===================== Product Identification =====================
MSDS NAME:11189, HYDROGEN PEROXIDE 30 - 50 %
NIIN:01-211-0958
Status Code:A
MSDS Number: CLFKR
=== Responsible Party ===
Company:FISHER SCIENTIFIC
Address:1 REAGENT LANE
City:FAIRLAWN
State:NJ
ZIP:07410
Country:US
Info Phone Num:201-796-7100
Emergency Phone Num:201-796-7100
Chemtrec Ind/Phone:(800)424-9300
CAGE:18464
=== Contractor Identification ===
Company:FISHER SCIENTIFIC
Address:1 REAGENT LANE
Box:City:FAIRLAWN
State:NJ
ZIP:07410
Country:US
Phone:201-796-7100
CAGE:18464
============= Composition/Information on Ingredients =============
Name:HYDROGEN PEROXIDE
CAS:7722-84-1
RTECS #:MX0899000
Minumum % Wt:30.
Maxumum % Wt:50.
OSHA PEL:1.4 MG/M3;1 PPM
ACGIH TLV:1.4 MG/M3;1 PPM
Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: BALANCE
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: CORROSIVE, CAUSES SEVERE BURNS,
& MAY CAUSE CORNEAL DAMAGE. SKIN: IRRITATION & POSSIBLE BURNS. MAY
CAUSE FORMATION OF PAPULES & VESICLES. INGESTION: CAUSES
GASTROINTESTINAL IRRITATION & BURNS. MAY CAUSE VASCULAR COLLAPSE &
DAMAGE, & BLEEDING OF THE STOMACH & ULCER FORMATION. MAY DAMAGE RED
BLOOD CELLS MAY CAUSE POSSIBLE CEREBRAL SWELLING & DEATH.
INHALATION:CAUSES CHEMICAL BURNS TO THE RE SPIRATORY TRACT. MAY
CAUSE ULCERATION OF NASAL TISSUE, CHEMICAL PNEUMONIA,
UNCONSCIOUSNESS, & DEATH. ACUTE LUNG DAMAGE & DELAYED PULMONARY
EDEMA AT HIGH CONCENTRATIONS. CHRONIC: DERMATITIS, MUTAGENIC
EFFECTS, OR CORNEAL DAMAGE.
Explanation of Carcinogenicity:ACGIH: A3 ANIMAL CARCINOGEN. IARC:
GROUP 3 CARCINOGEN (THE AGENT IS NOT CLASSIFIABLE AS TO ITS
CARCINOGENICITY TO HUMANS).
Effects of Overexposure:EYES: SEVERE BURNS. SKIN: MAY CAUSE
DISCOLORATION, ERTYHEMA, & SWELLING. INGESTION: CAUSES NAUSEA,
VOMITING & DIARRHEA. MAY CAUSE DIFFICULTY IN SWALLOWING, & STOMACH
DISTENSION. MAY RESULT IN IRRITA TION OF THE ESOPHAGUS.
INHALATION: MAY CAUSE INSOMNIA, NERVOUS TREMORS WITH NUMB
EXTREMITIES.
======================= First Aid Measures =======================
First Aid:GET IMMEDIATE MEDICAL AID FOR ALL ROUTES OF EXPOSURE. EYES:
DON'T ALLOW VICTIM TO RUB EYES. EXTENSIVE IRRIGATION (>30 MIN.)
REQUIRED. SKIN: IMMEDIATELY FLUSH WITH PLENTY OF SOAP & WATER (15
MIN. MINIM UM) WHILE REMOVING CONTAMINATED CLOTHING & SHOES.
INGESTION: DO NOT INDUCE VOMITING. IF VICTIM IS CONSCIOUS & ALERT,
GIVE 2-4 CUPFULS OF MILK OR WATER. NEVER GIVE ANYTHING BY MOUTH TO
AN UNCONSCIOUS P ERSON. WASH MOUTH OUT WITH WATER. INHALATION:
REMOVE FROM EXPOSURE. DO NOT GIVE MOUTH-TO-MOUTH RESPIRATION. GIVE
OXYGEN.
===================== Fire Fighting Measures =====================
Flash Point:NON-COMBUSTIBLE
Extinguishing Media:USE WATER ONLY! DO NOT USE CARBON DIOXIDE, OR DRY
CHEMICAL.
Fire Fighting Procedures:STRONG OXIDIZER. WEAR A SELF-CONTAINED
BREATHING APPARATUS IN PRESSURE-DEMAND, MSHA/NIOSH (APPROVED OR
EQUIVALENT), & FULL PROTECTIVE GEAR. DIKE & COLLECT WATER USED TO
FIGHT FIRE. USE WATER SPRAY T O KEEP FIRE-EXPOSED CONTAINERS COOL.
VAPORS CAN SPREAD ALONG THE GROUND & COLLECT IN LOW OR CONFINED
PLACES.
Unusual Fire/Explosion Hazard:CONTACT WITH COMBUSTIBLE MATERIALS MAY
CAUSE A FIRE. DURING A FIRE, IRRITATING & HIGH TOXIC GASES MAY BE
GENERATED. SOME OXIDIZERS MAY REACT EXPLOSIVELY WITH HYDROCARBONS
(FUEL). MAY DECOMPOSE EXPLOSI VELY WHEN HEATED OR INVOLVED IN A
FIRE. MAY ACCELERATE BURNING IF INVOLVED IN A FIRE.
================== Accidental Release Measures ==================
Spill Release Procedures:AVOID RUNOFF INTO WATERWAYS. CLEAN UP SPILLS
IMMEDIATELY. USE PROTECTIVE EQUIPMENT. USE WATER SPRAY TO DISPERSE
THE GAS/VAPOR. REMOVE IGNITION SOURCES. ABSORB SPILL USING AN
ABSORBENT, NON-COMBUSTIBLE MATERIAL. FLUSH SPILL AREA WITH WATER.
PROVIDE VENTILATION. DO NOT GET WATER INSIDE CONTAINERS. KEEP
COMBUSTIBLES AWAY FROM SPILL.
====================== Handling and Storage ======================
Handling and Storage Precautions:USE ONLY IN WELL VENTILATED AREAS.
CONTENTS MAY DEVELOP PRESSURE UPON STORAGE. KEEP CONTAINER TIGHTLY
CLOSED. AVOID CONTACT WITH COMBUSTIBLE MATERIALS. STORE PROTECTED
FROM LIGHT. KEEP AWAY FROM HEAT, SPARKS, & FLAME. STORE IN A COOL,
DRY, WELL-VENTILATED AREA AWAY FROM INCOMPATIBLE SUBSTANCES.
Other Precautions:UNUSED CHEMICALS SHOULD NOT BE RETURNED TO THE
CONTAINER. RINSE EMPTY DRUMS & CONTAINERS THOROUGHLY WITH WATER
BEFORE DISCARDING. KEEP AWAY FROM ALKALIES, OXIDIZABLE MATERIALS,
FINELY DIVIDED METALS, ALCOHOLS, & PERMANGANATE. STORE BELOW 35C.
STORE ONLY IN LIGHT-RESISTENT CONTAINERS FITTED WITH A SA FETY
VENT.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:A RESPIRATORY PROTECTION PROGRAM THAT MEETS
OSHA'S 29CFR1910.134 & ANSI Z88.2 REQUIREMENTS OR EUROPEAN STANDARD
EN 149 MUST BE FOLLOWED WHENEVER WORKPLACE CONDITIONS WARRANT A
RESPIRATOR'S USE.
Protective Gloves:WEAR APPROPRIATE PROTECTIVE GLOVES.
Eye Protection:WEAR APPROPRIATE PROTECTIVE EYEGLASSES OR CHEMICAL
SPLASH GOGGLES.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING. REMOVE
CONTAMINATED CLOTHING & WASH BEFORE REUSE. DO NOT GET IN EYES, ON
SKIN, OR ON CLOTHING. DO NOT INGEST OR INHALE. DISCARD CONTAMINATED
SHOES.
Supplemental Safety and Health
NONE
================== Physical/Chemical Properties ==================
HCC:D1
Boiling Pt:=108.C, 226.4F
B.P. Text:@ 760 MMHG
Melt/Freeze Pt:=-33.C, -27.4F
Decomp Temp:Decomp Text:NOT PROVIDED BY MFR
Vapor Pres:23 MM HG @ 30 DEG C
Vapor Density:1.10
Spec Gravity:1.1 - 1.2 (30 - 50%)
pH:3.3 (30% SOL)
Viscosity:1.25 CP
Evaporation Rate & Reference:1.0 (BUTYL ACETATE=1)
Solubility in Water:MISCIBLE
Appearance and Odor:LIQUID, CLEAR, COLORLESS, SLIGHT ACID ODOR.
Percent Volatiles by Volume:NOT PROVIDED
Corrosion Rate:NOT PROVIDED BY MFR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:NO
HEAVY METALS, REDUCING AGENTS, RUST, DIRT OR ORGANIC MATERIALS. STRONG
OXIDIZING AGENTS, STRONG REDUCING AGENTS.
Stability Condition to Avoid:DECOMPOSES SLOWLY TO RELEASE OXYGEN. AVOID
HEAT AND PH >4.
Hazardous Decomposition Products:OXYGEN, HYDROGEN, GAS, WATER, HEAT,
STEAM.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
=================== Toxicological Information ===================
Toxicological Information:EPIDEMIOLOGY, TERATOGENICITY, REPRODUCTIVE
EFFECTS, & NEUROTOXICITY: NO INFORMATION AVAILABLE. MUTAGENICITY:
CAS# 7722-84-1 MUTATION IN MICROORGANISMS: SALMONELLA TYPHIMURIUM =
100 UG/PLATE; HUMAN, E MBRYO = 50 UMOL/L; CYTOGENETIC ANALYSIS:
HUMAN, EMBRYO = 20 UMOL/L. MUTATION IN MAMMALIAN SOMATIC CELLS:
HAMSTER, LUNG = 1 MMOL/L.
===================== Ecological Information =====================
Ecological:RAIN WASHOUT IS EXPECTED DUE TO CONDENSATION OF HYDROGEN
PEROXIDE ON CONTACT WITH WATER DROPLETS. IN THE ATMOSPHERE,
INDIRECT PHOTOOXIDATION IS PERDICTED WITH A HALF-LIFE OF 10 TO 20
HOURS. NON-SIGNIF ICANT EVAPORATION & ADSORPTION FROM WATER
SURFACES & SOIL/SEDIMENTS IS EXPECTED. RAPID & CONSIDERABLE AEROBIC
BIODEGRADATION WAS DETERMINED WITH A HALF-LIFE 1 MINUTE (BIOLOGICAL
TREATMENT SLUDGE) & 0. 3 TO 2 DAYS (FRESH WATER). HYDROGEN PEROXID
IS NON-BIOACCUMULABLE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN A MANNER CONSISTENT WITH FEDERAL,
STATE, AND LOCAL REGULATIONS.
=================== MSDS Transport Information ===================
Transport Information:SHIPPING NAME: HYDROGEN PEROXIDE, AQUEOUS
SOLUTIONS 30%, HAZARD CLASS: 5.1, UN NUMBER: UN2014, PACKING GROUP
II.
===================== Regulatory Information =====================
SARA Title III Information:SECTION 302 (RQ) NONE OF THE CHEMICALS IN
THIS MATERIAL HAVE AN RQ. SECTION 302 (TPQ) CAS# 7722-84-1:
CONCENTRATION 52%; TPQ = 1000 POUNDS; RQ = 1000 POUNDS. SARA CODES
CAS#7722-84-1: ACUTE, FLAMMABLE . SECTION 313 NO CHEMICAL ARE
REPORTABLE UNDER SECTION 313.
Federal Regulatory Information:TSCA: CAS#7722-84-1 AND 7732-18-5 ARE
LISTED ON THE TSCA INVENTORY. CLEAN AIR ACT: THIS MATERIAL DOES NOT
CONTAIN ANY HAZARDOUR AIR POLLUTANTS, CLASS 1 OZONE DEPLETORS OR
CLASS 2 OZONE DEPLETORS. CLEA N WATER ACT: NOT LISTED. OSHA:
CAS#7722-84-1 IS CONSIDERED HIGHLY HAZARDOUS BY OSHA.
State Regulatory Information:HYDROGEN PEROXIDE CAN BE FOUND ON THE
FOLLOWING STATE RIGHT TO KNOW LISTS: CALIFORNIA, NEW JERSEY,
FLORIDA, PENNSYLVANIA, MINNESOTA, MASSACHUSETTS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|