DEXTER CORP -- 7901FRM POLYSHOT, NA7901
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CHXYL
MSDS NAME: 7901FRM POLYSHOT, NA7901
Responsible Party
Name: DEXTER CORP
Address: ONE DEXTER DR
City: SEABROOK NH 03874
Info Phone: 603-474-5541
Emergency Phone Number: 800-424-9300 (CHEMTREC)
Preparer's Name: KEN DECOSTA
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: DEXTER CORP THE HYSOL DIV
Address: 1 DEXTER DR
City: SEABROOK NH 03874
Phone: 603-474-5541/FAX: 603-474-5545
Name: DIVERSITY WATER TECHNOLOGIES INC
Address: LABORATORY PK 7145 PINE ST
Box: 200
City: CHAGRIN FALLS OH 44022
Phone: 216-247-5000
=======================================================
Ingredients
=======================================================
Name: NON-HAZARDOUS INGREDIENTS
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE: WARNING! MOLTEN HOT MELT ADHESIVE CAN CAUSE SEVERE
BURNS UPON CONTACT WITH SKIN. CHRONIC: NONE SPECIFIED BY MANUFACTURER.
Explanation Of Carcinogenicity: NOT RELEVANT.
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: SKIN: WASH WITH SOAP AND WATER. EYES: FLUSH WITH WATER FOR AT LEAST
15 MINUTES. INHALATION: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE OXYGEN
OR ARTIFICIAL RESPIRATION) (FP N). INGESTION: CALL MD IM MEDIATELY (FP N).
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: SWEEP UP TO AVOID ANY SLIPPING HAZARD.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE OF ACCORDING TO ALL LOCAL, STATE AND FEDERAL
LAWS.
Handling And Storage Precautions: NONE KNOWN.
Other Precautions: WARNING! MOLTEN HOT MELT ADHESIVE CAN CAUSE SEVERE BURNS
UPON CONTACT WITH SKIN.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Text: >450F,>232C
Extinguishing Media: WATER, CARBON DIOXIDE, FOAM, DRY CHEMICAL.
Fire Fighting Procedures: NONE. WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: NONE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NONE WHEN USING ADEQUATE VENTILATION. USE NIOSH
APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN (FP N).
Ventilation: RECOMMENDED WHEN HEATING.
Protective Gloves: HEAT PROTECTIVE GLOVES.
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N).
Other Protective Equipment: NOT REQUIRED. EMERGENCY EYEWASH AND DELUGE SHOWER
MEETING ANSI DESIGN CRITERIA (FP N).
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Physical/Chemical Properties
=======================================================
M.P/F.P Text: 340F,171C
Spec Gravity: 1.11
Solubility in Water: NIL
Appearance and Odor: AMBER WITH SLIGHT ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE KNOWN.
Hazardous Decomposition Products: CARBON MONOXIDE (FROM PARTIAL COMBUSTION AS
FOR MOST ORGANIC MATERIALS).
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: 7901FRM POLYSHOT, NA7901
Company: DIVERSITY WATER TECHNOLOGIES INC
Street: LABORATORY PK 7145 PINE ST
PO Box: 200
City: CHAGRIN FALLS OH
Zipcode: 44022
Health Emergency Phone: 800-424-9300 (CHEMTREC)
Label Required IND: Y
Date Of Label Review: 10/13/1998
Status Code: C
Label Date: 10/13/1998
Origination
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: None
Contact Hazard: Severe
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: ACUTE: WARNING! MOLTEN HOT MELT ADHESIVE CAN CAUSE
SEVERE BURNS UPON CONTACT WITH SKIN. CHRONIC: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.