INTERNATIONAL MARKING GROUP -- ELECTROLYTE 26
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CDTZF
MSDS NAME: ELECTROLYTE 26
Responsible Party
Name: INTERNATIONAL MARKING GROUP
Address: 206 KOSSUTH AVE
City: UTICA NY 13501
Info Phone: 315-735-7591
Emergency Phone Number: 315-735-7591
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: INTERNATIONAL MARKING GROUP
Address: 206 KOSSUTH AVE
City: UTICA KY 13501
Phone: 315-735-7591
=======================================================
Ingredients
=======================================================
Cas: 6484-52-2
RTECS #: BR9050000
Name: AMMONIUM (I) NITRATE (1:1)
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 64-19-7
RTECS #: AF1225000
Name: ACETIC ACID (CERCLA)
OSHA PEL: 10 PPM
ACGIH TLV: 10 PPM; 15 STEL
EPA Rpt Qty: 5000 LBS
DOT Rpt Qty: 5000 LBS
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE: IRRITATION OF EYES, SKIN AND RESPIRATORY SYSTEM.
AVOID INGESTION.
Explanation Of Carcinogenicity: NOT RELEVANT.
Signs And Symptions Of Overexposure: SEE HEATH HAZARDS.
Medical Cond Aggravated By Exposure: NONE IDENTIFIED.
First Aid: INGEST: CALL MD IMMEDIATELY (FP N). INHALATION: REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE OXYGEN/ARTIFICIAL RESPIRATION) (FP N). SKIN: IN CASE
OF CONTACT, IMMEDIATELY FLUSH WITH WATER. EYES: IF IN CONTACT WITH EYES,
FLUSH WITH WATER FORAT LEAST 15 MINUTES.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: WEAR APPROPRIATE PROTECTIVE CLOTHING. ABSORB WITH
VERMICULITE, PAPER, ETC AND REMOVE. FLUSH AREA WITH WATER.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE OF IN ACCORDANCE WITH ALL APPLICABLE FEDERAL,
STATE AND LOCAL ENVIRONMENTAL REGULATIONS.
Handling And Storage Precautions: KEEP CONTAINER CLOSED.
Other Precautions: NONE.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: WATER OR APPROPRIATE TO SURROUNDING AREA.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT
(FP N).
Unusual Fire/Explosion Hazard: STRONG OXIDIZER. DRIED RESIDUES EXPOSED TO HEAT
MAY EXPLODE OR ACCELERATE COMBUSTION.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NONE. USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN (FP N).
Ventilation: LOCAL EXHAUST.
Protective Gloves: NEOPRENE OR RUBBER GLOVES.
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N).
Other Protective Equipment: ANSI APPROVED EYE WASH & DELUGE SHOWER (FP N).
UNIFORM OR APRON RECOMMENDED.
Work Hygienic Practices: WASH HANDS AFTER USE.
Supplemental Safety and Health: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: >212F,>100C
Spec Gravity: 1.062 (H*2O=1)
Solubility in Water: MISCIBLE
Appearance and Odor: CLEAR/ODORLESS.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: FOR DRIED RESIDUES AVOID ORGANIC MATERIALS AND STRONG
REDUCING AGENTS.
Hazardous Decomposition Products: OXIDES OF NITROGEN.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: ELECTROLYTE 26
Company: INTERNATIONAL MARKING GROUP
Street: 206 KOSSUTH AVE
City: UTICA KY
Zipcode: 13501
Health Emergency Phone: 315-735-7591
Label Required IND: Y
Date Of Label Review: 05/15/1997
Status Code: C
Label Date: 05/15/1997
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: ACUTE: IRRITATION OF EYES, SKIN AND RESPIRATORY SYSTEM.
AVOID INGESTION. CHRONIC: NONE LISTED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.