LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN:DRYING. EYE:IRRITATION.
INHAL:EXCESSIVE EXPOSURE MAY CAUSE ANESTHESIA, HEADACHE, DIZZINESS,
NAUSEA, & UPPER RESPIRATORY IRRITATION.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL:REMOVE TO FRESH AIR, APPLY ARTIFICIAL RESPIRATION IF
NECESSARY. CALL MD. SKIN:WASH W/MILD SOAP & WATER, APPLY A MILD
SKIN CREAM. IN SEVERE CASES, CALL MD. EYE:FLUSH W/WATER FOR AT
LEAST 15 MINUT ES. CALL MD. INGEST:CALL MD.
===================== Fire Fighting Measures =====================
Flash Point Method:SCC
Flash Point:45.0F,7.2C
Lower Limits:1%
Upper Limits:7%
Extinguishing Media:FOAM, CARBON DIOXIDE OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:VAPORS MAY FORM EXPLOSIVE MIXTURES W/AIR.
Spill Release Procedures:WASH W/WATER INTO RETAINING AREA OR CONTAINER.
AVOID SPARKS, FIRE OR HOT METAL SURFACES. SMALL QUANTITIES MAY BE
ABSORBED ONTO AN APPROPRAITE ABSORBANT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP COOL & AWAY FROM SOURCES OF
IGNITION. USE W/ADEQUATE VENTILATION. AVOID PROLONGED OR REPEATED
PERSONAL CONTACT.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Respiratory Protection:ABOVE TLV USE NIOSH/MSHA CARTRIDGE RESPIRATOR OR
GAS MASK.
Ventilation:LOCAL EXHAUST:USE WHATEVER IS SUFFICIENT TO KEEP WORKROOM
CONCENTRATION BELOW TLV.
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:APRON & BARRIER CREAM.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods:INCINERATE UNDER SAFE CONDITIONS OR DISPOSE OF
ACCORDING TO APPLICABLE LOCAL, STATE & FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.