===================== Product Identification =====================
MSDS NAME:01976 RUST PROOF COMPOUND L
NIIN:00N070348
MSDS Number: CBLQK
=== Responsible Party ===
Company:TEXACO
Box:4427
City:HOUSTON
State:TX
ZIP:77210-4427
Country:US
Info Phone Num:914-838-7204;914-831-3400
Emergency Phone Num:914-831-3400;800-424-9300(CHEMTREC)
CAGE:06668
=== Contractor Identification ===
Company:TEXACO PIPELINE INC (SUB OF TEXACO INC)
Address:9700 RICHMOND AVE
Box:42286
City:HOUSTON
State:TX
ZIP:77242-2286
Country:US
Phone:713-953-4260
CAGE:3B431
Company:TEXAS INSTRUMENTS INC INFORMATION TECHNOLOGY GROUP
Address:14902 SOMMERMEYER ST NO 100
Box:1444
City:HOUSTON
State:TX
ZIP:77251
Country:US
Phone:800-336-5236
CAGE:06668
============= Composition/Information on Ingredients =============
Name:PETROLATUM; (COMPLEX MIXTURE OF PETROLEUM HYDROCARBONS) %
(WT): 35.00-49.99
CAS:8009-03-8
RTECS #:SE6780000
Fraction by Wt: SEE ING
OSHA PEL:N/K
ACGIH TLV:N/K
Name:SOLVENT DEASPHALTED RESIDUAL PETROLEUM OIL; (SEVERELY
HYDROTREATED HEAVY NAPHTHENIC DISTILLATE) % (WT): 20.00-34.99
CAS:64741-95-3
Fraction by Wt: SEE ING
OSHA PEL:N/K
ACGIH TLV:N/K
Name:STODDARD SOLVENT; (PETROLEUM WASTE HYDROCARBONS (C8 OR
GREATER) % (WT): 20.00-34.99
CAS:8052-41-3
RTECS #:WJ8925000
Fraction by Wt: SEE ING
OSHA PEL:500 PPM
ACGIH TLV:100 PPM
Name:GREASE; (WOOL GREASE)
CAS:8020-84-6
Fraction by Wt: 3-9.99%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:STEARIC ACID, BUTYL ESTER; (STEARIC ACID, ALKYL ESTER)
CAS:123-95-5
RTECS #:NI2900000
Fraction by Wt: 1-2.99%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:FIRST AID PROC: RESP IRRIT PERSISTS. OTHER INSTRUCTIONS:
HIGH PRESS INJECTION OF MATL CAN CAUSE SEV INJURY. (ING 7)
RTECS #:9999999ZZ
Name:ING 6: FAILURE TO DEBRIDE WOUND OF ALL RESIDUAL MATL CAN
RSLT IN DISFIGUREMENT, LOSS OF FUNCTION/MAY REQUIRE (ING 8)
RTECS #:9999999ZZ
Name:ING 7: AMPUTATION OF AFFECTED AREA. REMOVE &
DRY-CLEAN/LAUNDER CONTAM CLTHG SOAKED/SOILED W/THIS MATL BEFORE
(ING 9)
RTECS #:9999999ZZ
Name:ING 8: REUSE. DRY CLEANING OF CONTAM CLTHG MAY BE MORE
EFFECTIVE THAN NORM LAUNDERING. INFORM INDIVIDUALS (ING 10)
RTECS #:9999999ZZ
Name:ING 9: RESPONSIBLE FOR CLEANING OF POTENTIAL HAZARDS
ASSOCIATED WITH HANDLING CONTAMINATED CLOTHING.
RTECS #:9999999ZZ
Name:WASTE DISP METH: RCRA CRITERIA FOR HAZ WASTE. THIS IS
BECAUSE PROD USES, TRANSFORMATIONS, MIX, PROCESSES, ETC, (ING 12)
RTECS #:9999999ZZ
Name:ING 11: CHANGE CLASSIFICATION TO NON-HAZARDOUS/HAZARDOUS
FOR REASONS OTHER THAN OR IN ADDITION TO IGNITABILITY. (ING 13)
RTECS #:9999999ZZ
Name:ING 12: DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE, AND
FEDERAL REGULATIONS .
RTECS #:9999999ZZ
Name:OTHER PREC: MISUSE OF EMPTY CONTRS CAN BE HAZ. EMPTY CONTRS
CAN BE HAZ IF USED TO STORE TOX, FLAMM/REACTIVE (ING 15)
RTECS #:9999999ZZ
Name:ING 14: MATERIALS. CUTTING/WELDING OF EMPTY CONTAINERS
MIGHT CAUSE FIRE, EXPLOSION/TOX FUMES FROM RESIDUES. (ING 16)
RTECS #:9999999ZZ
Name:ING 15: DO NOT PRESSURIZE OR EXPOSE TO OPEN FLAME OR HEAT.
KEEP CONTAINER CLOSED AND DRUM BUNGS IN PLACE.
RTECS #:9999999ZZ
Name:RESP PROT: AIRBORNE CONC OF CONTAMINANT. NIOSH/MSHA APPRVD
AIR-SUPPLIED RESP SHOULD ALWAYS BE WORN WHEN (ING 18)
RTECS #:9999999ZZ
Name:ING 19: AIRBORNE CONCENTRATION OF THE CONTAMINANT OR OXYGEN
CONTENT IS UNKNOWN.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50 (ORAL RAT): > 5 G/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYES:MAY CAUSE MIN IRRIT,
EXPERIENCED AS TEMPORARY DISCOMFORT. SKIN:PRLNG CONT, AS W/CLTHG
WETTED W/MATL, MAY CAUSE DEFAT/IRRIT, SEEN AS LOC REDNESS W/POSS
MILD DISCOMFORT. INHAL:VAPS/MIST, IN E XCESS OF PERMISSIBLE
CONCS/IN UNUSUALLYHIGH CONCS GENERATED FROM SPRAYING, HEATING
MATL/AS FROM EXPOS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:IN POORLY VENT AREAS/CONFINED SPACES,
MAY CAUSE IRRIT OF NOSE & THROAT, HDCH, NAUS & DROW. INGEST:IF MORE
THAN SEVERAL MOUTHFULS ARE SWALLOWED, ABDOM DISCOMFORT, NAUS &
DIARR MAY OCCUR. CHRON IC:NO ADVERSE EFTS HAVE BEEN DOCUMENTEDIN
HUMANS AS RSLT OF CHRONIC EXPOS. OTHER REMARKS:MATL FROM HIGH PRESS
(SUP DAT)
Medical Cond Aggravated by Exposure:BECAUSE OF ITS DEFATTING
PROPERTIES, PROLONGED AND REPEATED SKIN CONTACT MAY AGGRAVATE AN
EXISTING DERMATITIS (SKIN CONDITION).
======================= First Aid Measures =======================
Eyes: FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MIN. GET MED
ATTN IF IRRIT PERSISTS. SKIN: WASH W/PLENTY OF SOAP & WATER FOR
SEVERAL MIN. GET MED ATTN IF IRRIT DEVELOPS/PERSISTS. INGEST: IF
MORE THAN SE VERAL MOUTHFULS OF THIS MATL ARE SWALLOWED, GIVE 2
GLASSES OF WATER (16 OZ). GET MED ATTN. INHAL: IF IRRIT, HDCH,
NAUS/DROW OCCUR, REMOVE TO FRESH AIR. GET MED ATTN IF BRTHG BECOMES
DFCLT OR (ING 6)
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:125F,52C
Extinguishing Media:USE WATER SPRAY, DRY CHEM, FOAM/CARBON DIOXIDE TO
EXTING FLAMES. USE WATER SPRAY TO COOL FIRE-EXPOSED CONTAINERS.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE AREA. AVOID BREATHING VAP. WEAR
APPROPRIATE PERS PROT EQUIP, INCLUDING APPROP RESP PROT. CONTAIN
SPILL IF POSS. WIPE UP/ABSORB ON SUITABLE MATL & SHOVEL UP. PREVENT
ENTRY INTO SEWERS & WATER WAYS. AVOID CONTACT W/SKIN,
EYES/CLOTHING.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:MINIMAL FEASIBLE HANDLING TEMPERATURES
SHOULD BE MAINTAINED. STORE AWAY FROM HEAT AND OPEN FLAME.
Other Precautions:A PLACARD IS REQUIRED ONLY WHEN MATL IS CONTAINED IN
PACKAGING/CONTAINER THAT EXCEEDS 110 GALLONS, OR IN TANK CAR/TANK
TRUCK. TRANSPORT, HANDLE, AND STORE IN ACCORDANCE WITH OSHA
REGULATION 1910.106 A ND APPLICABLE DOT REGULATIONS. (ING 14)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:AIRBORNE CONCS SHOULD BE KEPT TO LOWEST LEVELS
POSS. IF VAP, MIST/DUST IS GENERATED & OCCUP EXPOS LIM OF PROD/ANY
COMPONENT OF PROD, IS EXCEEDED, USE APPROP NIOSH/MSHA APPRVD AIR
PURIFYING/AIR SUPPLIE D RESP AFTER DETERMINING THE (ING 17)
Ventilation:ADEQUATE TO MEET COMPONENT OCCUPATIONAL EXPOSURE LIMITS.
Protective Gloves:NONE SPECIFIED BY MANUFACTURER.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WORKERS SHOULD WASH EXPOSED SKIN SEVERAL TIMES
DAILY W/SOAP & WATER. SOILED WORK CLTHG SHOULD BE
LAUNDERED/DRY-CLEANED.
Supplemental Safety and Health
EFTS OF OVEREXP: EQUIP, PINHOLE LEAKS/HIGH PRESS LINE FAILURE CAN
PENETRATE SKIN &, IF NOT PROPERLY TREATED, CAN CAUSE SEV INJURY,
INCL DISFIGUREMENT, LOSS OF FUNCTION/EVEN REQUIRE AMPUTATION OF
AFFEC TED AREA. TO PVNT SUCH SERIOUS INJURY, IMMED MED ATTN SHOULD
BE SOUGHT EVEN IF INJECTION INJURY APPEARS TO BE MINOR.
================== Physical/Chemical Properties ==================
Appearance and Odor:DARK BROWN LIQUID
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:TOXIC LEVELS OF CARBON MONOXIDE,
CARBON DIOXIDE, IRRITATING ALDEHYDES AND KETONES.
==================== Disposal Considerations ====================
Waste Disposal Methods:THIS PROD (AS PRESENTLY CONSTITUTED) HAS RCRA
CHARACT OF IGNITABILITY, &, IF DISCARDED IN ITS PRESENT FORM, WOULD
HAVE HAZ WASTE # LF D001. UNDER RCRA, IT IS RESPONSIBILITY OF USER
OF PROD TO DETERMIN E, AT TIME OF DISP, WHETHER PROD MEETS (ING 11)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|