Search   
MSDS  : PROPANE
CAS  :
NAME  :
NORLAB CALIBRATION GASES & EQU -- PROPANE
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CJPCG
MSDS NAME: PROPANE
Responsible Party
Name: NORLAB CALIBRATION GASES & EQUIPMENT
Address: 1121 W AMITY
City: BOISE ID 83705
Info Phone: 800-657-6672
Emergency Phone Number: 208-338-1643
Review Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: NORLAB CALIBRATION GASES & EQUIPMENT
Address: 1121 W AMITY
City: BOISE ID 83705
Phone: 800-657-6672
=======================================================
Item Description Information
=======================================================
=======================================================
Health Hazards Data
=======================================================
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE: INGESTION: THIS PRODUCT IS A GAS AT NORMAL
TEMPERATURE AND PRESSURE. SKIN ABSORPTION: NO EVIDENCE OF ADVERSE EFFECTS
FROM AVAILABLE INFORMATION. INHALATION: ASPHYXIANT. MODERATE CONCENTRATIONS
MAY CAUSE HEADACHE, DROWSINESS, DIZZINESS, CONFUSION, SALIVATION VOMITING,
AND UNCONSCIOUSNESS. LACK OF OXYGEN CAN CAUSE DEATH. SKIN/EYE CONTACT: NO
HARMFUL EFFECTS EXPECTED FROM VAPOR. LIQUID MAY CA USE FROSTBITE. CHRONIC: NO
EVIDENCE OF ADVERSE EFFECTS FROM AVAILABLE INFORMATION.
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS. CONTACT WITH LIQUID
MAY CAUSE FROSTBITE.
Medical Cond Aggravated By Exposure: A KNOWLEDGE OF THE AVAILABLE TOXICOLOGY
INFORMATION AND OF THE PHYSICAL AND CHEMICAL PROPERTIES OF THE MATERIAL
SUGGEST THAT OVEREXPOSURE IS UNLIKELY TO AGGRAVATE EXISTING MEDICAL
CONDITIONS.
First Aid: INGEST: THIS PROD IS A GAS AT NORM TEMP & PRESS. CALL MD IMMED
(FP N). SKIN: FOR EXPOS TO LIQ, IMMED WARM FROSTBITE AREA W/WARM WATER (NOT
TO EXCEED 105F). IN CASE OF MASSIVE EXPOS, REMOVE CLOTHING WH ILE SHOWERING
W/WARM WATER. CALL MD. INHAL: REMOVE TO FRESH AIR. GIVE ARTIFICIAL RESP IF
NOT BREATHING. GIVE OXYGEN IF BREATHING IS DIFFICULT. CALL MD. EYES: IN CASE
OF SPLASH CONTAMINATION, IMMED FLU SH THOROUGHLY W/WATER FOR AT LEAST 15
MINUTES. SEE MD, PREFERABLY AN OPHTHALMOLOGIST, IMMED. NOTES TO MD: THERE IS
NO SPECIFIC ANTIDOTE. TREATMENT OF OVEREXP SHOULD BE DIRECTED AT CONTROL OF
SYMPTOMS & CLINICAL CONDITIONS.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: FORMS EXPLOSIVE MIXTURES W/AIR. IMMED EVACUATE ALL
PERSONNEL FROM DANGER AREA. USE NIOSH APPRVD SCBA WHERE NEEDED. REMOVE ALL
SOURCES OF IGNIT IF W/OUT RISK. REDUCE VAPORS W/FOG OR FINE SPRAY. SHUT OF F
LEAK IF W/OUT RISK. VENT AREA OF LEAK/MOVE LEAKING CONTR TO WELL VENTILATED
AREA. FLAMM VAPS MAY SPREAD FROM SPILL. BEFORE WATERING AREA, ESPECIALLY
CONFINED AREAS, CHECK ATMOSPHERE W/APPROP DEVICE.
Waste Disposal Methods: PREVENT WASTE FROM CONTAMINATING SURROUNDING
ENVIRONMENT. KEEP PERSONNEL AWAY. DISCARD ANY PRODUCT, RESIDUE, DISPOSABLE
CONTAINER OR LINER IN AN ENVIRONMENTALLY ACCEPTABLE MANNER, IN FULL
COMPLIANCE W ITH FEDERAL, STATE AND LOCAL REGULATIONS.
Handling And Storage Precautions: DANGER: FLAMM, LIQUEFIED GAS UNDER PRESS. USE
PIPING & EQUIP ADEQ DESIGNED TO WITHSTAND PRESS TO BE ENCOUNTERED. MAY
FROM EXPLO MIXTS W/AIR. GROUND ALL EQUIP. ONLY USE SPARK-PROOF TOOLS &
EXPLO-PROOF EQUIP. KEEP AWAY FROM HEAT, SPKS & OPEN FLAME. STORE &
USE W/ADEQ VENT AT ALL TIMES.
Other Precautions: USE ONLY IN CLSD SYS. CLOSE VALVE WHEN NOT IN USE & WHEN
EMPTY. KEEP AWAY FROM OXIDIZING AGENTS. MIXTS: WHEN TWO/MORE GASES, OR
LIQUEFIED GASES ARE MIXED, THEIR HAZ PROPERTIES MAY COMBINE TO CREATE AD DNL,
UNEXPECTED HAZS. OBTAIN & EVALUATE SFTY INFO FOR EACH COMPONENT BEFORE
YOU PRDCE MIXT. (SUP DAT )
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: TCC
Flash Point: =-104.4C, -156.F
Autoignition Temp: =450.C, 842.F
Lower Limits: 2.1%
Upper Limits: 9.5%
Extinguishing Media: CARBON DIOXIDE, DRY CHEMICAL, WATER SPRAY OR FOG.
Fire Fighting Procedures: WEAR NIOSH APPRVD SCBA & FULL PROT EQUIP (FP N).
EVACUATE ALL PERS FROM DANGER AREA. IMMED COOL CONTRS W/WATER SPRAY FROM MAX
DIST TAKING CARE NOT TO EXTING FLAMES. REMOVE IGNIT SOURCES IF W/OUT RISK.
IF FLAMES ARE ACCIDENTALLY EXTINGUISHED, EXPLO RE-IGNIT MAY OCCUR. APPROP
MEASURES SHOULD BE TAKEN, (OTHER INFO)
Unusual Fire/Explosion Hazard: FLAMM GAS. FORMS EXPLO MIXTS WAIR &
OXIDIZING AGENTS. CONTRS MAY RUPTURE DUE TO HEAT OF FIRE. DO NOT EXTING
FLAMES DUE TO POSS OF EXPLO RE-IGNIT. FLAMM VAPS MAY SPREAD FROM SPILL. EXPLO
ATMS MAY LINGE R. BEFORE ENTERING AREA, ESP CONFINED AREAS, CHECK ATM
W/APPRVD DEVICE. (OTHER INFO)
=======================================================
Control Measures
=======================================================
Respiratory Protection: SELECT IN ACCORDANCE WITH OSHA 29 CFR 1910.134.
RESPIRATOR'S SHALL BE ACCEPTABLE TO NIOSH.
Ventilation: LOCAL EXHAUST: EXPLOSION-PROOF SYSTEM IS ACCEPTABLE. MECHANICAL
(GENERAL): INADEQUATE.
Protective Gloves: PREFERRED FOR CYL HNDLG & TO PREVENT LIQ EXPOS. WEAR
IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEMICAL WORKERS GOGGLES (FP N).
Other Protective Equipment: ANSI APPROVED EMERGENCY EYEWASH AND DELUGE SHOWER
(FP N). PROTECTIVE CLOTHING WHERE NEEDED. SELECT IN ACCORDANCE WITH OSHA, 29
CFR 1910.132 AND 1910.133.
Supplemental Safety and Health: OTHER PREC: CONSULT INDUS HYGIENIST/OTHER
TRAINED PERS WHEN YOU MAKE YOUR SFTY EVALUATION OF END PROD. REMEMBER, GASES
& LIQS HAVE PROPERTIES WHICH CAN CAUSE SERIOUS INJURY/DEATH. BE SURE TO
READ & UN DERSTAND ALL LABELS & OTHER INSTRUCTIONS SUPPLIED W/ALL
CONTRS OF THIS PROD. VAP DENS (AIR=1): 1.55 @ 20C.
=======================================================
Physical/Chemical Properties
=======================================================
Boiling Point: =-42.1C, -43.7F
B.P. Text: @ 760 MM HG
Melt/Freeze Pt: =-187.7C, -305.7F
Vapor Pres: 109 PSIG @ 21C
Vapor Density: SUP DAT
Spec Gravity: 0.5077 @ 25C (H*2O=1)
Evaporation Rate & Reference: HIGH (BUTYL ACETATE=1)
Solubility in Water: NEGLIGIBLE
Appearance and Odor: COLORLESS GAS AT NORMAL TEMPERATURE AND PRESSURE; FAINTY
DISAGREEABLE ODOR.
Percent Volatiles by Volume: 100
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: SEE STORAGE/HANDLING AND OTHER PRECAUTIONS
SECTIONS.
Materials To Avoid: OXIDIZING AGENTS, CHLORINE DIOXIDE.
Hazardous Decomposition Products: THERMAL DECOMPOSITION OR BURNING MAY PRODUCE
CARBON MONOXIDE/CARBON DIOXIDE.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NONE CURRENTLY KNOWN.
=======================================================
Toxicological Information
=======================================================
=======================================================
Other Information
=======================================================
Other Information: FORMULA: C3H8. SYNONYMS: DIMETHYLMETHANE, PROPYL HYDRIDE,
PROPYLDIHYDRIDE. CHEMICAL FAMILY: ALKANO. MOLECULAR WT: 44,096. TRADE NAME:
LIQUEFIED PETROLEUM GAS. FIRE FIGHT PROC: E.G. TOTAL EVACUATION. A PPROACH
W/EXTREME CAUTION. STOP FLOW OF GAS IF W/OUT RISK WHILE CONTINUING COOLING
WATER SPRAY. REMOVE ALL CONTRS FROM AREA OF FIRE IF W/OUT RISK. ALLOW FIRE TO
BURN OUT. ON SITE FIREFIGHTERS MUST COM PLY W/OSHA 29 CFR 1910.186.
FIRE/EXPLO HAZ: NO PART OF A CONTR SHOULD BE SUBJECTED TO TEMP >52C
(APPROX 126F). MOST CONTRS ARE PROVIDED W/PRESS RELIEF DEVICE DESIGNED TO
VENT CONTENTS WHEN THEY ARE EX POSED TO ELEVATED TEMPS.
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: PROPANE
Assigned IND: Y
Company: NORLAB CALIBRATION GASES & EQUIPMENT
Street: 1121 W AMITY
City: BOISE ID
Zipcode: 83705
Health Emergency Phone: 208-338-1643
Label Required IND: Y
Date Of Label Review: 10/12/1999
Status Code: A
Origination Code: G
Hazard And Precautions: ACUTE: INGESTION: THIS PRODUCT IS A GAS AT NORMAL
TEMPERATURE AND PRESSURE. SKIN ABSORPTION: NO EVIDENCE OF ADVERSE EFFECTS
FROM AVAILABLE INFORMATION. INHALATION: ASPHYXIANT. MODERATE CONCENTRATIONS
MAY CAUSE HEADACHE, DROWSINESS, DIZZINESS, CONFUSION, SALIVATION VOMITING,
AND UNCONSCIOUSNESS. LACK OF OXYGEN CAN CAUSE DEATH. SKIN/EYE CONTACT: NO
HARMFUL EFFECTS EXPECTED FROM VAPOR. LIQUID MAY CA USE FROSTBITE. CHRONIC: NO
EVIDENCE OF ADVERSE EFFECTS FROM AVAILABLE INFORMATION.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
INTERSHIELD PRORECO NON, PRA461
MIL-H-5606G HYDRAULIC FLUID
IMPERIAL 2075TH (QUAL #634D346)
34-SX-97 PAINT STRIPPER, 4479
TAP WIZARD CUTTING/TAPPING FLUID, 3859
599 INSTRUMENT LUBRICANT 1 GALLON
599 INSTRUMENT LUBRICANT 5 GALLON
FLUID FILM GEL WRO-EP
599 INSTRUMENT LUBRICANT 15 GALLON
599 INSTRUMENT LUBRICANT 30 GALLON
TASK MASTER BULK, TM1G
STEEL SHOT AND GRIT 7439-89-6
7439-96-5
7440-21-3
7440-44-0
7704-34-9
7723-14-0
7440-50-8
7440-47-3
7440-02-0
INTERSHIELD PRORECO 58, PRA050 110-43-0
101-68-8
27083-55-2
26447-40-5
9016-87-9
ICE MELT/ANTIFREEZE 57-55-6
PLASTIC, PP 13S10A 9010-79-1
MTS SOLUTION, G109
RTV 5140 SILICONE POTTING COMPOUND, 18120 70131-67-8
67762-90-7
1185-55-3
67-56-1
KLEAN N PRIMER, 30566 67-64-1
75-28-5
149-57-5
22221-10-9
58823-74-8
7439-92-1
7440-02-0
477 FIRE RETARDANT EPOXY COMPONENT B
POTASSIUM CHLORIDE, 0865
AROMATIC 150 FLUID
METALCLAD CERAMALLOY CL+[AC] ACTIVATOR
CAP-STUN WEAPON SYSTEMS
OVERKOTE E-100 VERTIC 212295
OVERKOTE E-100 VERTIC 212101, 122201160
E7018, E7018AC
POTASSIUM CHLORIDE, 3619
SODIUM CHLORIDE 7647-14-5
02816,LPS HIGH PURITY NOFLASH CLEANER 1717-00-6
67-63-0
124-38-9
POLYVINYL CHLORIDE 9002-86-2
117-81-7
75-01-4
N-6605 LSA HAZE GRAY ENAMEL
COLOR GUARD TOUGH RUBBER COATING BLACK, 81812 64742-48-9
66070-58-4
110-54-3
108-88-3
78-93-3
HIGH SOLIDS MAX COR PRIMER, R4001 1330-20-7
64742-95-6
123-42-2
78-93-3
108-83-8
14807-96-6
7789-06-2
INTERSHIELD PRORECO, PRA150 25068-38-6
110-43-0
64539-51-1
25036-25-3
68609-97-2
9072-62-2
1309-37-1
INTERSHIELD PRORECO 159, PRA151
ULANOGEL 23 7732-18-5
409-21-2
102-71-6
PROPANE
INTERSHIELD PRORECO 508, PRA560 110-43-0
55636-48-1
59330-00-6
USCO/WH: 113R79, 5614, 5113/5114, COPY CARTRIDGE, (SUPDAT)
RUST AWAY 7664-38-2
7647-01-0
AROCLOR 1221 SOLUTION, PP-292 540-84-1
11104-28-2
HIT HY 150, PART A
HIT HY 150, PART B 14808-60-7
7732-18-5
94-36-0
25265-71-8
7631-86-9
9002-88-4
POTASSIUM CHLORIDE, 6788
POTASSIUM CHLORIDE, 6801
960 ACRYLIC COVE BASE ADHESIVE
ODC-FREE CLEANER & DEGREASER, 22355 64742-48-9
5989-27-5
124-38-9
FORMICA 100 SUPER +, F100
POLYSPEC LUX 31
ECA 2PA

Free MSDS Search ( Providing 250,000+ Material Properties )