===================== Product Identification =====================
MSDS NAME:MS-7C/ MS-10C HARDENER COMPONENT
NIIN:01-397-3911
Status Code:A
MSDS Number: CLFNG
=== Responsible Party ===
Company:AMERICAN SAFETY TECHNOLOGIES INC
Address:565 EAGLE ROCK AVE
City:ROSELAND
State:NJ
ZIP:07068
Country:US
Info Phone Num:973-403-2600
Emergency Phone Num:1-800-424-9300
Preparer's Name:ERNEST CARTER
Chemtrec Ind/Phone:(800)424-9300
CAGE:88444
=== Contractor Identification ===
Company:AMERICAN SAFETY TECHNOLOGIES INC
Address:565 EAGLE ROCK AVE
Box:City:ROSELAND
State:NJ
ZIP:07068
Country:US
Phone:973-403-2600
CAGE:88444
============= Composition/Information on Ingredients =============
Name:POLYAMIDE/EPOXY ADDUCT
CAS:68424-41-9
Code:F
Minumum % Wt:60.
Maxumum % Wt:80.
Name:AMIDOAMINE RESIN
CAS:68443-08-3
Code:F
Minumum % Wt:5.
Maxumum % Wt:10.
Name:1-METHOXY-2-PROPANOL
CAS:107-98-2
RTECS #:UB7700000
Minumum % Wt:20.
Maxumum % Wt:35.
ACGIH TLV:369 MG/M3;100 PPM
ACGIH STEL:553 MG/M3;150 PPM
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Health Hazards Acute and Chronic:EYES: CAUSES SEVERE IRRITATION OR
BURNS. SKIN: CAUSES SEVERE IRRITATION OR BURNS. INHALATION: MAY
CAUSE UPPER RESPIRATORY TRACT IRRITATION. INGESTION: MAY CAUSE
BURNS OF MOUTH AND THROAT.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, SENSITIZATION AND DERMATITIS.
Medical Cond Aggravated by Exposure:ALLERGY, ECZEMA AND OTHER SKIN
CONDITIONS.
======================= First Aid Measures =======================
Eyes: FLUSH WITH LARGE QUANTITIES OF WATER FOR AT LEAST 15
MINUTES. GET MEDICAL ATTENTION.SKIN: WASH CONTACT AREA WITH MILD
SOAP AND WATER.INHALATION: REMOVE TO FRESH AIR. IF SYMPTOMS PERSIST
CONSULT A PHYSICIAN.INGESTION: DO NOT INDUCE VOMITING. IF
CONSCIOUS , GIVE LARGE QUANTITIES OF WATER TO DILUTE. GET MEDICAL
ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:=34.4C, 94.F
Autoignition Temp:Autoignition Temp Text:NONE
Lower Limits:1.5
Upper Limits:10.9
Extinguishing Media:DRY CHEMICAL, CHEMICAL FOAM, CARBON DIOXIDE OR
WATER.
Fire Fighting Procedures:WEAR COMPLETE PERSONAL PROTECTIVE EQUIPMENT
INCLUDING SELF CONTAINED BREATHING APPARATUS WHERE POTENTIAL FOR
EXPOSURE TO VAPORS OR PRODUCTS OF COMBUSTION EXISTS.
Unusual Fire/Explosion Hazard:DECOMPOSITION AND COMBUSTION PRODUCTS MAY
BE TOXIC.
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. DIKE SPILL.
ABSORB WITH INERT MATERIAL AND COLLECT FOR DISPOSAL. FLUSH
CONTAMINATED AREA WITH DILUTE (5%) ACETIC ACID AND COLLECT RINSAFE
FOR DISPOSAL.
Neutralizing Agent:NONE
====================== Handling and Storage ======================
Handling and Storage Precautions:NONE
Other Precautions:NONE
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR WITH ORGANIC
VAPOR CARTRIDGE IF REQUIRED.
Ventilation:EXPLOSION PROOF MECHANICALVENTILATION AND LOCAL EXHAUST
RECOMMENDED.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL SPLASH PROOF GOGGLES.
Other Protective Equipment:COVERALLS, APRON AND IMPERVIOUS FOOT
COVERING ARE RECOMMENDED.
Work Hygienic Practices:NONE
Supplemental Safety and Health
A SAFETY SHOWER AND EYE WASH FACILITY SHOULD BE AVAILABLE TO EMPLOYEES.
IMMEDIATELY REMOVE AND THOROUGHLY LAUNDER CONTAMINATED CLOTHING
BEFORE REUSE.
================== Physical/Chemical Properties ==================
Boiling Pt:=120.C, 248.F
Melt/Freeze Pt:M.P/F.P Text:NONE
Decomp Temp:Decomp Text:NONE
Vapor Pres:12.5MMHG
Vapor Density:3.12
Spec Gravity:0.96
Evaporation Rate & Reference:0.83 (BUTYL ACETATE=1)
Solubility in Water:PARTIALLY SOLUBLE
Appearance and Odor:AMBER LIQUID, SOLVENT ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:EXCESSIVE HEAT.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
ALDEHYDES AND OXIDES OF NITROGEN.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
=================== Toxicological Information ===================
Toxicological Information:METHYL ISOBUTYL KETONE: LD50 10 G/KG (DER.
RAB.) LC50 4000 PPM (INHALE.RAT) PROPYLENE GLYCOL: LD50 12G/KG
(DERMAL RAB.) LC50 3000 PPM (INHALE. RAT) TITANIUM DIOXIDE: LD50
10G/KG (DERMAL RABBIT), LC50 6820PPM (INHALE, RAT) XYLENE: LD50
3.9G/KG (DERMAL, RABBIT) LC50 6700PPM (INHALE, RAT) EPOXY RESIN:
LD50 20.0G/KG (DERMAL, RABBIT)
===================== Ecological Information =====================
Ecological:EPA WAST NO.: D001
==================== Disposal Considerations ====================
Waste Disposal Methods:THIS PRODUCT., IF DISPOSED AS SHIPPED, MEETS EPA
CRITERIA OF A HAZARDOUS WASTE AS SPECIFIED IN 40 CFR 261 ON THE
BASES OF ITS IGNITABILITY. DISPOSE OF IN A LICENSED HAZARDOUS WASTE
FACILITY IN ACCORDA NCE WITH APPLICABLE LAWS.
=================== MSDS Transport Information ===================
Transport Information:DOT: PAINT, DOT: FLAMMABLE UN# 1263
===================== Regulatory Information =====================
SARA Title III Information:ALL INGREDIENTS ARE ON TSCA INVENTORY OR ARE
EXEMPT. (SARA, CERCLA, HAPS) TOXIC CHEMICAL SUBJECT TO REPORTING
REQUIRMENTS OF SARA AND CERCLA (40 CFR 302, 355, 372) OR HAPS (40
CFR 63)
State Regulatory Information:CALIFORNIA PROPOSITION 65: WARNING! THIS
PRODUCT CONTAINS A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO
CAUSE CANCER. # CALIF. TITLE 26: 22-12000 (PROP 65). WARNING!
THIS PRODUCT CONTAINS A CH EMICAL KNOWN TO THE STATE OF CALIFORNIA
TO CAUSE BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. 1) ALUMINO
SILICATE 2) XYLENE 3) EPOXY RESIN 4) MALAMINE FORMALDEHYDE RESIN
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|