LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EYE: IRRITATING. SKIN: MAY CAUSE
IRRIT. INHAL: CAUSES IRRITATION. MAY CAUSE ALLERGIC TYPE RESPONSE.
INGEST: ACUTE TOXICITY ESTIMATED TO BE LOW.
Explanation of Carcinogenicity:TOLUENE DIISOCYANATE:IARC - 2B, NTP - 2.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYE: FLUSH EYES WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES
AND CALL MD. SKIN: WASH WITH SOAP AND WATER. INHAL: PROVIDE
UNCONTAMINATED AIR. CONTACT MD IN CASE OF BREATHING DIFFICULTY.
INGEST: INDUCE VOMITNG. CALL MD.
===================== Fire Fighting Measures =====================
Flash Point Method:SCC
Flash Point:16.0F,-8.9C
Lower Limits:2.6
Upper Limits:12.8
Extinguishing Media:CO*2, FOAM, DRY CHEMICAL OR WATER.
Fire Fighting Procedures:FIREFIGHTERS SHOULD BE EQUIPPED WITH A
NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT WHEN
FIGHTING FIRES INVOLVING THIS MATERIAL.
Unusual Fire/Explosion Hazard:EXTREMELY FLAMMABLE. OVERHEATED, CLOSED
CONTAINERS ADJACENT TO FIRE COULD EXPLODE DUE TO PRESSURE BUILDUP.
Spill Release Procedures:OBSERVE PREC INFO. PVNT MATL FROM ENTERING
DRAINS; USE DIKING/COVER FLOOR DRAINS IF NEC. IF MATL ENTERS DRAIN,
FLUSH W/LG AMTS WATER. COVER SPILL W/AN ABSORBENT MATL. COLLECT IN
OPENHEAD DRUM/PAIL, ST IR IN AN EST EQUAL AMT WATER & LET SIT 1/2
HR.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP PROD & ITS VAPS AWAY FROM HEAT,
SPARKS, OPEN FLAMES. DO NOT BREATHE VAPS. USE ONLY IN AREAS ADEQ
VENTED W/ENOUGH AIR MOVEMENT TO (SEE OTHER PREC)
Other Precautions:HNDLG/STOR PREC: REMOVE VAPS & PVNT ATM CONC OF
ISOCYANATES FROM EXCEEDING CURRENT TLVS. UNTIL SUCH VENT CAN BE
MADE AVAIL WEAR A NIOSH/MSHA APPRVD RESP RATED FOR ISOCYANATE VAPS.
AVOID CTCT W/EYES & SKIN. KEEP CNTNR CLOSED WHEN NOT IN USE.
Respiratory Protection:WEAR A NIOSH/MSHA APPROVED RESPIRATOR RATED FOR
ISOCYANATE VAPOR IF VENTILATION IS NOT ADEQUATE.
Ventilation:LOCAL EXHAUST.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:APRON RECOMMENDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
WASTE DISP METH: STATE AND FEDERAL REGULATIONS . UNCURED LIQ WASTE MATL
IS DESIGNED AS DOO1 (FLAMMABLE WASTE) BY USEP RCRA STD. (40 CFR
PART 261.21).
HCC:F2
Boiling Pt:B.P. Text:134F,57C
Vapor Pres:180 @ 68F
Vapor Density:2.0
Spec Gravity:1.10
Evaporation Rate & Reference:1.9 (ETHER=1)
Solubility in Water:REACTS WITH WATER
Appearance and Odor:AMBER LIQUID WITH ACETONE ODOR.
Percent Volatiles by Volume:15
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
MOISTURE, WATER.
Stability Condition to Avoid:MOISTURE.
Hazardous Decomposition Products:CO, CO*2, NO*X AND SMOKE PARTICLES
WHEN SUBJECTED TO EXCESSIVE HEAT OR FLAME.
Conditions to Avoid Polymerization:REACTS WITH WATER TO FORM FOAM.
Waste Disposal Methods:IF WASTE IS FULLY CURED (BY MIXING W/SUFFICIENT
WATER), THE GEL COULD BE BURIED IN A SANITARY LANDFILL. UNCURED LIQ
WASTE SHOULD BE DISP OF BY CHEM INCIN/AT A DISP FAC CAPABLE OF
HNDLG FLAMM WASTES. W ASTES SHOULD BE DISP I/A/W LOCAL, (SEE SUPP
DATA)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.