Search   
MSDS  
:
 LEAD ACID STORAGE BATTERY
CAS  
:
 7439-92-1
7440-36-0
7440-38-2
7664-93-9
7440-70-2
NAME  
:
 lead (sara 313) (cercla)
antimony (sara 313) (cercla)
arsenic (sara 313) (cercla)
sulfuric acid (sara 302/313) (cercla)
calcium, metal
=====================  Product Identification  =====================

MSDS NAME:LEAD ACID STORAGE BATTERY
NIIN:01-032-1326
MSDS Number: CGLDW
=== Responsible Party ===
Company:DOUGLAS BATTERY MFG CO
Address:500 BATTERY DR
Box:12159
City:WINSTON-SALEM
State:NC
ZIP:27107
Country:US
Info Phone Num:800-368-4527
Emergency Phone Num:910-650-7000 800-424-9300(CHEMTREC)
Preparer's Name:ALAN L. CSORITAS
CAGE:63432
=== Contractor Identification ===
Company:BATTERIES PLUS (414-498-1100)
Box:UNKNOW
CAGE:0YUR5
Company:DOUGLAS BATTERY MFG CO
Address:500 BATTERY DR
Box:12159
City:WINSTON-SALEM
State:NC
ZIP:27107
Country:US
Phone:800-368-4527
CAGE:63432
Company:NAMCON INC (804-460-0879)
Box:UNKNOW
CAGE:3X778

=============  Composition/Information on Ingredients  =============

Name:LEAD (SARA 313) (CERCLA)
CAS:7439-92-1
RTECS #:OF7525000
Fraction by Wt: 60%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:SEE 1910.1025
ACGIH TLV:0.05MG/M3, A3; 9596
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Name:ANTIMONY (SARA 313) (CERCLA)
CAS:7440-36-0
RTECS #:CC4025000
Fraction by Wt: 1-5%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.5 MG/M3
ACGIH TLV:0.5 MG (SB)/M3; 9596
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Name:ARSENIC (SARA 313) (CERCLA)
CAS:7440-38-2
RTECS #:CG0525000
Fraction by Wt: <1%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:SEE 1910.1018
ACGIH TLV:0.01 MG/M3, A1; 9596
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Name:SULFURIC ACID (SARA 302/313) (CERCLA)
CAS:7664-93-9
RTECS #:WS5600000
Fraction by Wt: 10-38%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3/3 STEL; 9596
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Name:CALCIUM, METAL
CAS:7440-70-2
RTECS #:EV8040000
Fraction by Wt: <0.15%
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:TLV FOR SULFURIC ACID IS 1 MG/M3
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:YES	 OSHA:NO
Health Hazards Acute and Chronic:CONTENTS OF BATTERY ARE CORROSIVE
    EYES: MAY CAUSE IRRITATION.SKIN:MAY CAUSE IRRITATION AND
    BURNS.INGEST:MAY CAUSE GI TRACT IRRITATION.INHAL:MAY CAUSE
    RESPIRATORY IRRITATION.CHRONIC:DRYING OF THE SKIN,
    BRONCHITIS,EROSION OF TOOTH ENAMEL.
Explanation of Carcinogenicity:SULFURIC ACID MISTS-IARC 2B.LEAD-IARC
    2B.
Effects of Overexposure:SKIN:DERMATITIS.
Medical Cond Aggravated by Exposure:SULFURIC ACID MISTS MAY BRONCHIAL
    SYSTEM, SKIN AND EYES.

=======================  First Aid Measures  =======================

First Aid:SKIN:REMOVE CONTAMINATED CLOTHING;WASH WITH WATER.GET MEDICAL
    ATTENTION.EYES:FLUSH WITH WATER FOR 15 MINUTES.GET MEDICAL
    ATTENTION.INHAL:REMOVE TO FRESH AIR.GIVE OXYGEN OR ARTIFICIAL
    RESPIRATION IF NE EDED.INGEST:DO NOT INDUCE VOMITING.GET PROMPT
    QUALIFIED MEDICAL ATTENTION.IF CONSCIOUS,RINSE MOUTH WITH WATER.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Autoignition Temp:Autoignition Temp Text:675F
Lower Limits:4.1(H2)
Upper Limits:74.2(H2)
Extinguishing Media:HALON,DRY CHEMICAL.
Fire Fighting Procedures:USE A SELF-CONTAINED BREATHING APPARATUS AND
    FULL PROTECTIVE EQUIPMENT.COOL FIRE EXPOSED CONTAINERS WITH WATER
    FOG.ACID MISTS ARE CORROSIVE.
Unusual Fire/Explosion Hazard:HYDROGEN GAS AND SULFURIC ACID MISTS MAY
    BE PRESENT.

==================  Accidental Release Measures  ==================

Spill Release Procedures:ELIMINATE SOURCES OF IGNITION.USE PROPER
    RESPIRATORY AND PROTECTIVE EQUIPMENT.NEUTRALIZE.SOAK UP WITH A NON-
    COMBUSTIBLE INERT ABSORBANT(CLAY,SAND);PLACE IN PROPER CONTAINER
    FOR DISPOSAL.AVOID SHORTIN G BATTERY TERMINALS.
Neutralizing Agent:SODA BICARBONATE,SODA ASH,SAND,LIME SHOULD BE KEPT
    ON SITE FOR SPILL REMEDIATION

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL,DRY,WELL-VENTILATED
    PLACE. KEEP CONTAINER CLOSED WHEN NOT IN USE.KEEP AWAY FROM
    HEAT,SPARKS,FLAMES AND INCOMPATIBLE MATERIALS.
Other Precautions:AVOID SHORTING BATTERY TERMINALS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:WHERE ENVIRONMENTAL CONTROLS ARE LACKING OR IN
    ENCLOSED SPACES USE EITHER A SELF-CONTAINED BREATHING APPARATUS OR
    A NIOSH/ MSHA APPROVED RESPIRATOR FOR ACID GAS,DEPENDING ON THE
    AIRBORN CONCENTRATION.
Ventilation:USE GENERAL DILUTION VENTILATION(4 AIR CHANGES PER HOUR).
Protective Gloves:ACID RESISTANT RUBBER OR PLASTIC
Eye Protection:CHEMICAL SPLASH GOGGLES
Other Protective Equipment:PROTECTIVE CLOTHING,AS NEEDED.PROVIDE A
    LOCAL EYE WASH STATION AND SAFETY SHOWER.
Work Hygienic Practices:WASH HANDS.SEPERATE WORK CLOTHES FROM STREET
    CLOTHES.LAUNDER WORK CLOTHES BEFORE REUSE.KEEP FOOD OUT OF THE WORK
    AREA.
Supplemental Safety and Health
NONE

==================  Physical/Chemical Properties  ==================

HCC:C1
Boiling Pt:B.P. Text:275F,135C
Melt/Freeze Pt:M.P/F.P Text:>320F,>160C
Vapor Density:3.4
Spec Gravity:1.08-1.4
pH:ACID
Solubility in Water:ELECTROLYTE-COMPLETE
Appearance and Odor:BATTERY WITH POLYPROPYLENE OR HARD RUBBER CASE.
    ELECTROLYTE IS COLORLESS ACID.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:OVERCHARGING,SOURCES OF IGNITION.
Hazardous Decomposition Products:EXPLOSIVE HYDROGEN/OXYGEN FORMED
    BATTERY DURING CHARGING.SULFURIC ACID
    MISTS,SO2,SO3,STILBENE,ARSINE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:RECYCLE WHOLE SCRAP BATTERIES TO LEAD SMELTER.
    PLACE NEUTRALIZED SPILLS IN CONTAINER WITH SORBENT
    MATERIALS.DISPOSE OF IN ACCORDANCE WITH FEDERAL,STATE AND LOCAL
    REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
LIQUI-MOLY
FERRIC CHLORIDE,ANHYDROUS 7705-08-0
7758-94-3
LIQUA-TOX II 82-66-6
PETROLEUM ETHER 8032-32-4
ARGON, COMPRESSED 7440-37-1
ALKALINE BATTERIES,NO MERCURY FORMULA-AN ARTICLE 1313-13-9
7439-89-6
7440-66-6
7732-18-5
1310-58-3
7440-44-0
7727-43-7
#14AM MAGNAGLO PREPARED BATH 8042-47-5
124-38-9
ISOPROPANOL 99% 67-63-0
NITROCELLULOSE MEMBRANE FILTERS 9004-70-0
9004-35-7
CALCIUM SULFATE, ANHYDROUS, POWDER 7778-18-9
WELDING FLUX 14075-53-7
1332-77-0
10043-35-3
14075-53-7
AIR 7727-37-9
7782-44-7
PURPLE K DRY CHEMICAL 12001-26-2
298-14-6
DRY CHARGED BATTERY--NO ELECTROLYTE ADDED 7439-92-1
7440-36-0
7440-38-2
7440-70-2
7440-31-5
9003-07-0
9003-07-0
9540-01;POLYBROMIDE RESIN 60177-39-1
7726-95-6
7732-18-5
LEAD ACID STORAGE BATTERY 7439-92-1
7440-36-0
7440-38-2
7664-93-9
7440-70-2
DTE 13M 7440-66-6
68649-42-3
SODIUM PHOSPHATE, TRIBASIC 7601-54-9
PC:15216 CAUSTIC SODA SOLUTION 50%,REGULAR GRADE 1310-73-2
497-19-8
7647-14-5
7732-18-5
5090 HYDROCHLORIC ACID, 6N (1:1) 7647-01-0
SEALED MAINTENANCE FREE LEAD ACID BATTERIES 7439-92-1
7664-93-9
25038-60-2
CADNICA 1.2V, NICKEL CADMIUM BATTERY 7440-43-9
21041-95-2
7440-02-0
12054-48-7
1310-58-3
DARINA EP GREASE 1302-78-9
15890-25-2
NICKEL CADMIUM AIRCRAFT BATTERY; 023564-000 1313-99-1
1310-58-3
1306-19-0
7440-50-8
NICKEL CADMIUM SEALED CELL BATTERY 7440-43-9
21041-95-2
1306-19-0
7440-02-0
12054-48-7
1313-99-1
1310-58-3
7440-48-4
118537 SCENTS-IT
WINDOW LIFTS CYLINDER 8012-95-1
7727-37-9
05089 BRAKLEEN AEROSOL 71-55-6
127-18-4
646-06-0
124-38-9
MIL-C-46168D PART B 4:1 BLEND
NRC P/N B7760,CAP,RADIACMETER 7440-29-1
LITHIUM THIONYL CHLORIDE BATTERY 7719-09-7
7439-93-2
1201,GLYPTAL,AIR DRY ENAMAL. 1330-20-7
8030-30-6
64741-41-9
1309-37-1
14807-96-6
EPOXY CUP,EPOXY RESIN,GLUE,PART A,RESIN
EPOXY CUP,EPOXY RESIN,GLUE,PART B,HARDENER
FLAW-FINDER AG-1-DH DEVELOPER
ZYGLO DEVELOPER ZP-9F 67-64-1
67-63-0
115-77-5
124-38-9
072012-13 CARTRIDGE; ELECTRO PYROTECHNIC CARTRIDGE & BYPRODS 121-82-4
122-39-4
9004-70-0
7778-74-7
7440-32-6
VALVE REGULATED LEAD-ACID BATTERY (BATT ASSEMBLY 8565) 7439-92-1
7664-93-9
7440-38-2
7440-70-2
36400020-2,FIRE EXTINGUISHER,HALON 1301 75-63-8
12314494-2(TACOM MODEL);36400010-2(RYAN,FB MODEL) 75-63-8
12314494-2,FIRE EXTINGUISHER,HALON 1301 75-63-8
ZEROSTART STARTING FLUID-CYLINDER 124-38-9
60-29-7
142-82-5
64742-53-6
LEAD/ACID STORAGE BATTERY, NW25811 7439-92-1
7440-36-0
7440-38-2
7664-93-9
7440-70-2
SELF-LUMINOUS DEVICE (GAS FILLED) 10028-17-8
WRIST WATCH,SELF LUMINOUS,MIL-W-46374 10028-17-8
DUBL-CHEK REMOVER DR-60 64742-88-7
WRIST WATCH TYPE I 10028-17-8
RARUS 427 119-06-2
CONOSOL C-200 64742-47-8
AI 8493-2 AIRFORCE TYPE II 1344-09-8

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net