===================== Product Identification =====================
MSDS NAME:LIQUID HARDENER, 27325
NIIN:00N078928
MSDS Number: CGGRT
=== Responsible Party ===
Company:CATALYST SYSTEMS INC, U.S. CHEMICALS & PLASTICS
Address:2290 ZIMMERMAN RD SE
Box:88
City:GNADENHUTTEN
State:OH
ZIP:44629
Country:US
Info Phone Num:614-254-4311
Emergency Phone Num:614-254-4311;800-424-9300(CHEMTREC)
CAGE:DO111
=== Contractor Identification ===
Company:CATALYST SYSTEMS INC
Address:P O BOX 165
Box:88
City:GNADENHUTTEN
State:OH
ZIP:44629-0165
Phone:614-254-4311
CAGE:DO111
============= Composition/Information on Ingredients =============
Name:2-BUTANONE, PEROXIDE; (METHYL ETHYL KETONE PEROXIDE) (MEKP)
(CERCLA)
CAS:1338-23-4
RTECS #:EL9450000
Fraction by Wt: 30-35%
OSHA PEL:C 0.7 PPM
ACGIH TLV:C 0.2 PPM
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS
Name:HYDROGEN PEROXIDE, 3%; (HYDROGEN PEROXIDE) (SARA 302)
CAS:7722-84-1
RTECS #:MX0887000
Fraction by Wt: 0-5%
OSHA PEL:1 PPM
ACGIH TLV:1 PPM
Name:PHTHALIC ACID, DIMETHYL ESTER; (DIMETHYLPHTHALATE) (SARA
313) (CERCLA)
CAS:131-11-3
RTECS #:TI1575000
Fraction by Wt: 45-50%
OSHA PEL:5 MG/M3
ACGIH TLV:5 MG/M3
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:1,3-PENTANEDIOL, 2,2,4-TRIMETHYL-, DIISOBUTYRATE (ESTER);
(2,2,4-TRIMETHYLPENTANEDIOL-1,3- DIISOBUTYRATE)
CAS:6846-50-0
RTECS #:SA1420000
Fraction by Wt: 15-20%
OSHA PEL:5 MG/M3
ACGIH TLV:5 MG/M3
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50:(ORAL,RAT) 1017 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES: CAN CAUSE IMMED SEV RXN &
MAY RSLT IN LOSS OF FUNCTIONAL VISION. MAY CAUSE DELAYED KERATITIS.
SKIN: CAN CAUSE IRRIT, (MINOR ITCHING, BURNING AND/OR REDNESS),
DERM, DEFAT MAY BE READILY AB SORBED THRU SKIN. INHAL: CAN CAUSE
NASAL & RESP IRRIT, DIZZ, WEAK, FATG, NAUS, HDCH, POSS UNCON AND/OR
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: ASPHY. ASPIR OF MATL INTO LUNGS MAY
RSLT IN CHEM PNEUM WHICH CAN BE FATAL. INGEST: CAN CAUSE GI IRRIT,
NAUS, VOMIT, DIARR. CHRONIC: OVEREXP TO MATL HAS APPARENTLY BEEN
KNOWN TO CAUSE FOLLOWI NG EFTS IN LAB ANIMALS: EYE/SKIN DMG,
CYTOGENETIC EFTS. TRACE AMTS OF SOME CHEMS KNOWN TO STATE OF
CALIFORNIA (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL: REMOVE TO WELL-VENTILATED AREA. MAKE COMFORTABLY WARM,
BUT NOT HOT. USE OXYG/ARTF RESP AS REQD. CONSULT PHYS. SKIN: WASH
PROMPTLY W/SOAP AND EXCESS WATER. EYE: FLUSH PROMPTLY W/EXCESS
WATER FOR AT LEAST 15 MINUTES. CONSULT PHYS. INGEST: DO NOT INDUCE
VOMITING. GIVE VICTIM GLASS OF WATER. CALL PHYS IMMEDIATELY.
===================== Fire Fighting Measures =====================
Flash Point Method:SCC
Flash Point:180F,82C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . FIGHT LIKE A FUEL OIL FIRE. COOL FIRE EXPOSED
CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS EXPOSED TO HIGH
TEMPERATURES, SUCH AS FIRE CONDITIONS MAY RUPTURE.
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE AREA. REMOVE ALL POSSIBLE SOURCES OF
IGNITION. AVOID PROLONGED BREATHING OF VAPOR. CONTAIN SPILL WITH
INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:USE WITH ADEQUATE VENTILATION. AVOID
CONT W/EYES AND SKIN. AVOID BREATHING VAPORS. DO NOT STORE PRODUCT
>100F/38C.
Other Precautions:DO NOT FLAME, CUT, BRAZE WELD OR MELT EMPTY
CONTAINERS. KEEP PROD AWAY FROM HEAT, OPEN FLAME, AND OTHER SOURCES
OF IGNITION. AVOID CONT W/STRONG ACIDS, ALKALIES AND OXIDIZERS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF COMPONENT TLV LIMITS ARE EXCEEDED, USE NIOSH
APPRVD RESPIRATOR TO REMOVE VAPORS. USE NIOSH APPRVD AIR-SUPPLIED
RESPIRATOR IF NECESSARY.
Ventilation:USE ADEQ VENT IN VOLUME & PATTERN TO KEEP TLV/PEL BELOW REC
LEVELS. EXPLOSION-PROOF VENTILATION MAY BE NECESSARY.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS (SUPDAT).
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . WEAR
PROT CLTHG AS REQD TO PREVENT SKIN CONT. SOLVS MAY BE
ABSORBED(SUPDAT)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EVAP RATE:SLOWER THAN ETHYL ETHER (ETHYL ETHER =1). % VOLAT BY
WEIGHT:NEGLIGIBLE. EFTS OF OVEREXP:TO CAUSE CANCER, BIRTH
DEFECTS/OTHER REPROD HARM MAY BE PRESENT IN THIS PROD. EYE PROT:&
FULL LENGTH F ACESHIELD . OTHER PROT EQUIP:THROUGH THE SKIN.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:DECOMPOSES
Vapor Pres:0.1
Vapor Density:HVR/AIR
Spec Gravity:1.17
Evaporation Rate & Reference:SUPP DATA
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR OR RED LIQUID W FAINT KETONE ODOR.
Percent Volatiles by Volume:SUPDAT
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, ALKALIES, OXIDIZERS.
Stability Condition to Avoid:STABLE @ AMBIENT TEMPS, BUT MAY DECOMPOSE
@ TEMPS >131F. OPEN FLAMES, SPARKS, HEAT, ELECTRICAL AND STATIC
DISCHARGE.
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE AND
CARBON.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE, AND
FEDERAL REGULATIONS.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|