LERNER LABORATORIES -- EA 50
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CCNCL
MSDS NAME: EA 50
Responsible Party
Name: LERNER LABORATORIES
Address: 171 INDUSTRY DR
City: PITTSBURGH PA 15275
Info Phone: 800-253-7637
Emergency Phone Number: 800-424-9300 (CHEMTREC)
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: LERNER LABORATORIES
Address: 171 INDUSTRY DRIVE
City: PITTSBURGH PA 15275
Phone: 800-253-7637/800-424-9300(CHEMTREC)
=======================================================
Ingredients
=======================================================
Cas: 1343-93-7
Name: PHOSPHOTUNGSTIC ACID
% Wt: <1
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 64-19-7
RTECS #: AF1225000
Name: ACETIC ACID; (GLACIAL ACETIC ACID) (CERCLA). LD50:(ORAL,RAT) 3530 MG/KG.
OSHA PEL: 10 PPM
ACGIH TLV: 10 PPM;15 STEL
EPA Rpt Qty: 5000 LBS
DOT Rpt Qty: 5000 LBS
------------------------------
Name: ING 4:YLIDENE) (M-SULFOBENZYL)-, HYDROXIDE, INNER SALT, DISODIUM SALT;
(LIGHT GREEN SF, YELLOWISH)
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
-----------------------------
Cas: 67-56-1
RTECS #: PC1400000
Name: METHANOL; (METHYL ALCOHOL) (SARA 313) (CERCLA). LD50:(ORAL,RAT) 5628
MG/KG.
OSHA PEL: 200 PPM, S
ACGIH TLV: 200 PPM;250 STEL, S
EPA Rpt Qty: 5000 LBS
DOT Rpt Qty: 5000 LBS
------------------------------
Cas: 107-21-1
RTECS #: KW2975000
Name: ETHYLENE GLYCOL (SARA 313) (CERCLA). LD50:(ORAL,RAT) 4700 MG/KG.
OSHA PEL: N/K (FP N)
ACGIH TLV: 50 PPM, VAPOR, C
EPA Rpt Qty: 1 LB
DOT Rpt Qty: 1 LB
------------------------------
Cas: 548-26-5
RTECS #: DH6832500
Name: BENZOIC ACID, 2-(2,4,5,7-TETRABROMO-6-HYDROXY-3- OXO-3H-XANTHEN-9-YL)-,
DISODIUM SALT; (EOSYN-Y)
% Wt: <1
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 5141-20-8
RTECS #: BQ4900000
Name: AMMONIUM, ETHYL(4-(P-(ETHYL(M-SULFOBENZYL)AMINO)-
ALPHA-(P-SULFOPHENYL)BENZENYLIDENE)- 2,5-CYCLOHEXADIEN-1-
% Wt: <1
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: SEE INGREDIENTS.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: INHALATION OF HIGH CONCENTRATIONS OF VAPORS MAY IRRITATE
RESPIRATORY TRACT AND PRODUCE NARCOSIS. LIQUID CONTACT CAUSES EYE IRRITATION
AND DRYING OF SKIN. ABSORPTION THRU SKIN FROM PROLONGED OR REPEATE D
EXPOSURES CAUSE TOXIC EFFECTS. INGESTION CAUSES DIZZINESS, HEADACHES, VISUAL
DISTURBANCES AND (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZ:POSSIBLY DEATH. LIGHT GREEN, SF
YELLOWISH IS A REPORTED CARCINOGEN.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: EYES:IMMEDIATELY FLUSH W/LUKEWARM WATER FOR AT LEAST 15 MINUTES.
SKIN:REMOVE CONTAMINATED CLOTHING. WASH SKIN W/MILD SOAP & WATER. FLUSH
15 MINUTES W/WATER. INHAL:REMOVE PERSON TO FRESH AIR. ADMINISTE R OXYGEN OF
CPR AS NEEDED. INGEST:CONTACT POISON CONTROL & OBTAIN MEDICAL ATTENTION
IMMEDIATELY.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: ELIMINATE ALL SOURCES OF IGNITION. SOAK UP SMALL
SPILLS W/PAPER TOWELS. EVAPORATE IN A FUME HOOD. BURN PAPER TOWELING. LARGE
SPILLS SHOULD BE CONTAINED & COLLECTED FOR DISPOSAL.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: INCINERATE WHERE PERMITTED BY FEDERAL, STATE &
LOCAL REGULATIONS. INCINERATOR SHOULD BE EQUIPPED W/AFTERBURNER &
SCRUBBER.
Handling And Storage Precautions: STORE CONTAINERS IN AREAS APPROVED FOR
FLAMMABLE. DO NOT HANDLE OR STORE NEAR HEAT, SPARKS, FLAMES OR STRONG
OXIDANTS.
Other Precautions: KEEP CONTAINERS CLOSED WHEN NOT IN USE.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: OC
Flash Point Text: 76.0F,24.4C
Extinguishing Media: USE CARBON DIOXIDE OR DRY CHEMICAL FOR SMALL FIRES. USE
ALCOHOL TYPE FOAM FOR LARGE FIRES.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N). DO NOT USE ORDINARY FOAM. APPLICATION OF WATER FOG/SPRAY
WILL AID IN KEEPING FIRE-EXPOS MATLS COOL.
Unusual Fire/Explosion Hazard: FLAMMABLE LIQUID. VAPORS ARE HEAVIER THAN AIR
& TRAVEL ALONG GROUND TO AN IGNITION SOURCE & FLASH BACK TO VAPOR
SOURCE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: IF AIRBORNE CONCENTRATION IS BEYOND ACCEPTABLE LEVEL,
USE APPROPRIATE NIOSH APPROVED RESPIRATOR.
Ventilation: GENERAL ROOM VENTILATION IS USUALLY ADEQUATE. MECHANICAL
VENTILATION SHOULD BE EXPLOSION PROOF.
Protective Gloves: CHEMICAL RESISTANT GLOVES.
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI
DESIGN CRITERIA (FP N). USE OTHER CLOTHING TO PREVENT SKIN CONTACT.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: 204F,96C
Vapor Density: >1
Spec Gravity: 0.918
Evaporation Rate & Reference: >1 (BUTYL ACETATE=1)
Solubility in Water: COMPLETE
Appearance and Odor: DARK GREEN W/PINK CAST; CHARACTERISTIC ALCOHOL ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: AVOID SOURCES OF IGNITION, SUCH AS HEAT, SPARKS &
FLAMES.
Materials To Avoid: STRONG OXIDANTS.
Hazardous Decomposition Products: INCOMPLETE COMBUSTION MAY PRODUCE CARBON
DIOXIDE &/OR CARBON MONOXIDE.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: EA 50
Company: LERNER LABORATORIES
Street: 171 INDUSTRY DRIVE
City: PITTSBURGH PA
Zipcode: 15275
Health Emergency Phone: 800-424-9300 (CHEMTREC)
Label Required IND: Y
Date Of Label Review: 10/08/1996
Status Code: C
Label Date: 10/08/1996
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Moderate
Fire Hazard: Severe
Reactivity Hazard: None
Hazard And Precautions: FLAMMABLE. ACUTE:INHALATION OF HIGH CONCENTRATIONS OF
VAPORS MAY IRRITATE RESPIRATORY TRACT AND PRODUCE NARCOSIS. LIQUID CONTACT
CAUSES EYE IRRITATION AND DRYING OF SKIN. ABSORPTION THRU SKIN FROM PRO
LONGED OR REPEATED EXPOSURES CAUSE TOXIC EFFECTS. INGESTION CAUSES DIZZINESS,
HEADACHES, VISUAL DISTURBANCE AND DAMAGE, CENTRAL NERVOUS SYSTEM DEPRESSION
AND POSSIBLY DEATH. CHRONIC:POSSIBLE CARCINOGE N.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.