===================== Product Identification =====================
MSDS NAME:12314494-2(TACOM MODEL);36400010-2(RYAN,FB MODEL)
NIIN:01-269-8376
MSDS Number: CGLGB
=== Responsible Party ===
Company:PACIFIC SCIENTIFIC CORP
Address:HIGHWAY 52 NW
Box:2200
City:WEST LAFAYETTE
State:IN
ZIP:47906
Country:US
Info Phone Num:317-463-2511
Emergency Phone Num:501-862-5141
CAGE:05167
=== Contractor Identification ===
Company:PACIFIC SCIENTIFIC CO HTL/KIN-TECH DIVISION
Address:1800 HIGHLAND AVE
Box:City:DUARTE
State:CA
ZIP:91010
Country:US
Phone:818-359-9317/602-796-1100
CAGE:05167
Company:RYAN F B MFG CO INC
Box:451
City:CHARITON
State:IA
ZIP:50049-0451
Country:US
Phone:602-961-1100
CAGE:01567
Company:U S ARMY TANK AUTOMOTIVE COMMAND AMSTA-TFP
Address:11 MILE RD
Box:City:WARREN
State:MI
ZIP:48397
Country:US
Phone:AV 786-6293 MSDS CALL SKIP ROBERTS
CAGE:19207
============= Composition/Information on Ingredients =============
Name:BROMOTRIFLUOROMETHANE (HALON 1301) (SARA 313) (CERCLA)
CAS:75-63-8
RTECS #:PA5425000
Fraction by Wt: 100%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM; 9495
Ozone Depleting Chemical:1
===================== Hazards Identification =====================
LD50 LC50 Mixture:LC50 RATS= >800,000 PPM FOR FOUR HOURS.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE/CHRONIC: PRODUCT HAS ANESTHETIC
AND CARDIAC EFFECTS IN HUMANS AT CONCENTRATIONS ABOVE 10% BY
VOLUME, CONCENTRATIONS BELOW 10% CONSIDERED SAFE FOR 0-5 MINUTE
EXPOSURES.PRODUCT CLASSIFIED AS GROUP 6 (LEAST TOXIC) IN
UNDERWRITERS LABORATORIES CLASSIFICATION OF COMPARATIVE LIFE
HAZARDS OF FIRE EXTINGUISHING AGENTS.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:ANESTHETIC EFFECT AT LEVELS BELOW 10% IS
SIMILAR TO A FEELING OF MILD INTOXICATION. ANESTHETIC EFFECTS END
RAPIDLY AFTER EXPOSURE IS TERMINATED. PROLONGED EXPOSURE TO
CONCENTRATIONS ABOVE 10% (15-20%) MAY LEAD TO UNCONSCIOUSNESS AND
POSSIBLY DEATH.
Medical Cond Aggravated by Exposure:CARDIAC CONDITIONS MAY BE
AGGRAVATED BY OVEREXPOSURE.
======================= First Aid Measures =======================
Eyes: FLUSH WITH WATER. GET MEDICAL ATTENTION. SKIN: FLUSH
WITH WATER. GET MEDICAL ATTENTION IF FROSTBITE OCCURS. INHALATION:
MOVE TO FRESH AIR. IF NOT BREATHING, GIVE CPR. IF BREATHING
DIFFICULT, GIV E OXYGEN. GET MEDICAL ATTENTION. NOTE: EPINEPHRINE
IS CONTRAINDICATED IN THE TREATMENT OF OVER-EXPOSURE TO THIS
PRODUCT.
===================== Fire Fighting Measures =====================
Flash Point:NON-FLAMMABLE
Extinguishing Media:HALON 1301 IS EXTINGUISHING AGENT. USE WATER SPRAY
TO COOL CYLINDERS INVOLVED IN FIRES.USE MEDIA SUITABLE FOR AREA
FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:ABOVE 1000F, HALON 1301 MAY RELEASE
HYDROGEN FLUORIDE, HYDROGEN BROMIDE, CARBONYL FLUORIDE AND CARBONYL
BROMIDE.
================== Accidental Release Measures ==================
Spill Release Procedures:EVACUATE AREA. WEAR SELF-CONTAINED BREATHING
APPARATUS. VENTILATE ENCLOSED AREAS IN CASE OF DISCHARGE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:PROTECT EXTINGUISHERS AND CYLINDERS
FROM PHYSICAL DAMAGE. STORAGE TEMPERATURE SHOULD NOT EXCEED 125F.
Other Precautions:CYLINDERS SHOULD BE SECURED FOR STORAGE WITH VALVE
PROTECTION CAP IN PLACE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WEAR NIOSH APPROVED, SELF-CONTAINED BREATHING
APPARATUS AT CONCENTRATIONS GREATER THAN 10,000 PPM AS RECOMMENDED
BY NIOSH. CONSULT ANSI STANDARD AND OSHA REGULATIONS CONCERNING THE
USE OF RESPIRATORY EQUIPMENT. AVOID PROLONGED EXPOSURE.
Ventilation:MATERIAL TRANSFER AND HANDLING SHOULD BE CONDUCTED WITH AN
EXHAUST SYSTEM.
Protective Gloves:WEAR GLOVES TO PROTECT AGAINST FROSTBITE
Eye Protection:WEAR CHEMICAL SAFETY GOGGLES.
Other Protective Equipment:DO NOT WEAR CONTACT LENSES.
Work Hygienic Practices:CHECK THAT PIPING IS EMPTY BEFORE DOING
MAINTENANCE WORK. PERIODICALLY CHECK CYLINDERS TO ENSURE VALVES ARE
NOT LEAKING.
Supplemental Safety and Health
NONE
================== Physical/Chemical Properties ==================
HCC:G3
Boiling Pt:B.P. Text:-72F,-58C
Melt/Freeze Pt:M.P/F.P Text:-270F,-168C
Vapor Pres:6200 AT 0C
Vapor Density:5.1
Spec Gravity:1.57 AT 20C
Solubility in Water:0.03% BY WEIGHT
Appearance and Odor:COLORLESS GAS. ODORLESS.
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ACTIVE METALS, FIRES OF METAL HYDRIDES, MATERIAL CONTAINING OWN OXYGEN.
PRODUCT MAY DEGRADE CERTAIN POLYMERIC MATERIALS.
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:HYDROGEN FLUORIDE, HYDROGEN BROMIDE,
BROMINE, CARBONYL FLUORIDE, CARBONYL BROMIDE. SMOKING CAN FORM
THESE CHEMICALS.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
==================== Disposal Considerations ====================
Waste Disposal Methods:HALON 1301 IS RECYCLED.CONTACT THE DLA ODS
POLICY GROUP AT DEFENSE SUPPLY CENTER RICHMOND.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|