LOCTITE CORP -- PERMATEX CHAIN LUBE, 122GA
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CCSDV
MSDS NAME: PERMATEX CHAIN LUBE, 122GA
Responsible Party
Name: LOCTITE CORP
Address: 4450 CRANWOOD PARKWAY
City: CLEVELAND OH 44128
Info Phone: 216-663-3011
Emergency Phone Number: 800-255-3924
Preparer's Name: JEAN TOBBE
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: LOCTITE CORP
Address: 705 N MT RD
City: NEWINGTON CT 06111
Phone: 312-689-6200
Name: LOCTITE CORP AUTOMOTIVE AND CONSUMER GROUP
Address: 4450 CRANWOOD COURT
City: CLEVELAND OH 44128-4004
Phone: 216-663-3011
=======================================================
Ingredients
=======================================================
Cas: 71-55-6
RTECS #: KJ2975000
Name: ETHANE, 1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE) (SARA 313) (CERCLA)
% Wt: 35-40
OSHA PEL: 350 PPM
ACGIH TLV: 350 PPM;450 STEL
EPA Rpt Qty: 1000 LBS
DOT Rpt Qty: 1000 LBS
Ozone Depleting Chemical: 1
------------------------------
Cas: 8008-20-6
RTECS #: OA5500000
Name: KEROSENE
% Wt: 10-15
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 74-98-6
RTECS #: TX2275000
Name: PROPANE; (PROPANE PROPELLANT)
% Wt: 5-10
OSHA PEL: 1000 PPM
ACGIH TLV: ASPHYXIANT
------------------------------
Name: PETROLEUM OIL
% Wt: 40-45
OSHA PEL: 100 PPM (MFR)
ACGIH TLV: 100 PPM (MFR)
-----------------------------
Name: ADDITIVES
% Wt: TRACE
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
-----------------------------
RTECS #: 9999999VO
Name: VOLATILE ORGANIC COMPOUNDS: 19.4% THEORETICAL.
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: CHLOROCARBON MATLS HAVE PRDCD SENSIT OF MYOCARDIUM TO
EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS.
ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR
LIFE-SUSTAININ G USES IN HUMANS ACUTELY/CHRONICALLY EXPOS TO CHLOROCARBONS
(FP N). MAY CAUSE IRRIT TO SKIN & UPPER (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZ:RESP TRACT. MAY CAUSE HDCH, NAUS,
DIZZ. VAPS IN HIGH CONCS ARE ANESTH. 1,1,1-TRICHLOROETHANE:EYE IRRIT. IT IS
MOD TOX BY INHAL. IT HAS BEEN SHOWN TO CAUSE REPRO EFTS & LIVER DMG IN
EXPTL ANIM ALS ON PRLNG INHAL. HOWEVER, IT IS MFR'S BEST TECHNICAL JUDGEMENT
THAT W/PROPER PRECS, NORMAL USE OF THIS PROD (SUPDAT)
Medical Cond Aggravated By Exposure: NONE KNOWN.
First Aid: INGEST:DO NOT INDUCE VOMITING. CALL MD IMMEDIATELY. INHAL:REMOVE TO
FRESH AIR. CALL MD. SKIN:WASH THOROUGHLY W/LARGE QUANTITIES OF SOAP &
WATER. EYES:FLUSH W/WATER FOR AT LEAST 15 MINUTES. CALL MD.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: REMOVE SOURCES OF IGNITION. VENTILATE AREA WELL.
REMOVE RESIDUE W/INERT ABSORBENT.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS (FP N). DO NOT INCINERATE. DISPOSE FOLLOWING EPA & LOCAL
REGULATIONS FOR DISPOSAL OF PRESSURIZED CONTAINERS.
Handling And Storage Precautions: DO NOT STORE ABOVE 120F. DO NOT EXPOSE TO
DIRECT SUNLIGHT. DO NOT PUNCTURE. DO NOT SPRAY NEAR FIRE OR OPEN FLAME.
Other Precautions: NO SMOKING IN AREA OF USE. DO NOT USE IN GENERAL VICINITY OF
ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV RADIATION MAY
CAUSE THE FORMATION OF HCL &/OR PHOSGENE (FP N).
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: TOC
Flash Point Text: <0F,<-18C
Extinguishing Media: CO*2, FOAM, DRY CHEMICAL.
Fire Fighting Procedures: WEAR NIOSH APPROVED PRESSURE DEMAND SCBA & FULL
PROTECTIVE EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE HCL
& PHOSGENE (FP N). DO NOT SPRAY NEAR OPEN FLAME. HEAT/SUNLIGHT MAY CAUSE
BURSTING.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF
CONCERN (FP N).
Ventilation: SUFFICIENT TO MAINTAIN VAPOR CONCENTRATION BELOW TLV.
Protective Gloves: RUBBER OR PLASTIC GLOVES.
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI
DESIGN CRITERIA (FP N).
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: BP:<0F,<-18C (PROPELLANT). VP:COMPRESSED
GASES:PROPANE - PRESSURE AT ROOM TEMPERATURE:55 PSIG. EFTS OF OVEREXP:DOES
NOT POSE THESE HAZARDS. LIQUID KEROSENE:MODERATELY IRRITATING TO SKIN &
EYES. IT IS ALSO TOXIC BY INGESTION.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: SUPP DATA
Vapor Pres: SUPP DATA
Vapor Density: HVR/AIR
Solubility in Water: INSOLUBLE
Appearance and Odor: CLEAR LIQUID SPRAY; MILD ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: DO NOT STORE ABOVE 120F.
Materials To Avoid: NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products: PHOSGENE (FP N). HAZARDOUS PRODUCTS FORMED BY
FIRE OR THERMAL DECOMPOSITION:OXIDES OF CARBON, HYDROGEN CHLORIDE.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: PERMATEX CHAIN LUBE, 122GA
Company: LOCTITE CORP
Street: 705 N MT RD
City: NEWINGTON CT
Zipcode: 06111
Health Emergency Phone: 800-255-3924
Label Required IND: Y
Date Of Label Review: 11/18/1996
Status Code: C
Label Date: 11/18/1996
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Slight
Fire Hazard: Severe
Reactivity Hazard: None
Hazard And Precautions: EXTREMELY FLAMMABLE. ACUTE:INHALATION OF VAPORS MAY
CONTRIBUTE TO THE OCCURRENCE OF IRREGULAR HEARTBEAT (FP N). SKIN:IRRITATION.
EYES:IRRITATION. INHALATION:HEADACHE, NAUSEA, DIZZINESS, IRRITATION. IN
GESTION:MODERATELY TOXIC. CHRONIC:INHALATION:REPRODUCTIVE EFFECTS AND LIVER
DAMAGE.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.