LD50 LC50 Mixture:LD50:ORAL(RAT)=>24000 MG/KG
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: NONE SPECIFIED BY MANUFACTURER.
CHRONIC: NONE KNOWN.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL: REMOVE TO FRESH AIR. EYE: BEGIN IMMED EYE IRRIGATION
WITH COOL WATER. SKIN: WASH CONTAMD AREA(S) WITH SOAP AND WATER.
INGEST: GIVE A MINIMUM OF TWO GLASSES OF WATER.
===================== Fire Fighting Measures =====================
Extinguishing Media:DRY CHEMICAL, WATER SPRAY (FOG), FOAM OR CARBON
DIOXIDE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:CMPD CONTAINING PHENOLIC GROUPS ARE KNOWN
TO HAVE A SEVERE DUST EXPLOSIVITY RATING. REFER TO "OTHER
PRECAUTIONS" FOR SAFETY MEASURES.
Spill Release Procedures:SWEEP OR SHOVEL INTO APPROPRIATE CONTAINER FOR
DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:EMPLOY BONDING, GROUNDING, VENTING & EXPLOSION RELIEF
PROVISIONS IN ACCORD WITH ACCEPTED ENGINEERING PRACTICES IN PROCESS
OPERATIONS CAPABLE OF GENERATING DUST/STATIC ELECTRICITY. EXPLOS
HAZ CAN BE RE DUCED BY GOOD HOUSEKEEPING, PVNT(SUPDAT)
Respiratory Protection:NIOSH/MSHA APPROVED NUISANCE DUST RESPIRATOR, AS
NEEDED.
Ventilation:LOCAL: TO CONTROL DUSTING. MECHANICAL: RECOMMENDED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLOS HAZ: OF THE ESCAPE OF DUST FROM PROCESS EQUIP, & PVNT ACCUM OF
DUST ON OVERHEAD, HORIZONTAL SURF. IN ADDN, A CONTINUING EFFORT
SHOULD BE MADE TO CONTROL IGNIT SOURCES.
HCC:N1
Boiling Pt:B.P. Text:250C/482F
Melt/Freeze Pt:M.P/F.P Text:154C/482F
Solubility in Water:NEGLIGIBLE.
Appearance and Odor:LIGHT STRAW COLORED, CRYSTALLINE POWDER/NO ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:EXTREMELY HIGH TEMPERATURES.
Hazardous Decomposition Products:INCLUDE OXIDES OF CARBON.
Waste Disposal Methods:UNDER CERCLA/RCRA RES IN EFT DEC 29, 1986, THIS
PROD IS NOT REGULATED AS A HAZ WASTE/MATL. THEREFORE, IT MAY BE
DISPOSED OF AS AN INDUSTRIAL WASTE IN A MANNER ACCEPTABLE TO GOOD
WASTE MANAGEMENT PRACT ICE & I/A/W APPLIC LOCAL, STATE, & FEDERAL
REGS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.