Search   
MSDS  : CATALYST SOLUTION B-5, HD5005
CAS  :
NAME  : *** proprietary ***
DEXTER ELECTRONICS MATERIALS -- CATALYST SOLUTION B-5, HD5005
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CCSFD
MSDS NAME: CATALYST SOLUTION B-5, HD5005
Responsible Party
Name: DEXTER ELECTRONICS MATERIALS
Address: 15051 EAST DON JULIAN RD
City: INDUSTRY CA 91746-1282
Info Phone: 818-968-6511
Emergency Phone Number: 818-916-9107;800-424-9300(CHEMTREC)
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: DEXTER CORP DEXTER ELECTRONIC MATERIALS
Address: 15051 E DON JULIAN RD
City: INDUSTRY CA 91746-1282
Phone: 626-968-6511
Name: DEXTER CORP THE DEXTER ELECTRONIC MATERIAL DIV
Address: 211 FRANKLIN ST.
City: OLEAN NY 14760-1297
Phone: 716-372-6300/6309
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ANIMAL STUDIES HAVE CLEARLY DEMONSTRATED DOSE-RELATED
ADVERSE EFTS ON CNS, BLOOD FORMING TISS, BLOOD, KIDNEYS & LIVER ASSOC
W/ADMIN OF ETHYLENE GLYCOL MONOBUTYL ETHER (EGBE). (EXTRACTED FROM DHHS (NIO
SH) PUB NO. 90-118) (FP N). ACUTE:EYE:SEV IRRIT. SKIN:MOD IRRIT. INHAL:MOD
IRRIT TO LUNGS. INGEST:SEV (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT.
Signs And Symptions Of Overexposure: HLTH HAZ:IRRIT TO MOUTH, STOM &
DIGESTIVE TRACT. MAY CAUSE VOMIT, DROOLING/PAIN. MAY BURN MOUTH, THROAT,
& STOM. TARGET ORGANS:INGREDS MAY BE TOX TO FOLLOWING ORGANS:SKIN, EYES,
LUNGS, MUC MEMB. TOX I NFO:EYE:CONJ IRRIT & POSS CORNEAL BURNSDUE TO
ALKALINE AMINES PRESENT. SKIN:MILD IRRIT & DRYNESS. GLYCOL ETHER (SUPDAT)
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: EYE:FLUSH W/FLOWING WATER FOR @ LST 15 MINS. BLINK EYES FREQUENTLY.
RPT FLUSHING IF BURNING/PAIN PERSISTS. IF PROBLEMS CONTINUE GET MED ATTN.
SKIN:RINSE IMMED W/PLENTY OF WATER. REMOVE CONTAMD CLTHG. IF PROBLEMS
PERSIST GET IMMED MED ATTN.DO NOT APPLY LOTIONS/CREAMS W/OUT ADVICE OF
PHYS/POIS CTR. INHAL:REMOVE VICTIM TO FRESH AIR. IF BRTHG IS DFCLT GET IMMED
MED ATTN. IF NOT BRTHG GIVE
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: CLEAN-UP:REMOVE IGNIT SOURCES. PROVIDE ADEQ VENT
&/OR PERSONAL PROT EQUIP (SEE SECTION 8). ABSORB SPILL W/INERT MATL (E.G.
DRY SAND/EARTH), THEN PLACE IN CHEM WASTE CNTNR. PVNT RUNOFF TO STORM SEWERS,
DITCHES & OTHER PATHWAYS TO SOIL & WATERWAYS.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: LEGAL DISPOSITION OF WASTES IS RESPONSIBILITY OF
OWNER/GENERATOR OF WASTE. APPLIC FED, STATE &/OR LOCAL REGS MUST BE
FOLLOWED DURING TREATMENT, STOR/DISP OF WASTE CONTAINING THIS PROD. IT IS REC
THAT FOLLOWING PRIORITY HIERARCHY BE USED WHEN
Handling And Storage Precautions: DO NOT STORE WITH INCOMPATIBLE MATERIALS.
STORE CONTAINERS UPRIGHT. KEEP AWAY FROM HEAT AND FLAME.
Other Precautions: AVOID BREATHING FUMES. DO NOT SPLASH OR SPILL.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: COC
Flash Point Text: 110F,43C
Extinguishing Media: CARBON DIOXIDE, FOAM, DRY CHEMICALS, WATER SPRAY OR FOG.
Fire Fighting Procedures: WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: HEAT IN EXCESS OF FLASHPOINT, OPEN FLAME, OR
STORAGE WITH INCOMPATIBLE MATERIALS AS LISTED IN STABILITY AND REACTIVITY.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NO RESP IS REQD IF INGRED EXPOS LIMS ARE NOT EXCEEDED.
AN NIOSH APPRVD (29 CFR 1910.134 USA DEPT OF LABOR), AIR PURIFYING, HALF-FACE
RESP W/APPROP CARTRIDGE SHOULD BE USED IF EXPOSURE LIMITS ARE EXCEE DED.
Ventilation: USE LOCAL EXHAUST VENTILATION.
Protective Gloves: CHEMICAL RESISTANT RUBBER GLOVES.
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGS
Other Protective Equipment: APRON. ANSI APPRVD EYE WASH & DELUGE SHOWER (FP N).
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: USERS OF "L" VERSION OF SHOULD CONSULT "LR"
VERSION FOR ADDNL INFO (FP N). EFTS OF OVEREXP:CAN BE ABSORBED FROM DERMAL
EXPOS. ABSORP OF TOX AMTS THRU SKIN IS UNLIKELY UNDER ORDINARY CNDTNS OF IND
UST USE. INHAL:EXPOS TO HIGH CONCS CAN CAUSE HDCH, DIZZ,
NAUS/SHORTNESS/BREATH. CHRONIC EXPOS MAY CAUSE BRONCH/
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: 300F,149C
Evaporation Rate & Reference: NOT KNOWN
Solubility in Water: NOT KNOWN
Appearance and Odor: AMBER LIQUID, AMMONIA ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: EXTREME TEMPERATURES.
Materials To Avoid: OXIDIZING AGENTS.
Hazardous Decomposition Products: NONE.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
Other Information: VOLATILE ORGANIC COMPOUND:BEFORE USE THIS PRODUCT MUST BE
MIXED WITH ANOTHER DEXTER PRODUCT. TO OBTAIN VOC DATA
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: CATALYST SOLUTION B-5, HD5005
Company: DEXTER CORP THE DEXTER ELECTRONIC MATERIAL DIV
Street: 211 FRANKLIN ST.
City: OLEAN NY
Zipcode: 14760-1297
Health Emergency Phone: 818-916-9107;800-424-9300(CHEMTREC)
Label Required IND: Y
Date Of Label Review: 11/15/1996
Status Code: C
Label Date: 11/15/1996
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Severe
Contact Hazard: Severe
Fire Hazard: Moderate
Reactivity Hazard: None
Hazard And Precautions: FLAMMABLE LIQUID. DO NOT INGEST. AVOID EYE CONTACT.
ACUTE:EYE CONTACT:SEVERE IRRITATION AND POSSIBLE CONJUNCTIVAL BURNS. SKIN
CONTACT:MODERATE IRRITATION AND DRYNESS. INHALATION:MODERATE LUNG IRRITATI
ON, HEADACHE, DIZZINESS, NAUSEA AND SHORTNESS OF BREATH. INGESTION:SEVERELY
IRRITATING TO AND MAY BURN MOUTH, STOMACH AND DIGESTIVE TRACT. MAY CAUSE
VOMITING, DROOLING OR PAIN. CHRONIC:ANIMAL STUDIES HAVE DEMONSTRATED DOSE
RELATED ADVERSE EFFECTS TO CNS, BLOOD FORMING TISSUE, BLOOD, LIVER AND
KIDNEYS ASSOCIATED W/ADMINISTRATION OF 2-BUTOXYETHANOL (FP N). CHRONIC
INHALATION MAY CAUSE BRONCHITIS OR EMPHESEMA.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
HYDROXYLAMINE HYDROCHLORIDE, 3% TO 50%, LC15540 5470-11-1
7732-18-5
HYDROXYLAMINE HYDROCHLORIDE, 3% TO 50%, LC15550 5470-11-1
7732-18-5
SERIES IV TONER CARTRIDGE
PERMATEX CHAIN LUBE, 122GA 71-55-6
8008-20-6
74-98-6
CATALYST SOLUTION B-5, HD5005
ETHYLENE GLYCOL, C00057 107-21-1
OXYGEN, COMPRESSED 7782-44-7
IRIDITE 14, 78658
CHEMLOK 8007 111-76-2
50-00-0
1314-13-2
POTASSIUM PERSULFATE 5%, LC20080 7727-21-1
7732-18-5
ACCUFAX CODE 70920 112945-52-5
31714-55-3
1309-37-1
9003-07-4
26655-10-7
PROFESSIONAL LINE DAWN, 08082 64-17-5
7732-18-5
PROFESSIONAL LINE DAWN, 08764 64-17-5
7732-18-5
PROFESSIONAL LINE DAWN, 08460 64-17-5
7732-18-5
PROFESSIONAL LINE DAWN, 08536 64-17-5
7732-18-5
PROFESSIONAL LINE DAWN, 08684 64-17-5
7732-18-5
PROFESSIONAL LINE DAWN, 08095 64-17-5
7732-18-5
PROFESSIONAL LINE DAWN, 08047 64-17-5
7732-18-5
PROFESSIONAL LINE DAWN, 08021 64-17-5
7732-18-5
PROFESSIONAL LINE DAWN, 08077 64-17-5
7732-18-5
C10
DRI WASH'N GUARD WATERLESS WASH & PROTECTIVE GLAZE 8008-20-6
INHIBITED RED FUMING NITRIC ACID L61 7697-37-2
10544-72-6
7664-39-3
7732-18-5
QM 1, 03384 1310-73-2
SURFACE TREATED & PROCESSED CELLULOSE FIBERS 9004-34-6
7429-90-5
7429-90-5
7439-89-6
12001-26-2
7429-90-5
OIL-PRECISION B+, 69125, CPS253000 64742-54-7
SERPIFLEX SHIELD (AEROSOL) SSA12 107-21-1
PPC DEVELOPER TYPE 1, 888455
10-100 PPM CARBON MONOXIDE, 10 PPM-2.5% (SUP DAT) 630-08-0
74-82-8
7782-44-7
7727-37-9
LUSTER-GUARD, 0918
HITEC 580 PERFORMANCE ADDITIVE
FLUOROSILICIC ACID 16961-83-4
7732-18-5
IRIDITE 14-2, 24010
E 100 ALL SOL FLUX 12125-02-9
7647-01-0
7646-85-7
RYDLYME, RID-LIME
H-7 PUT A HALT TO RUST
H-8 PUT A HALT TO RUST
H-6 PUT A HALT TO RUST
H-5 PUT A HALT TO RUST
PF
60-9800-1020-5 00-51144-14061-9, GLASS (SUPDAT) 7732-18-5
1306-38-3
HYDROSEP (BACTERIOSTATIC ADDITIVE) 18472-51-0
MANCOZEB DG 8018-01-7
7440-66-6
30525-89-4
SODIUM NITRATE
DEER-AWAY BIG GAME REPELLENT FORMULA 2104
4019 CORROSION INHIBITOR
ARGON 7440-37-1
NITROUS OXIDE 10024-97-2
ADHESIVE-CARRIER-LINER LAMINATE, 1173D
POLISH AND SEALANT, DRI WASH'N GUARD FOR (SUP DAT) 8008-20-6

Free MSDS Search ( Providing 250,000+ Material Properties )