Material Safety Data Sheet
Revision date:
Print Date: 12/12/2007
Version: 0
1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING
Product name: High Pure FFPE RNA Micro Kit
Product number: 05114403001
Business area: Roche Applied Sciences
Product line: None Identified
Supplier: Emergency telephone number:
Roche Diagnostics Corporation CHEMTREC:
9115 Hague Road 1-800-424-9300 (U.S. or Canada)
Indianapolis, IN 46250 1-703-527-3887 (International)
Site Phone Number: 1-800-428-5074
2. COMPOSITION/INFORMATION ON INGREDIENTS
Description 1: Lysis/ Binding Buffer
Components CAS Number Weight % OSHA PEL: OSHA STEL: ACGIH TLV: ACGIH STEL:
Triton X-100 9002-93-1 20-30 NA NA NA NA
Guanidine Hydrochloride 50-01-1 50 - 60 NA NA NA NA
Description 2: Proteinase K
Components CAS Number Weight % OSHA PEL: OSHA STEL: ACGIH TLV: ACGIH STEL:
Proteinase K 39450-01-6 99-100 NA NA NA NA
Description 3: Inhibitor Removal Buffer
Components CAS Number Weight % OSHA PEL: OSHA STEL: ACGIH TLV: ACGIH STEL:
Guanidine Hydrochloride 50-01-1 40-50 NA NA NA NA
Description 4: All other bottles not specified above
Components CAS Number Weight % OSHA PEL: OSHA STEL: ACGIH TLV: ACGIH STEL:
No hazardous components >1%, NONE NA NA NA NA NA
>0.1% carcinogen
3. HAZARDS IDENTIFICATION
Emergency Overview
NFPA Ratings:
Lysis/ Binding Buffer and Inhibitor Removal Buffer Health= 2 Flammability= 0 Reactivity= 0 Special= I, H
Proteinase K Health= 1 Flammability= 0 Reactivity= 0 Special= I, S
Other bottles not specified above Health= 0 Flammability= 0 Reactivity= 0
Special Definitions: A=Allergen CA=Carcinogen CO=Corrosive F=Flammable H=Harmful I=Irritant Ox=Oxidizer PB=Potential Biohazard
R=Reproductive S=Sensitizer T=Toxic T+=Highly Toxic W=Water Reactive
Principle routes of exposure: Ingestion, skin and/or eye contact
Inhalation: Avoid breathing dust. Proteinase K may cause asthmatic attacks due to allergic sensitization of the
respiratory tract.
Ingestion: Ingestion may cause gastrointestinal irritation, nausea, vomiting and diarrhea
Skin contact: Bottles Lysis/ Binding Buffer and Inhibitor Removal Buffer. Irritating to skin. Proteinase K may cause
allergic skin reaction.
Eye contact: Bottles Lysis/ Binding Buffer and Inhibitor Removal Buffer. Avoid contact with skin and eyes. Contact may
cause severe irritation. Other bottles may cause eye irritation.
Sensitization or Odor threshold: Proteinase K may cause sensitization.
Medical conditions aggravated by Persons with pre-existing skin disorders, eye problems, impaired liver, kidney, or respiratory function may
exposure: be more susceptible to the effects of the substance.
Additional information: None
4. FIRST AID MEASURES
Inhalation: Consult a physician. Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult,
give oxygen
Skin contact: Rinse with plenty of water. If skin irritation persists, call a physician. Remove and wash contaminated
clothing before re-use
Ingestion: Consult a physician. Do not induce vomiting without medical advice
Eye contact: In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice
Notes to physician: None determined
5. FIRE-FIGHTING MEASURES
Suitable extinguishing media: Use dry chemical, CO2, water spray or `alcohol` foam
Unusual hazards: None known
Special protective equipment for Wear self contained breathing apparatus for fire fighting if necessary
firefighters:
6. ACCIDENTAL RELEASE MEASURES
Personal precautions: Use personal protective equipment. Evacuate personnel to safe areas
Environmental precautions: Prevent further leakage or spillage if safe to do so. Prevent product from entering drains.
Methods for cleaning up: Never return spills in original containers for re-use. Sweep up or vacuum (if powder) or soak up with inert
absorbent material (if liquid), then place into a suitable clean, dry, closed container, and label for disposal
7. HANDLING AND STORAGE
Handling: Protect from contamination. Wear personal protective equipment
Storage: No special precautions required
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Engineering measures: Ensure adequate ventilation, especially in confined areas.
Personal Protective Equipment
Respiratory protection: Respiratory protection is not required under normal use of this product. If respiratory protection is needed,
follow the OSHA regulation, 29CFR1910.134. Always use a NIOSH approved respirator when necessary
Hand protection: Wear appropriate protective gloves to prevent skin contact. Replace torn or punctured gloves promptly
Skin and body protection: Wear appropriate body protection to prevent skin contact
Eye protection: Wear appropriate eye protection to prevent eye contact
Hygiene measures: Avoid contact with skin, eyes and clothing
9. PHYSICAL AND CHEMICAL PROPERTIES
pH: Lysis/ Binding Buffer pH = 4.4; Inhibitor Removal Buffer, Wash Buffer, and Elution Buffer pH = 6.6 to 7.5
Physical state: Bottles of Lysis/ Binding Buffer, Inhibitor Removal Buffer, Wash Buffer, and Elution Buffer are liquid.
Bottles of Poly (A), Lyo, MBF and Proteinase K, rec. are solid.
10. STABILITY AND REACTIVITY
Stability: Stable under recommended storage conditions
Polymerization: Not applicable
Hazardous decomposition products: Carbon oxides
Materials to avoid: Strong acids and strong bases. Strong oxidising agents
11. TOXICOLOGICAL INFORMATION
Product number: 05114403001 Page 2 of 4
Product name: High Pure FFPE RNA Micro Kit
11. TOXICOLOGICAL INFORMATION
Components NIOSH - NIOSH Pocket Guide -
Selected LD50s and LC50s: Target Organs:
Triton X-100 =1800 mg/kg Oral LD50 Rat
Guanidine Hydrochloride =1120 mg/kg Oral LD50 Rat
=5.319 mg/L Inhalation LC50 Rat 4h
Components NIOSH - NIOSH Pocket Guide -
Selected LD50s and LC50s: Target Organs:
Guanidine Hydrochloride =1120 mg/kg Oral LD50 Rat
=5.319 mg/L Inhalation LC50 Rat 4h
Inhalation: No additional data available
Skin: No additional data available
Oral: No additional data available
Mutagenic effects: No data is available on the product itself
Reproductive toxicity: No data is available on the product itself
Carcinogenic effects:
12. ECOLOGICAL INFORMATION
Bioaccumulation: Not determined
Aquatic toxicity: No data is available on the product itself
Ecotoxicity effects: No data is available on the product itself
U.S. EPA, RCRA, CERCLA, SARA, or DGC information on persistent, bioaccumulative, and toxic chemicals (PBTs):
The following chemicals are listed under the U.S. EPA regulations of RCRA, CERCLA, SARA, or DGC:
13. DISPOSAL CONSIDERATIONS
Waste from residues / unused products: Waste disposal must be in accordance with appropriate Federal, State, and local regulations. This product,
if unaltered by use, may be disposed of by treatment at a permitted facility or as advised by your local
hazardous waste regulatory authority. Residue from fires extinguished with this material may be
hazardous
14. TRANSPORT INFORMATION
Is product hazardous to ship? No
DOT
Proper shipping name: None
UN Number: Not applicable Hazard class: Not applicable Subsidiary risk: Not applicable Packing group: Not applicable
ICAO/IATA
Proper shipping name: None
UN Number: Not applicable Hazard class: Not applicable Subsidiary risk: Not applicable Packing group: Not applicable
15. REGULATORY INFORMATION
U.S. Regulations:
U.S. CERCLA/SARA/TSCA Regulatory Information: The following chemicals are listed under the following TSCA/SARA/CERCLA lists. Refer to
TSCA regulation if you need a definition for acronyms that may be shown in the TSCA Inventory field in the table below
Components CERCLA/SARA 302 CERCLA/SARA 304 SARA 313 TSCA Inventory
RQ and TPQ RQ Emission reporting
(40 CFR 355, App.A) (40 CFR Table 302.4)
Triton X-100 Listed
Guanidine Hydrochloride Listed
Product number: 05114403001 Page 3 of 4
Product name: High Pure FFPE RNA Micro Kit
Components CERCLA/SARA 302 CERCLA/SARA 304 SARA 313 TSCA Inventory
RQ and TPQ RQ Emission reporting
(40 CFR 355, App.A) (40 CFR Table 302.4)
Guanidine Hydrochloride Listed
U.S. Clean Water Act (CWA)/ California The following chemicals are listed under the CWA and/or California Proposition 65:
Proposition 65:
Canadian Regulations:
Canada DSL Inventory List - This product does not comply with DSL
Canada NDSL Inventory List - This product does not comply with NDSL
16. OTHER INFORMATION
Reason for revision: Not applicable
References: None
Additional advice: None
Prepared by: Roche Diagnostics, Health & Safety Department, MSDS Contact: 317-521-7425 or 317-521-7505
The information, data and recommendations contained herein are based upon information believed by Roche Diagnostics Corporation, after reasonable investigation and
research, to be accurate; however, Roche Diagnostics Corporation does not warrant the accuracy of this information. All materials and mixtures may present unknown
hazards and should be used with caution. When necessary or appropriate, independent opinions regarding the risk of handling or exposure should be obtained from trained
professionals. Roche Diagnostics Corporation disclaims any warranty against patent infringement and the implied warranties of merchantability and fitness for a particular
purpose. Customer's sole and exclusive remedy shall be replacement of the product or return of the product and refund of the purchase price, at Roche Diagnostics
Corporation's option. In no case shall Roche Diagnostics Corporation be liable for incidental or consequential damages, including lost profits.
End of Safety Data Sheet
Product number: 05114403001 Page 4 of 4
Product name: High Pure FFPE RNA Micro Kit
|