Search   
MSDS  
:
 ABSORBED ELECTROLYTE BATTERY/DYNASTY; LEAD
CAS  
:
 7439-92-1
1309-60-0
7446-14-2
7664-93-9
NAME  
:
 lead
lead peroxide (lead dioxide), (osha pel from 29cfr
lead sulfate (osha pel from 29cfr 1910.1025)
sulfuric acid
=====================  Product Identification  =====================

MSDS NAME:ABSORBED ELECTROLYTE BATTERY/DYNASTY; LEAD
NIIN:01-089-1070
MSDS Number: BGLJT
=== Responsible Party ===
Company:JOHNSON CONTROLS INC GLOBE BATTERY DIV
Address:5757 N GREEN BAY AVE
Box:591
City:MILWAUKEE
State:WI
ZIP:53201
Country:US
Info Phone Num:414-228-3138
Emergency Phone Num:414-228-2746/800-424-9300(CHEMTREC)
CAGE:25244
=== Contractor Identification ===
Company:BATTERY OUTLET OF HAMPTON INC
Address:2815 GEORGE WASHINGTON HWY
Box:City:TABB
State:VA
ZIP:23602
Country:US
Phone:804-867-8280
CAGE:0FTM0
Company:JOHNSON CONTROLS INC GLOBE BATTERY DIV
Address:5757 N GREEN BAY AVE
Box:591
City:MILWAUKEE
State:WI
ZIP:53201
Country:US
Phone:800-365-7777
CAGE:25244
Company:PAN AM CORP
Address:PAN AM BUILDING, 200 PARK AVE
Box:City:NEW YORK
State:NY
ZIP:10166
Country:US
Phone:212-880-1234
CAGE:0K0T6

=============  Composition/Information on Ingredients  =============

Name:LEAD
CAS:7439-92-1
RTECS #:OF7525000
Fraction by Wt: 34%
Other REC Limits:0.1MG/M*3 (NIOSH)
OSHA PEL:0.05 MG/M3;1910.1025
ACGIH TLV:0.15 MG/M3; 8990
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Name:LEAD PEROXIDE (LEAD DIOXIDE), (OSHA PEL FROM 29CFR
    1910.1025)
CAS:1309-60-0
RTECS #:OG0700000
Fraction by Wt: 31%
Other REC Limits:0.1MG/M*2 (NIOSH)
OSHA PEL:0.05 MG/M3 (PB)
ACGIH TLV:0.15 MG/M3(PB); 8990

Name:LEAD SULFATE (OSHA PEL FROM 29CFR 1910.1025)
CAS:7446-14-2
RTECS #:OG4375000
Fraction by Wt: <1%
Other REC Limits:0.1MG/M*3 (NIOSH)
OSHA PEL:0.05 MG/M3 (PB)
ACGIH TLV:0.15 MG/M3 (PB);8990
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

Name:SULFURIC ACID
CAS:7664-93-9
RTECS #:WS5600000
Fraction by Wt: 34%
Other REC Limits:1MG/M*3 (NIOSH)
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3; 8990
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NOT SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:RESPIRATORY IRRITATION, SKIN
    IRRITATION, DERMATITIS, EYE IRRITATION, GASTROINTESTINAL UPSET.
    CHRONIC ANEMIA, DAMAGE TO KIDNEYS AND NERVOUS SYSTEM. LEAD MAY ALSO
    CAUSE REPRODUCTIVE SYSTEM DAMAGE AND CA N EFFECT DEVELOPING
    FETUSES. ELECTROLYTEMAY LEAD TO SCARRING OF CORNEA AND CHRONIC
    BRONCHITIS, EROSION OF TOOTH ENAMEL.
Explanation of Carcinogenicity:NO DEFINITIVE CAUSAL RELATIONSHIP HAS
    BEEN SHOWN BETWEEN SULFURIC MIST AND/OR LEAD AND CANCER IN HUMANS.
Effects of Overexposure:EYE/SKIN IRRITATION, DERMATITIS, LOSS OF
    APPETITE, DIARRHEA AND OR CONSTIPATION, CRAMPING, DIFFICULTY IN
    SLEEPING, FATIGUE, UPPER RESPIRATORY TRACT IRRITATION.
Medical Cond Aggravated by Exposure:INORGANIC LEAD AND ITS COMPOUNDS
    CAN AGGRAVATE CHRONIC FORMS OF KIDNEY, LIVER AND NEUROLOGIC
    DISEASES. CONTACT WITH ELECTROLYTE MAY AGGRAVAATE ECZEMA AND
    CONTACT DERMATITIS.

=======================  First Aid Measures  =======================

First Aid:INHLATION: REMOVE FROM EXPOSURE AND CONSULT A PHYSICIAN IF
    SYMPTOMS APPEAR. SKIN: WASH THOROUGHLY WITH SOAP AND WATER. IF
    ELECTROLYTE COMES INTO CONTACT WITH CLOTHING, REMOVE AND DISCARD.
    EYES: IMMEDI ATELY RINSE WITH COOL RUNNING WATER FORAT LEAST 15
    MINUTES. SEEK MEDICAL ATTENTION AFTER RINSING. INGESTION: DO NOT
    INDUCE VOMITING. REFER TO A PHYSICIAN IMMEDIATELY.

=====================  Fire Fighting Measures  =====================

Flash Point:-434F,-259C (H2)
Lower Limits:4.1 %
Upper Limits:74.2 %
Extinguishing Media:DRY CHEMICAL, FOAM OR CARBON DIOXIDE
Fire Fighting Procedures:USE POSITIVE PRESSURE, SELF-CONTIANED
    BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:HYDROGEN AND OXYGEN GASES ARE PRODUCED IN
    CELLS DURING NORMAL BATTERY OPERATION. THESE GASES ENTER AIR
    THROUGH VENT CAPS AND MAY CAUSE EXPLOSION.

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE COMBUSTIBLE MATERIALS AND ALL SOURCES
    OF IGNITION. COVER SPILL WITH SODA ASH (SODIUM BICARBONATE) OR
    QUICKLIME (CALCIUM OXIDE). MIX WELL. MAKE CERTAIN MIXTURE IS
    NEUTRAL THEN COLLECT. WEAR PROP ER PROTECTIVE GEAR.
Neutralizing Agent:SODA ASH (SODIUM BICARBONATE) OR QUICKLIME (CALCIUM
    OXIDE)

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT REMOVE VENT CAPS. TO AVOID
    DAMAGE TO TERMINALS AND SEALS, DO NOT DOUBLE-STACK INDUSTRIAL
    BATTERIES. NEVER RECHARGE IN UNVENTILATED SPACE.
Other Precautions:ELECTROLYTE IS ABSORBED BY INTERNAL BATTERY
    COMPONENTS. ACID SATURATED LEAD OXIDE IS A DARK REDDISH-BROWN TO
    GRAY SOLID WITH SLIGHT ACIDIC ODOR.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED UNDER NORMAL USE CONDITIONS.
    DURRING BATTERY FORMATION, ACID MIST CAN BE PRODUCED WHICH MAY
    CAUSE RESPIRATORY IRRITATION. IF SO, WEAR RESPIRATOR THAT IS
    SUITABLE FOR ACID MIST PROTECTION .
Ventilation:ROOM VENTILATION IS REQUIRED FOR BATTERIES UTILIZED FOR
    STANDBY POWER GENERATION.
Protective Gloves:VINYL COATED, PVC, GAUNTLET TYPE
Eye Protection:CHEMICAL SPLASH GOGGLES
Other Protective Equipment:SAFETY SHOES ARE RECOMMENDED. MAINTAIN
    EMERGENCY EYEWASH AND SHOWER.
Work Hygienic Practices:FOLLOWING CONTACT WITH INTERNAL BATTERY
    COMPONENTS, WASH HANDS THOROUGHLY BEFORE EATING, DRINKING OR
    SMOKING.
Supplemental Safety and Health
UNDER NORMAL CONDITIONS OF BATTERY USE, INTERNAL COMPONENTS WILL NOT
    PRESENT A HEALTH HAZARD. THE FOLLOWING INFORMATION IS PROVIDED FOR
    BATTERY ELECTROLYTE AND LEAD FOR EXPOSURE THAT MAY OCCUR DURING 
    BATTERY PRODUCTION OR CONTAINER BREAKAGEOR UNDER EXTREME HEAT
    CONDITIONS SUCH AS A FIRE.

==================  Physical/Chemical Properties  ==================

HCC:Z4
Boiling Pt:=110.C, 230.F
Melt/Freeze Pt:M.P/F.P Text:NOT GIVEN
Vapor Pres:11.7
Vapor Density:3.4
Spec Gravity:1.3
Evaporation Rate & Reference:NOT GIVEN
Solubility in Water:COMPLETE
Appearance and Odor:BATTERY ELECTROLYTE IS A CLEAR TO CLOUDY LIQUID
    ABSORBED BY INTERNAL BATTERY.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
MOSITURE, OXIDIZING OR REDUCING AGENTS
Stability Condition to Avoid:SPARKS, IGNITION SOURCES, HIGH
    TEMPERATURES. BATTERY ELECTROLYTE WILL REACT WITH WATER TO PRODUCE
    HIGH HEAT.
Hazardous Decomposition Products:OXIDES OF LEAD AND SULFUR, HYDROGEN,
    SULFUR DIOXIDE, SULFUR TRIOXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF ELECTROLYTE AS HAZARDOUS WASTE. DO
    NOT FLUSH LEAD CONTAMINATED ACID TO SEWER. SEND BATTERIES TO LEAD
    SMELTER FOR RECLAMATION FOLLOWING APPLICABLE FEDERAL, STATE AND
    LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
LUBRIPLATE 930-AA
EN ALKYD LUST QD BLUE 35109 78-83-1
108-88-3
14807-96-6
13463-67-7
14807-96-6
7439-92-1
110-19-0
744-508 78-83-1
8030-30-6
VARSOL 18 SOLVENT 95-63-6
108-88-3
100-41-4
MAGIN LENS CLEANING FLUID 67-63-0
75-28-5
74-98-6
80934,ITEK ELECTROSTATIC DISPRSNT,PC-38416
SP-1196 DYKEM SPRAY LAYOUT RED 123-86-4
64-17-5
71-36-3
90046-76-3
74-98-6
106-97-8
75-28-5
ARALDITE AV 1258 7429-90-5
1302-78-9
13463-67-7
14808-60-7
7727-43-7
10043-01-3
25068-38-6
HARDENER HV 1258 80-05-7
7429-90-5
112945-52-5
111-40-0
25154-52-3
1317-65-3
10043-01-3
HALON 1211,10 LB 353-59-3
7727-37-9
ZRC COLD GALVANIZING CMPD, 8281-10001/10004 7440-66-6
1314-13-2
8052-41-3
1330-20-7
ECK-40667 71-55-6
ECCO 1500 71-55-6
BOLT ROACH BAIT 2921-88-2
BOLT ROACH BAIT 2921-88-2
HALON 1211;BROMOCHLORODIFLUOROMETHANE; BCF 353-59-3
ABSORBED ELECTROLYTE BATTERY/DYNASTY; LEAD 7439-92-1
1309-60-0
7446-14-2
7664-93-9
LECTRA CLEAN,02018 71-55-6
127-18-4
124-38-9
P-702-1,HYDRAZINE DETECTOR PELLET
109-04 67-63-0
100-51-6
7732-18-5
EC-1981 78-93-3
108-10-1
DELTABOND 152 1344-28-1
2426-08-6
112945-52-5
25068-38-6
DELTA HARDENER A4
HIBICLENS 18472-51-0
67-63-0
7732-18-5
AUTO D2 OR R2D2 123-31-9
92-43-3
7757-83-7
1310-73-2
7647-15-6
ELECTROGRAPHIC DEVELOPER 8922-424.
GLYCOL ETHER DM 111-77-3
METHYL CARBITOL 111-77-3
MIL-I-85470/AS INHIBITOR,ICING FUEL SYSTEMS 111-77-3
METHYL CARBITOL 111-77-3
CAUSTIC POTASH 1310-58-3
T65 F 10,SHER-WOOD 600,WATER WHITE SEALER 108-88-3
110-19-0
78-93-3
67-63-0
O-F-499D TYPE B AMS 3410G FLUX AWS CL FB3A 12228-71-6
1310-58-3
7789-23-3
7732-18-5
MIL-I-51260,INSECTICIDE 300-76-5
1330-20-7
C-H-T DEGREASER;37-090-34 7783-20-2
37-090-34
FOAM BLOCK ASSEMBLY
FOAM BLOCK ASSEMBLY
EXXON HEAVY DUTY 10W 212038-02038 64742-54-7
64742-65-0
GR 10,MIL-L-2104D(MC-2878)(MC-1065) 7440-66-6
R SCRATCH REMOVER (77-9801-0711-2) 7732-18-5
7732-18-5
1310-58-3
1344-09-8
R SCRATCH REMOVER 8052-41-3
6834-92-0
1310-58-3
7732-18-5
32-4656, TONER REMOVER (ISSUED 6/2/83), 83-7-101013 110-49-6
71-55-6
32-4656,TONER REMOVER (ISSUED 6/2/83) 71-55-6
TONER REMOVER, 83-7-101013 110-49-6
71-55-6
340 HEAT SINK
188 8965,VNF1/RVNP COLOR DEVELOPER, PART A 1310-73-2
107-15-3
107-21-1
100-51-6
7647-15-6
7732-18-5
188 8742,VNF1/RVNP COLOR DEVELOPER,PART A-1 7732-18-5
188 8965 VNF-1/RVNP COLOR DEVELOPER REPLENISHER, PART B 7337-45-3
188 8742,VNF1/RVNP COLOR DEVELOPER, PART C 7601-54-9
7757-83-7

Free MSDS Search ( Providing 250,000+ Material Properties )