===================== Product Identification =====================
MSDS NAME:SINGLE ELEMENT PLASMA STANDARD SOLUTION, PLPT3-3X
NIIN:00N025926
MSDS Number: CFNQM
=== Responsible Party ===
Company:SPEX CHEMICAL
Address:203 NORCROSS AVE
City:METUCHEN
State:NJ
ZIP:00840
Country:US
Info Phone Num:908-549-7144
Emergency Phone Num:908-549-7144;800-424-9300(CHEMTREC)
Preparer's Name:VANAJA SIVAKUMAR
CAGE:IO043
=== Contractor Identification ===
Company:SPEX CERTIPREP INC
Address:203 NORCROSS AVE
Box:City:METUCHEN
State:NJ
ZIP:08840
Country:US
Phone:732-549-7144
CAGE:07977
Company:SPEX CHEMICAL
Address:203 NORCROSS AVE
Box:City:METUCHEN
State:NJ
ZIP:08840
Country:US
Phone:908-549-7144
CAGE:IO043
============= Composition/Information on Ingredients =============
Name:HYDROGEN CHLORIDE; (HYDROCHLORIC ACID) (SARA 302/313)
(CERCLA) (CONTAINING ING 2)
CAS:7647-01-0
RTECS #:MW4025000
Fraction by Wt: 10%
OSHA PEL:5 PPM, C
ACGIH TLV:5 PPM, C
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:PLATINUM
CAS:7440-06-4
RTECS #:TP2160000
Fraction by Wt: 0.1-1%
OSHA PEL:0.002 MG/M3 (MFR)
ACGIH TLV:1 MG/M3
Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: 90%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:SUPDAT:IN CONT W/EYES, IT PRDCES SEV BURNS WHICH MAY RSLT
IN PRLNG/PERM VISUAL IMPAIRMENT, INCL TOTAL LOSS OF (ING 5)
RTECS #:9999999ZZ
Name:ING 4:VISION. ON SKIN, CONC LIQ/VAP WILL CAUSE REDNESS,
PAIN & SEV BURNS. RPTD/PRLNG EXPOS TO DILUTE SOLNS MAY (ING 6)
RTECS #:9999999ZZ
Name:ING 5:CAUSE DERM. EROSION OF TEETH MAY OCCUR W/PRLNG EXPOS
TO CONC HYDROCHLORIC ACID. INGEST OF LIQ CAUSES SEV (ING 7)
RTECS #:9999999ZZ
Name:ING 6:BURNS OF MUC MEMBS OF MOUTH, ESOPHAGUS & STOM,
CAUSING; PAIN, NAUS & VOMIT. INHAL OF CONC HYDROCHLORIC ACID(ING 8)
RTECS #:9999999ZZ
Name:ING 7:MAY BE FATAL CAUSING SPASM, SEV IRRIT OF UPPER RESP
TRACT, INFLAMM & EDEMA OF LARYNX & BRONCHI & CHEM (ING 9)
RTECS #:9999999ZZ
Name:ING 8:PNEUM. SYMPS INCL COUGH, BURNING OF THROAT, INFLAMM
OF NOSE & CHOKING SENSATION. IF INHALED DEEPLY PULM (ING 10)
RTECS #:9999999ZZ
Name:ING 9:EDEMA MAY OCCUR.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SYMPS & HLTH HAZS FOR DILUTE
HYDROCHLORIC ACID ARE EXPECTED TO BE LESS SEV THAN EXPOS TO CONC
HYDROCHLORIC ACID. HOWEVER, SINCE HYDROCHLORIC ACID IS IN SOLN AT
1% OR GREATER, HLTH HAZS FOR CONC HYDROC HLORIC ACID ARE GIVEN. SOL
PLATINUM SALTS IN FORM OF DUSTS & SPRAYS CAUSE ASTHMA, SKIN SENSIT
& EYE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:IRRIT. PLATINOSIS IS CHARACT BY
ASTHMA, ECZEMA & UTICARA/IT MAY BE ASYMPTOMATIC & CHARACT BY COUGH,
DYSP, ITCH, CONJ VASODILATION & RHINOPHARYNGITIS. SKIN CONT CAN
RSLT IN CONT DERM. CONC HYD ROCHLORIC ACID MAY BE FATAL IF
INHALED,INGESTED/ABSORBED THRU SKIN. HYDROCHLORIC ACID VAP/MIST IS
IRRIT OF (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
Eyes:FLUSH W/WATER FOR AT LEAST 15 MINUTES OCCAS LIFTING
UPPER & LOWER EYELIDS. SKIN:REMOVE CONTAMINATED CLOTHING, THEN
FLUSH W/WATER FOR AT LEAST 15 MINUTES. WASH CLOTHING THORO BEFORE
REUSE. INHAL:M OVE TO FRESH AIR. INGEST:DO NOT INDUCE VOMITING.
IMMEDIATELY GET MEDICAL HELP. SEND TO HOSPITAL. ONLY IF PATIENT IS
CONSCIOUS, GIVE LARGE QTYS OF WATER/MILK. IF IRRIT CONTINUES, GET
MED ATTN IMMED.
===================== Fire Fighting Measures =====================
Extinguishing Media:APPROPRIATE TO SURROUNDING FIRE CONDITIONS.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT COMBUSTIBLE.
================== Accidental Release Measures ==================
Spill Release Procedures:VENT AREA. DILUTE SPILL W/WATER & NEUT W/SODA
ASH, LIMESTONE, ETC. WIPE UP & PUT INTO SEALED CNTNR FOR PROPER
DISP. WASH SPILL SITE OFF W/WATER AFTER MATL PICK-UP IS COMPLETE.
WEAR CHEM RESIST GLASSES , GLOVES & CLTHG. WEAR NIOSH APPRVD RESP.
Neutralizing Agent:NEUTRALIZE W/SODA ASH, LIMESTONE, ETC.
====================== Handling and Storage ======================
Handling and Storage Precautions:HYDROCHLORIC ACID WILL ATTACK MOST
METALS & SOME FORMS OF PLASTICS, RUBBER & COATINGS. STORE AT ROOM
TEMPERATURE. KEEP TIGHTLY SEALED WHEN NOT IN USE.
Other Precautions:IRRITANT. CORROSIVE LIQUID. AVOID INHALATION,
INGESTION & CONTACT W/EYES & SKIN.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WEAR NIOSH APPROVED RESPIRATOR.
Ventilation:USE IN A CHEMICAL FUME HOOD.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS &(SUPDAT)
Other Protective Equipment:ANSI APPROVED EYE WASH FOUNTAIN & DELUGE
SHOWER . WEAR CHEMICAL RESISTANT CLOTHING. LAB COAT.
Work Hygienic Practices:WASH CAREFULLY AFTER USE.
Supplemental Safety and Health
MATLS TO AVOID:COMES INTO CONT W/MOST METALS IT CORRODES THEM SEVERELY
& FORMS FLAMM HYDROGEN GAS. CONT W/ANY ALKALI/ACTIVE METAL MAY
DEVEL ENOUGH HEAT TO CAUSE FIRE IN ADJACENT COMBUST MATL. EYE PROT
:FULL LGTH FSHLD . EFTS OF OVEREXP:EYES, MUC MEMBS, SKIN & UPPER
RESP TRACT. WHEN CONC HYDROCHLORIC ACID IS(ING 4)
================== Physical/Chemical Properties ==================
Spec Gravity:1
Solubility in Water:SOLUBLE
Appearance and Odor:TRANSPARENT SOLUTION W/ACRID ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
BASES, AMINES, ALKALI METALS, COPPER, COPPER ALLOYS, ALUMINUM & HCL
CORRODES STEEL. WHEN CONC HYDROCHLORIC ACID (SUPDAT)
Stability Condition to Avoid:ELEVATED TEMPERATURES MAY CAUSE CONTAINERS
TO BURST & LIBERATE TOXIC FUMES OF HYDROGEN CHLORIDE GAS.
Hazardous Decomposition Products:WILL RELEASE TOXIC FUMES OF HYDROGEN
CHLORIDE GAS.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . CONTACT LOCAL HAZARDOUS OR CHEMICAL WASTE DISPOSAL
AGENCY FOR REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|