LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:ANESTHETIC. RESPIRATORY
IRRITATION, DIZZINESS, HEADACHE, UNCONSCIOUSNESS. SKIN/EYE:PRIMARY
IRRITATION. CHRONIC:EFFECTS OF EXCESSIVE CHRONIC EXPOSURE TO
PRODUCT HAVE NOT BEEN FULLY INVESTIG ATED. REPEATED HANDLING OR USE
MAY PRESENT ADDITIONAL HAZARDS. EXERCISE DUE CARE.
Explanation of Carcinogenicity:NONE SPECIFIED BY MANUFACTURER.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL:REMOVE FROM EXPOSURE. UNCON, BUT BREATHING, GIVE O*2.
NOT BREATHING, ARTF RESUSCITATION. EYE:FLUSH W/COPIOUS AMTS OF
WATER FOR AT LEAST 15 MIN. SEE MD. SKIN:WASH THOROUGHLY W/SOAP &
WATER. USE H AND LOTION. INGEST:CALL MD IMMEDIATELY .
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:22.0F,-5.6C
Extinguishing Media:CARBON DIOXIDE OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:EXPLOSION HAZARD DUE TO PRESSURE BUILD-UP
DUE TO HEAT.
Spill Release Procedures:PROVIDE ADEQUATE VENTILATION. AVOID EXCESSIVE
HEAT, SPARKS AND OPEN FLAME. CLEAN UP W/RAGS. PLACE DIRTY RAGS IN
CONTAINER OF WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COOL, WELL VENT AREA. AVOID
EXCESSIVE HEAT, SPARKS & OPEN FLAMES. GROUND CNTNRS & TRANSFER
VESSELS. KEEP FREE FALL OF LIQUID (SEE SUPP DATA)
Other Precautions:DO NOT TAKE INTERNALLY. AVOID PROLONGED BREATHING OF
VAPORS. AVOID PROLONGED CONTACT WITH SKIN.
Respiratory Protection:IN CONFINED AREAS USE:NIOSH/MSHA APPROVED AIR
LINE TYPE RESPIRATORS OR HOODS.
Ventilation:MECH/GEN EXHST:SOLVENT VAPORS SHOULD BE REMOVED BY DILUTION
VENT FROM LOWER LEVELS. LOCAL EXHST:KEEP (SEE SUPP DATA)
Protective Gloves:PROTECTIVE GLOVES RECOMMENDED.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:AS REQUIRED TO AVOID SKIN CONTACT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HNDLG/STOR PREC:TO A FEW INCHES TO AVOID BUILD-UP OF STATIC
ELECTRICITY. VENT:VAPORS BELOW LEL AND TLV. ELIMINATE ALL IGNITION
SOURCES.
HCC:F3
Boiling Pt:B.P. Text:165F,74C
Vapor Density:HVR/AIR
Spec Gravity:1.03
Appearance and Odor:PINK
Percent Volatiles by Volume:67.5
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:EXCESSIVE HEAT, SPARKS, OPEN FLAMES.
Hazardous Decomposition Products:CARBON MONOXIDE MAY BE FORMED BY
INCOMPLETE COMBUSTION.
Conditions to Avoid Polymerization:EXCESSIVE HEAT, SPARKS AND OPEN
FLAMES.
Waste Disposal Methods:DISTILL OFF SOLVENTS UNDER STRICTLY SAFE
CONDITIONS. RE-USE DISTILLATE. DISPOSE OF RESIDUE AS LANDFILL.
DISPOSE OF I/A/W FEDERAL, STATE AND LOCAL REGULALTIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.