Search   
MSDS  : FLUORESCENT LEAK SCANNER SOLUTION 1
CAS  :
NAME  : *** proprietary ***
RITCHIE ENGINEERING INC -- FLUORESCENT LEAK SCANNER SOLUTION 1
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CDVCB
MSDS NAME: FLUORESCENT LEAK SCANNER SOLUTION 1
Responsible Party
Name: RITCHIE ENGINEERING CO INC
Address: 10950 HAMPSHIRE AVE SOUTH
City: BLOOMINGTON MN 55438-2623
Info Phone: 612-943-1333
Emergency Phone Number: 800-424-9300(CHEMTREC)
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: RITCHIE ENGINEERING COMPANY INC
Address: 10950 HAMPSHIRE AVE S
City: MINNEAPOLIS MN 55438
Phone: 612-943-1300/1333
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: SEE INGRREDIENT 1
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: EYE CONTACT: CAN CAUSE MILD TO MODERATE IRRITATION. THE
SEVERITY OF REACTION DEPENDS ON DURATION OF EXPOSURE AND FIRST AID PROCEDURES
ADMINISTERED. SKIN CONTACT: IRRITATION CAN OCCUR FOLLOWING PROLONG ED OR
REPEATED CONTACT. INHALATION: UNDER NORMAL CONDITIONS OF USE, NO ADVERSE
EFFECTS ARE EXPECTED. (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZ: INGESTION: CAN CAUSE
GASTROINTESTINAL IRRITATION.
Medical Cond Aggravated By Exposure: EXPOSURE TO THIS PRODUCT IS NOT EXPECTED
TO CONTRIBUTE TO, WORSEN OR AGGRAVATE ANY EXISTING MEDICAL CONDITIONS.
First Aid: INHAL: REMOVE TO FRESH AIR. SUPPORT BRTHG (GIVE O*2/ARTF RESP) (FP
N). EYE: FLUSH W/WATER FOR AT LST 15 MIN. IF IRRIT DEVELOPS, CONSULT MD.
SKIN: WASH AFFECTED AREA W/SOAP & WATER. IF IRRIT DEVELOPS, CONSULT MD.
WASH CONTAMD CLTHG SEPARATELY BEFORE REUSE. INGEST: SEEK MED ATTN. UNLESS
ADVISED OTHERWISE, INDUCE VOMIT BY EITHER GIVING SYRUP OF IPECAC FOLLOWED BY
2 GLASSES OF WATER OR BY (SUPDAT)
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: STOP DISCHARGE AND CONTAIN MATERIAL. USE AN ABSORBENT
SUCH AS FULLER'S EARTH, CLAY OR OTHER APPROPRIATE SYNTHETIC ABSORBENT. PLACE
CONTAMINATED MATERIAL IN SUITABLE CONTAINER FOR DISPOSAL. ELIMINATE A LL
SOURCES OF IGNITION.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSAL MUST BE I/A/W FED, STATE & LOC REGS (FP
N). THE METHS OF DISPOSAL CURRENTLY AVAILABLE VARY BY LOCATION. IT IS
RECOMMENDED THAT ALTERNATIVE BE SELECTED ACCORDING TO FOLLOWING ORDER OF
PREFEREN CE BASED UPON ENVIRONMENTAL ACCEPTABILITY:
Handling And Storage Precautions: STORE IN A COOL, DRY, WELL-VENTILATED AREA.
DO NOT STORE NEAR HEAT OR IGNITION SOURCE. ALWAYS KEEP CONTAINERS TIGHTLY
CLOSED TO AVOID CONTAMINATION.
Other Precautions: HOT ORGANIC CHEMICAL VAPORS OR MSITS CAN SUDDENLY AND
WITHOUT WARNING COMBUST WHEN MIXED WITH AIR.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: PMCC
Flash Point Text: >200F,>93C
Extinguishing Media: SMALL FIRES: USE DRY CHEMICAL, CARBON DIOXIDE OR CHEMICAL
FOAM. LARGE FIRES: USE WATER SPRAY, FOG OR FOAM.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT
(FP N). AVOID USING WATER ON BURNING MATERIALS TO REDUCE SPLATTERING AND
SPREADING OF FIRE.
Unusual Fire/Explosion Hazard: MAY LIBERATE IRRITATING OR TOXIC VAPORS DURING
COMBUSTION OR DECOMPOSITION.
=======================================================
Control Measures
=======================================================
Respiratory Protection: AVOID BREATHING AVPOR AND/OR MIST. USE NIOSH APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN (FP N).
Ventilation: MAINTAIN AIRBORNE CONCS BELOW THE ESTABLISHED EXPOS LIMITS (SEE
TLV & PEL) BY PROVIDING ADEQ VENT. GENERAL
Protective Gloves: IMPERVIOUS GLOVES. BECAUSE A
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N).
Other Protective Equipment: ANSI APPROVED EYE WASH & DELUGE SHOWER (FP N). WEAR
PROTECTIVE CLOTHING.
Work Hygienic Practices: WASH THOROUGHLY AFTER HNDLG, ESP BEFORE EATING,
DRINKING, SMKNG OR USING RESTROOM FACILITIES. CONTAMD CLTHG &
Supplemental Safety and Health: USERS OF "L" VERSION SHOULD CONSULT "LR"
VERSION FOR ADDITIONAL INFORMATION (FP N). SPEC GRAV: 0.85-0.90 (H*2O=1).
FIRST AID PROC: STICKING FINGER DOWN THROAT. DO NOT GIVE ANYTHING BY MOUTH IF
PERSON DROWSY, UNCON OR HAS NO GAG REFLEX. INGEST CREATES A HIGH RISK OF
ASPIR & SUBSEQUENT CHEM PNEUM. HOWEVER,
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: >300F,>149C
Vapor Pres: <1 @ 68F
Vapor Density: >1
Spec Gravity: SUPDAT
Solubility in Water: INSOLUBLE
Appearance and Odor: DARK REDDISH LIQUID; LIKE GAS OIL
Percent Volatiles by Volume: 0
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: STABLE UNDER NORMAL CONDITIONS OF STORAGE AND
USE.
Materials To Avoid: OXIDIZING AGENTS AND REDUCING AGENTS.
Hazardous Decomposition Products: IF HEATED TO HIGH TEMPERATURES, THIS PRODUCT
MAY EMIT SMOKE, SOOT AND TOXIC FUMES (EG CARBON MONOXIDE & CARBON DIOXIDE).
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: FLUORESCENT LEAK SCANNER SOLUTION 1
Company: RITCHIE ENGINEERING COMPANY INC
Street: 10950 HAMPSHIRE AVE S
City: MINNEAPOLIS MN
Zipcode: 55438
Health Emergency Phone: 800-424-9300(CHEMTREC)
Label Required IND: Y
Date Of Label Review: 05/22/1997
Status Code: C
Label Date: 05/22/1997
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: ACUTE: EYE CONTACT: CAN CAUSE MILD TO MODERATE
IRRITATION. SKIN CONTACT: IRRITATION CAN OCCUR FOLLOWING PROLONGED OR
REPEATED CONTACT. INGESTION: CAN CAUSE GASTROINTESTINAL IRRITATION. CHRONIC:
NONE L ISTED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
ACR-BL NON-LEAD COLORS, TEC/BASE BASECOAT/ (SUPDAT)
HYTEMP 4001
AIR COMPRESSOR OIL 64742-65-0
TOLUOL 55GAL, 26-10036-09 108-88-3
HYDRATED LIME 1305-62-0
EPOXY HARDENER, SB 1223
POTASSIUM CHLORIDE, 477006
ORNAMEC 170, 677 69806-50-4
64741-89-5
71-36-3
1330-20-7
95-63-6
64742-95-6
H-D PLUS SAE 10W10
H-D PLUS SAE 20W20
H-D PLUS SAE 30
H-D PLUS SAE 40
H-D PLUS SAE 50
41R15 R-8840 NELCO RED PRI
CARBON MONOXIDE 630-08-0
PENAIR M-5572B 34590-94-8
7732-18-5
9016-45-9
1360-26-5
102-71-6
2230F IN MINERAL SPIRITS
76 DIESEL 2 LS, 01614 91-20-3
8002-05-9
68476-34-6
OXYGEN LIQUID, L-4637-D 7782-44-7
PROPYLENE, LIQUIFIED PETROLEUM GAS, LPG, L-4648-E
9449, MIRRORLAC-WB INT/EXT WATERBORNE (SUP DAT) 7732-18-5
13463-67-7
111-76-2
64642-88-7
112-34-5
21645-51-2
ALOE CARE (18 OZ), 4067
ELECTROLYTE 26 6484-52-2
64-19-7
ANCAMIDE 2050 CURING AGENT, H2050U
SPHERIGLASS SOLID GLASS SPHERES, S001-5 65997-17-3
BARCOR L-117 108-91-8
SOLDER, 50/50
HYSOL 50-206 R, XX0354 112-15-2
68333-88-0
80-05-7
12656-85-8
25068-38-6
106-89-8
34590-94-8
108-65-6
SCREW STRENGTH THREADLCKR, THDLKRMS 25608-33-7
80-15-9
109-16-0
85-68-7
PFS-727-R RUST INHIBITOR 7732-18-5
HEAVY DUTY SPOTTER & TRAFFIC LINE CLEANER
FLUORESCENT LEAK SCANNER SOLUTION 1
FLUORESCENT LEAK SCANNER SOLUTION 2
FLUORESCENT LEAK SCANNER SOLUTION 3
FLUORESCENT LEAK SCANNER SOLUTION 4
FLUORESCENT LEAK SCANNER SOLUTION 4-P
FLUORESCENT LEAK SCANNER SOLUTION 01
5-MINUTE EPOXY HARDENER, 14210
5-MINUTE EPOXY HARDENER, 14270
5-MINUTE EPOXY HARDENER, 14830
5-MINUTE EPOXY HARDENER, DA005
5-MINUTE EPOXY HARDENER, DA007
5-MINUTE EPOXY HARDENER, DA009
5-MINUTE EPOXY HARDENER, DA043
5-MINUTE EPOXY HARDENER, DA049
5-MINUTE EPOXY HARDENER, DA050
5-MINUTE EPOXY HARDENER, DC002
5-MINUTE EPOXY HARDENER, DC010
5-MINUTE EPOXY HARDENER, DC014
5-MINUTE EPOXY HARDENER, DC040

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net