===================== Product Identification =====================
MSDS NAME:CADNICA 1.2V, NICKEL CADMIUM BATTERY
NIIN:01-102-4500
MSDS Number: CGLFD
=== Responsible Party ===
Company:SANYO ENERGY USA CORP
Address:2001 SANYO AVE
City:SAN DIEGO
State:CA
ZIP:92173
Country:US
Info Phone Num:619-661-6620
Emergency Phone Num:619-661-6620
CAGE:00JU0
=== Contractor Identification ===
Company:DUNN R G ASSOCIATES INC
Address:15104 LEE RD SUITE 203-B
Box:City:HUMBLE
State:TX
ZIP:77396-2078
Country:US
Phone:281-441-2001/FAX: 281-441-7772
CAGE:0A272
Company:SANYO ENERGY(U.S.A.) CORP.
Address:2001 SANYO AVE
Box:City:SAN DIEGO
State:CA
ZIP:92173
Country:US
Phone:619-661-6620
CAGE:00JU0
============= Composition/Information on Ingredients =============
Name:CADMIUM (SARA 313) (CERCLA)
CAS:7440-43-9
RTECS #:EU9800000
Fraction by Wt: 11-26%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.2 MG/M3 DUST; Z-2
ACGIH TLV:0.01 MG/M3 DUST;9596
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS
Name:CADMIUM HYDROXIDE
CAS:21041-95-2
Fraction by Wt: 11-26%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.05 MG CD/M3
ACGIH TLV:0.05 MG CD/M3
Name:NICKEL (SARA 313) (CERCLA)
CAS:7440-02-0
RTECS #:QR5950000
Fraction by Wt: 8-17%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3; 9596
Name:NICKEL HYDROXIDE (SARA 313) (CERCLA)
CAS:12054-48-7
RTECS #:QR7040000
Fraction by Wt: 5-12%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1 MG(NI)/M3
ACGIH TLV:0.1 MG(NI)/M3; 9596
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS
Name:POTASSIUM HYDROXIDE (CERCLA)
CAS:1310-58-3
RTECS #:TT2100000
Fraction by Wt: <3%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:C 2 MG/M3
ACGIH TLV:C 2 MG/M3; 9596
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:BATT CELL SHOULDNT BE OPN/EXPO TO HEAT
BECAUSE EXPO TO INGREDS CONTAINED W/IN COULD BE HARMFUL UNDER SOME
CIRCUMSTANCES.BATT BREACH-INHAL:CD DUST/FUME EMITTED-THRAOT
DRYNESS,RESP IRRIT,HEAD,NAU,VOMIT, CHEST PAIN,EXT
RESTLESSNESS,IRRITABILITY,PNEUITIS,BRONCHOPNEU,HI CONC
DEATH.INGEST:LOCALIZED BURNS,INCR (SUPPLEMENTAL)
Explanation of Carcinogenicity:PER MSDS:NTP-CD,NI CARC;EPA-CD
B1;IARC-CD 2A;ACGIH-CD A2.
Effects of
Overexposure:HEALTH:SALIVATION,CHOKING,NAU,PERSISTENT,VOMIT,DIARR,A
BD PAIN,ANEMIA,TENEAMUS,KID DISFUNCTION.NO SKIN
ABSORPTION.SKIN:CHEM BURNS,DERM IN SENSITIVE INDIVIDUALS.EYE:SEVERE
IRRIT,CHEM BURNS. REP OVEREXPO TO CD LUNG CANC,LUNG/KID/LIVER
DISFUNCTION,SKELETAL DISEASE,REPRD TOXICITY.CHRONIC OVEREXPO TO NI
CANC,DERM.
Medical Cond Aggravated by Exposure:KNOWLEDGE OF AVAI TOXICOLOGY INFO &
PHYS & CHEM PROPERTIES OF MATL SUGGESTS THAT OVEREXPO IN UNLIKELY
TO AGGRAVATE EXISTING MED CONDITIONS.
======================= First Aid Measures =======================
First Aid:INGEST:DONT INDUCE VOMIT.SEEK MED ATTN IMMED.SKIN:OPN BATT
CONTACT SKIN IMMED LFUSH W/H2O FOR @LEAST 15MINS.INHAL:REMOVE IMMED
TO FRESH AIR.SEEK MED ATTN.EYE:OPN BATT CONTACT EYES IMMED FLUSH
EYES W/H 2O CONT FOR @LEAST 15MINS.SEEK MED ATTN.
===================== Fire Fighting Measures =====================
Flash Point:NA
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:ANY CLASS OF EXTINGUISHING MEDIUM MAY BE USED ON
BATTERIES OR THEIR PACKING MATERIAL.
Fire Fighting Procedures:EXPO TO TEMP OF >212F CAN CAUSE EVAPO OF
LIQ(KOH ELECTRO)RESULT IN CELL RUPTURE.POT FOR EXPO TO CD FUMES
DUING FIRE;USE SCBA.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
================== Accidental Release Measures ==================
Spill Release Procedures:SPILL/LEAK UNLIKELY-CELLS CONTAIN IN
HERMETICALLY SEALED CASE.CASE BREACH DON PROT CLOTH IMPERV TO
CAUSTIC MATLS.ABSORB/PACK RESIDUE IN INERT MATL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COOL PLACE,PREVENT CONDENS ON
CELL/BATT TERMINALS.ELEV TEMPS RESULT IN RED BATT LIFE.OPTIMUM
STORAGE TEMP:31F-95F.DONT SHAKE BATT IN BULK CNT
Other Precautions:CONCEN OF INGREDS VARY DEPENDING ON STATE OF CHARGE
OR DISCHARGE.ENCAP/SEAL REQMT & SOLDER/WELD ALL SANYO FOR HAZ
PRECAUT/LIMITATIONS.DONT INCINERATE/SUBJ TO TEMP >212F-CAN VAPORZIE
LIQ CAUSE CELL RUP TURE.INCINERATION MAY CAUSE CD EMISSIONS
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NOT REQUIRED UNDER NORMAL USE.
Ventilation:NOT REQUIRED UNDER NORMAL USE.
Protective Gloves:NOT REQUIRED UNDER NORMAL USE.
Eye Protection:NOT REQUIRED UNDER NORMAL USE.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:BATT DESIGNED FOR RECHARGING.CHARGE BATT BEF
USE.OBSERVE SPEC CHARGE RATE.
Supplemental Safety and Health
DURING NORMAL USE HAZ MATLS FULLY CONTAINED INSIDE BATT CELL.EXPO TO
FIRE/EXPLO/EXTREME ABSUE/MISUSE/IMPROPER DISPO RESULT IN BREACHING
BATT CELL CASE HAZ MATLS MAY BE RELEASED.
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:NP
Melt/Freeze Pt:M.P/F.P Text:NP
Decomp Temp:Decomp Text:NP
Vapor Pres:NP
Vapor Density:NP
Spec Gravity:NP
pH:NP
Viscosity:NP
Evaporation Rate & Reference:NP
Solubility in Water:NP
Appearance and Odor:MFG ARTICEL PER 29CFR1910.1200.BATT CELL IN
HERMETICALLY-SEALED CASE.
Percent Volatiles by Volume:NP
Corrosion Rate:NP
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
BATT CELL IN ENCASED IN NON-REACTIVE CNTNR;BREACHED-AVOID INTERNAL BATT
CONTACT W/ACIDS,ALDEHYDES,CARBAMATE CMPDS.
Stability Condition to Avoid:HEAT,OPN FLAMES,SPARKS,MOISTURE.RE.AVOID
PROL SHORT CIRCUIT-HEAT BURN SKIN,RUPTURE BATT CASE.
Hazardous Decomposition Products:OXIDES OF CADMIUM & NICKEL.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPO OF AS HAZ WASTE IAW APPLIC STATE/FED
REGS.RESULTANT SPILL RESIDUES MAY BE CHARACTER AS
D002(CAUSTIC),D005(CD)PER RCRA.RETURN TO SANYO FOR RECYCLE.CALL
SANYO REP FOR INFO ON EARTHSAVER 2001 RECYC L PROGRAM.BATT HNDLG
IAW ALL STATE/FED LAWS/REGS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|