===================== Product Identification =====================
MSDS NAME:804868, CALIBRATION CHECK GAS, 100 PPM (SUPDAT)
NIIN:00N085093
MSDS Number: CGZYN
=== Responsible Party ===
Company:MINE SAFETY APPLIANCES CO
Box:426
City:PITTSBURGH
State:PA
ZIP:15230
Country:US
Info Phone Num:412-967-3800
Emergency Phone Num:412-967-3800
CAGE:8F723
=== Contractor Identification ===
Company:MINE SAFETY APPLIANCES CO
Address:121 GAMMA DR
Box:426
City:PITTSBURGH
State:PA
ZIP:15230-0426
Country:US
Phone:724-733-9270
CAGE:8F723
============= Composition/Information on Ingredients =============
Name:METHANE, CHLORODIFLUORO-; (CHLORODIFLUOROMETHANE) (SARA
313) (CERCLA)
CAS:75-45-6
RTECS #:PA6390000
Fraction by Wt: 0.01%
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM
Ozone Depleting Chemical:2
Name:NITROGEN
CAS:7727-37-9
RTECS #:QW9700000
Fraction by Wt: BALANCE
OSHA PEL:N/K
ACGIH TLV:ASPHYXIANT
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: NONE KNOWN FOR 100 PPM 4-22.
NITROGEN IS AN ASPHYXIANT. SIGNIFICANT DILUTION OF AMBIENT AIR BY
ASPHYXIANTS CAUSE AIR HUNGER, INCREASED BREATHING FREQUENCY,
DROWSINESS, WEAKNESS, AND RINGING IN EAR. CHLOROFLUOROCARBON (CFC)
MATERIALSHAVE PRODUCED SENSITIZATION OF THE MYOCARDIUM TO
EPINEPHRINE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: IN LABORATORY ANIMALS AND COULD HAVE
A SIMILAR EFFECT IN HUMANS. ADRENOMIMETICS (I.E., EPINEPHRINE) MAY
BE CONTRA-INDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS
ACUTELY OR CHRONICALLY E XPOSED TO CFCS. TARGET ORGANS: LUNGS.
Medical Cond Aggravated by Exposure:NO INFORMATION.
======================= First Aid Measures =======================
First Aid:INGEST:CALL MD IMMEDIATELY . EYES:IMMEDIATELY FLUSH EYES
W/POTABLE WATER FOR AT LEAST 15 MINUTES, SEEK ASSISTANCE FROM MD .
SKIN:FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD. . INHAL: R EMOVE
VICTIM FROM EXPOSURE. IF NOT BREATHING, GIVE ARTIFICIAL
RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN. GET MEDICAL
ATTENTION IMMEDIATELY.
===================== Fire Fighting Measures =====================
Extinguishing Media:THIS CALIBRATION GAS MIXTURE IS NOT FLAMMABLE.
MEDIA SUITABLE FOR SURROUNDING AREA .
Fire Fighting Procedures:NIOSH/MSHA APPRVD PRESS DEMAND SCBA & FULL
PROT EQUIP . CHLORODIFLUOROMETHANE DECOMPOSES @ HIGH TEMPS YIELDING
TOXIC HALOGEN COMPOUNDS.
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE FLUORIDES, CHLORIDES, AND PHOSGENE . GAS UNDER PRESSURE,
1000 PSIG @ 70F. DO NOT EXCEED 120F.
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE AREA.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COOL, DRY, WELL-VENTILATED
AREA. DO NOT EXCEED 120F. FOLLOW CALIBRATION PROCEDURE DETAILED IN
MSA INSTRUCTION MANUAL PROVIDED WITH (SUPDAT)
Other Precautions:AVOID BREATHING GAS. NO SMOKING IN AREA OF USE. DO
NOT USE IN GENERAL VICINITY OF ARC WELDING, OPEN FLAMES OR HOT
SURFACES. HEAT AND/OR UV RADIATION MAY CAUSE THE FORMATION OF
CHLORIDES, FLUORIDES OR PHOSGEN .
============= Exposure Controls/Personal Protection =============
Respiratory Protection:DUE TO LIMITED AMT OF GAS IN CYL, & LOW RELEASE
RATE EMPLOYED IN INSTRUMENT CALIBRATION, RESP PROT IS NOT INDICATED
UNDER CNDTNS OF INTENDED USE. NIOSH APPROVED RESPIRATORY
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:MECHANICAL VENTILATION IS SUITABLE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED SAFETY GLASSES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:AVOID BREATHING GAS.
Supplemental Safety and Health
MFR TRADE NAME/PART NO: R-22 IN NITROGEN. SOL IN H*2O:
CHLORODIFLUOROMETHANE: APPROX 83 GM3/100 ML(25C). NITROGN: 2.3
CM3/A00 ML(0C). HNDLG/STORAGE: INSTRUMENT UNDER CALIBRATION.
================== Physical/Chemical Properties ==================
Vapor Density:>1
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:SUPP DATA
Appearance and Odor:COLORLESS, ODORLESS GAS MIXTURE.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
AVOID BASES. AVOID POWDERED ACTIVE METALS SUCH AS ALUMINUM, ALKALI
METALS OR ALKALINE EARTH METALS.
Stability Condition to Avoid:COMPRESSED GAS, 1000 PSIG AT 70F.
Hazardous Decomposition Products:CHLORIDES, FLUORIDES AND PHOSGENE .
==================== Disposal Considerations ====================
Waste Disposal Methods:DO NOT PUNCTURE OR INCINERATE CYLINDER. BEFORE
DISCARDING CYLINDER. BEFORE DISCARDING CYL, SLOWLY RELEASE CONTENTS
TO SAFE EXHAUST. DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL, STATE
AND LOCAL REGULAT IONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|