===================== Product Identification =====================
MSDS NAME:TEFLON PRIMERS, 850-300
NIIN:00N015194
MSDS Number: BKNPS
=== Responsible Party ===
Company:E I DUPONT DE NEMOURS & CO
Address:FINISHES & FABRICATED PRODUCTS DEPT
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Info Phone Num:800-441-7515
Emergency Phone Num:800-441-3637;800-424-9300(CHEMTREC)
CAGE:0ERJ7
=== Contractor Identification ===
Company:E I DUPONT DE NEMOURS & CO, INC.
Address:1007 MARKET STREET
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-441-7515
CAGE:0ERJ7
Company:E.I. DUPONT DE NEMOURS & CO
Address:1007 MARKET STREET
Box:City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-441-7515;800-441-9442
CAGE:18873
============= Composition/Information on Ingredients =============
Name:ING 4: INCREASES. HYDROGEN FLUORIDE IS TOX & CAN CAUSE SKIN
& EYE IRRIT (3PPM-ACGIH). HIGH CONC CAN CAUSE (SEE ING 6)
RTECS #:9999999ZZ
Name:ING 5: LUNG DMG, PULM EDEMA/BURNS. SOME VEGETATION IS
PARTICULARLY SENSITIVE TO DMG BY HF & ATTN MUST BE (SEE ING 7)
RTECS #:9999999ZZ
Name:ING 6: GIVEN TO EXHAUST LOCATIONS. OXIDES OF HEAVY METALS
REPORTED IN INGREDIENT SECTION, IF ANY.
RTECS #:9999999ZZ
Name:FLUOROPOLYMER SOLIDS
Name:SULFURIC ACID, MONODODECYL ESTER, SODIUM SALT
CAS:151-21-3
RTECS #:WT1050000
Name:SUPP DATA: BRTHG VAPS EMITTED DURING BAKING. DO NOT EXCEED
REC BAKING TEMPS. BAKING OVENS MUST BE PROPERLY (SEE ING 4)
RTECS #:9999999ZZ
Name:ING 3: VENT. AT TEMPS >400C (750F) SM AMTS OF HYDROGEN
FLUORIDE CAN BE EVOLVED; AMTS INCREASE AS TEMP (SEE ING 5)
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: OVEREXP TO VAPS DURING SPRAY
APPLICATN MAY CAUSE NOSE & THROAT IRRIT. MAY CAUSE NERV SYS DEPRESS
CHARACTERIZED BY THE FOLLOWING PROGRESSIVE STEPS: HDCH, DIZZ, NAUS,
STAG GAIT, CONFUSN, UNCONS. RPTS HAVE ASSOC RPTD & PRLNGD OVEREXP
TO SOLV W/PERM BRAIN DMG & NERV SYS DMG. SKIN/EYE: MAY (SEE EFTS OF
OVEREXPOSURE)
Explanation of Carcinogenicity:NONE SPECIFIED BY MANUFACTURER.
Effects of Overexposure:HLTH HAZ: CAUSE IRRIT/BURNING OF EYES.
RPTD/PRLNGD LIQ CONT MAY CAUSE SKIN IRRIT W/DISCOMFORT & DERM.
OTHER POTENTIAL HAZ INCLUDE: ING 1: SEE HAZ DECOMP PRODS. ING 2:
OVEREXP MAY CAUSE EYE, NOSE AND T HROAT IRRIT. RPTD/PRLNGD CONT MAY
CAUSESKIN IRRIT W/DISCOMFORT & DERMAT. CAUSES SEVERE EYE IRRIT.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL: REMOVE TO FRESH AIR. IF NOT BRTHG, GIVE ARTF RESP,
PREF MOUTH-TO-MOUTH. IF BRTHG DIFFICULTY PERSISTS/OCCURS LATER,
CONSULT MD. SKIN/EYE: IMMED FLUSH W/PLENTY OF WATER FOR AT LEAST 15
MIN; CALL MD. IN CASE OF SKIN CONT, WASH W/SOAP &WATER. IF IRRIT
OCCURS, CALL MD. INGEST: GI DISTRESS. IN UNLIKELY EVENT OF INGEST,
CALL MD IMMED & HAVE NAMES OF INGRED AVAIL.
===================== Fire Fighting Measures =====================
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
WATER FROM FOG NOZZLES MAY BE USED TO COOL CLSD CNTNRS TO PVNT
PRESS BUILD-UP.
Unusual Fire/Explosion Hazard:WHEN HEATED ABOVE FLASH PT, EMITS FLAM
VAPS WHICH, WHEN MIXED W/AIR, CAN BURN/BE EXPLOS. FINE MISTS/SPRAYS
MAY BE FLAM AT TEMPS BELOW FLASH PT. (SEE SUPP DATA)
================== Accidental Release Measures ==================
Spill Release Procedures:VENT AREA. REMOVE SOURCES OF IGNITION. AVOID
SKIN CONTACT AND BREATHING OF VAPOR. CONFINE AND REMOVE WITH INERT
ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:OBSERVE LABEL PREC. KEEP AWAY FROM
HEAT, SPARKS & FLAME. CLOSE CNTNR AFTER EACH USE. GROUND CNTNRS
WHEN POURING. DO NOT STORE ABOVE 120F. (OTHER PREC)
Other Precautions:HNGLD/STOR PREC: EXPLO RXN MAY OCCUR ABOVE 796F
W/FINELY DIVIDED FLUOROCARBON & METAL POWDER (ALUMINUM/MAGNESIUM).
OPERATIONS SUCH AS GRINDING, BUFFING/GRIT BLASTING MAY GENERATE
SUCH MIXTURES. KEEP W ET. USE ADEQUATE VENT TO CONTROL.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:DO NOT BREATHE VAPS/MISTS. WEAR A PROPERLY
FITTED NIOSH/MSHA APPRVD VAPOR/PARTICULATE RESP FOR USE W/PAINTS
DURING APPLICATN & UNTIL ALL VAPS & SPRAY MIST ARE EXHAUSTED.
FOLLOW RESP MFR DIRECTIONS FOR RESPIRATOR USE.
Ventilation:PROVIDE SUFFICIENT VENT IN VOLUME & PATTERN TO KEEP
CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:COVERALLS.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING AND SMOKING.
Supplemental Safety and Health
% VOLAT: 46.2-47.3(WT). EXPLO HAZ: HYDROGEN FLUORIDE IS RELEASED DURING
A FIRE. HAZ DECOMP: SYMP DO NOT ORDINARILY OCCUR UNTIL SEV HRS
AFTER EXPOS & PASS WITHIN 36-48 HRS. EFTS ARE NOT CUMULATIVE. EXP
OS USUALLY RESULTS FROM SMOKING TOBACCO/CIGARETTES CONTAMINATED
W/THE FLUOROCARBON DURING HANDLING/FROM (SEE ING 3)
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:172F,78C
Vapor Pres:NONE
Vapor Density:>AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:SLIGHT
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:SUPDAT
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:EXPOS TO TEFLON DECOMP PRODS CAN
CREATE INFLUENZE-LIKE SYM, COMMONLY REFERRED TO AS POLYMER FUME
FEVER. THESE (SUP DATA)
==================== Disposal Considerations ====================
Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
WATER SYSTEMS. INCINERATE ABSORBED MATERIAL IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REQUIREMENTS. DO NOT INCINERATE IN CLOSED
CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|