSTRIAL HYGIENE AND SAFE HANDLING
PROCEDURES ARE BELIEVED TO BE GENERALLY APPLICABLE. HOWEVER, EACH USER SHOULD REVIEW THESE
RECOMMENDATIONS IN THE SPECIFIC CONTEXT OF THE INTENDED USE AND DETERMINE WHETHER THEY ARE APPROPRIATE. IT
IS THE RESPONSIBILITY OF THE USER TO COMPLY TO ALL APPLICABLE FEDERAL, STATE AND LOCAL LAWS.
MSDS EG9095 (Mixed) Page 2
|