===================== Product Identification =====================
MSDS NAME:ARGON
NIIN:00N070350
MSDS Number: CBLQM
=== Responsible Party ===
Company:AMEREX CORP
Box:81
City:TRUSSVILLE
State:AL
ZIP:35173-0081
Country:US
Info Phone Num:205-655-3271
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:DO025
=== Contractor Identification ===
Company:AMEREX CORP
Box:81
City:TRUSSVILLE
Phone:205-655-3271/800-424-9300(CHEMTREC)
CAGE:DO025
Company:AMEREX CORPORATION
Address:7595 GADSDEN HWY E
Box:81
City:TRUSSVILLE
State:AL
ZIP:35173-0081
Country:US
Phone:205-655-3271
CAGE:54905
============= Composition/Information on Ingredients =============
Name:ARGON
CAS:7440-37-1
RTECS #:CF2300000
Fraction by Wt: 100%
OSHA PEL:N/K
ACGIH TLV:ASPHYXIANT
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: SIMPLE ASPHY WHICH
EXERTS NO OTHER PHYSIOLOGICAL EFT BEYOND OXYGEN DEPRIVATION. SYMPS
OF OVEREXP INCL DIZZ, HDCH, LOSS OF CONSCIOUSNESS & DEATH.
SKIN/EYES: CONT W/RAPIDLY EXPANDING GASES MAY CAUSE
BURNS/FROSTBITE. CHRONIC: ARGON IS NOT KNOWN TO CAUSE ANY CHRONIC
ILLNESSES OR DISEASES.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL: REMOVE TO FRESH AIR AS QUICKLY AS POSS. TRAINED PERS
SHOULD ADMIN SUPPLEMENTAL OXYGEN &/CARDIO-PULM RESUSCITATION, IF
NEC. ONLY TRAINED PERS SHOULD ADMIN SUPPLEMENTAL OXYGEN. SKIN: IN
CASE OF F ROSTBITE, PLACE FROSTBITTEN PART IN WARM WATER. IF WARM
WATER IS NOT AVAIL/IMPRACTICAL TO USE, WRAP AFFECTED PARTS GENTLY
IN BLANKETS. EYES: FLUSH W/POTABLE WATER FOR AT LEAST 15 MIN. SEE
MD . I NGEST: CALL MD IMMED . IF EXPOS CAUSES OBVIOUS DISTRESS,
VICTIMS & RESCUERS MUST BE TAKEN FOR MED ATTN. TAKE COPY OF LABEL &
MSDS TO MD/HLTH PROFESSIONAL W/VICTIM.
===================== Fire Fighting Measures =====================
Extinguishing Media:NOT NORNALLY IGNITABLE. USE WATER SPRAY, DRY
CHEMICAL, CARBON DIOXIDE, HALON, FOAM, ANY "B" CLASS.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . KEEP UNUSED CYLINDERS COOL USING A WATER
SPRAY.
Unusual Fire/Explosion Hazard:WHEN INVOLVED IN A FIRE, THIS CYLINDER
UNDER MAY RUPTURE VIOLENTLY, CAUSING A HIGH PRESSURE RELEASE OF
GASES.
================== Accidental Release Measures ==================
Spill Release Procedures:UNCONTROLLED RELEASES SHOULD BE RESPONDED TO
BY TRAINED PERS USING PRE-PLANNED PROC. PROPER PROT EQUIP SHOULD BE
USED. IN CASE OF RELEASE, CLEAR AFFECTED AREA, PROTECT PEOPLE, &
RESPOND W/TRAINED PERS . FOR UNCONTROLLED RELEASES, MONITOR THE
SURROUNDING AREA FOR OXYGEN CONTENT. ATM MUST HAVE AT LEAST 19.5%
OXYGEN BEFORE PERS CAN BE ALLOWED AREA W/OUT SCBA. CARE SHOULD BE
TAKEN TO AVOID (SUP DAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:ALL EMPLOYEES WHO HANDLE THIS MATL
SHOULD BE TRAINED TO HANDLE IT SAFELY. KEEP CYL IN DRY, WELL-VENT
AREAS WHICH ARE AWAY FROM SOURCES OF HEAT.
Other Precautions:DO NOT EXCEED 48C STOR TEMP. KEEP CYL SECURE. BEFORE
USE: MOVE CYL W/SUITABLE HAND-TRUCK. SECURE CYL FIRMLY. LEAVE VALVE
PROT CAP IN PLACE UNTIL CYL IS READY FOR USE. DURING USE: USE
DESIGNATED REGULA TORS, CGA FITTINGS, & OTHER SUPPORT EQUIP. DO NOT
USE ADAPTERS. DO NOT USE OIL/GREASE ON GAS HNDLG F ITTINGS/ (SUP
DAT)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE NORMALLY REQUIRED FOR USE. USE NIOSH/MSHA
APPROVED AIR RESPIRATORY PROTECTION IF OXYGEN LEVELS ARE BELOW
19.5%.
Ventilation:USE WITH ADEQUATE VENTILATION. USE A MECHANICAL FAN, OR
VENT AREA TO OUTSIDE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA . USE BODY PROTECTION APPROPRIATE FOR TASK.
Work Hygienic Practices:AVOID GETTING CHEM ON YOU/IN YOU. WASH HANDS
AFTER HANDLING CHEMICALS. DO NOT EAT OR DRINK WHILE HANDLING
CHEMICALS.
Supplemental Safety and Health
SPILL PROC: CONT W/RAPIDLY EXPANDING GASES. VENTILATE AFFECTED AREA.
OTHER PREC: EQUIP. ALL EQUIP MUST BE PROPERLY GROUNDED & BONDED.
AFTER USE: CLOSE MAIN CYL VALVE. REPLACE VALVE PROT CAP. MARK EMPT
Y CYL "EMPTY". FOLLOW PRACT INDICATED IN "ACCIDENTAL RELEASE
MEASURES". MAKE CERTAIN APPLICATION EQUIP IS (OTHER INFO)
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:-303F,-186C
Melt/Freeze Pt:M.P/F.P Text:-309F,-189C
Spec Gravity:1.38 (AIR=1)
Solubility in Water:0.033 CM/CM3 WATER
Appearance and Odor:ODORLESS, COMPRESSED GAS
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ARGON IS NON-CORR & INERT, & MAY BE CONTAINED IN SYS CONSTRUCTED OF ANY
COMMON METALS & DESIGNED TO SAFELY WITHSTAND PRESSURES INVOLVED.
Stability Condition to Avoid:ELEVATED TEMPERATURES.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
==================== Disposal Considerations ====================
Waste Disposal Methods:WASTE DISPOSAL MUST BE IN ACCORDANCE WITH
APPROPRIATE FEDERAL, STATE AND LOCAL REGULATIONS. DO NOT PUNCTURE
OR INCINERATE CYLINDER.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|