===================== Product Identification =====================
MSDS NAME:ZRC COLD GALVANIZING CMPD, 8281-10001/10004
NIIN:01-088-8751
MSDS Number: BGLJM
=== Responsible Party ===
Company:Z.R.CHEMICAL PRODUCTS CO.
Address:21 NEWPORT AVE
City:NORTH QUINCY
State:MA
ZIP:02171
Country:US
Info Phone Num:617-328-6700
Emergency Phone Num:800-424-9300(CHEMTREC)
CAGE:MO887
=== Contractor Identification ===
Company:Z R C CHEMICAL PRODUCTS CO
Address:21 NEWPORT AVE
Box:City:NORTH QUINCY
State:MA
ZIP:02171-2635
Country:US
CAGE:07957
Company:Z.R.CHEMICAL PRODUCTS CO.
Address:21 NEWPORT AVE
Box:City:NORTH QUINCY
State:MA
ZIP:02171
Country:US
Phone:617-328-6700
CAGE:MO887
============= Composition/Information on Ingredients =============
Name:ZINC (SARA III)
CAS:7440-66-6
RTECS #:ZG8600000
Fraction by Wt: 78.9%
OSHA PEL:10 MG/M3 (ZNO)
ACGIH TLV:10 MG/M3 (ZNO)
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:ZINC OXIDE
CAS:1314-13-2
RTECS #:ZH4810000
Fraction by Wt: 2%
OSHA PEL:15MG/M3 TDUST;5 FUME
ACGIH TLV:10MG/M3 TDUST
Name:STODDARD SOLVENT; (PETROLEUM DISTILLATES). VP:2 @ 20C.
LEL:0.8%.
CAS:8052-41-3
RTECS #:WJ8925000
Fraction by Wt: 12%
OSHA PEL:500 PPM
ACGIH TLV:100 PPM
Name:XYLENE. VP:6 @ 20C. LEL:1%.
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: 1.1%
OSHA PEL:100 PPM;150 STEL
ACGIH TLV:100 PPM;150 STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:SUPDAT:TO DIST IGNIT SOURCES & FLASH BACK. MOISTURE & ACID
CONTAM CAN RSLT IN HYDROGEN GAS EVOLUTION, CAUSING (ING 6)
RTECS #:9999999ZZ
Name:ING 5:CANS TO BULGE W/INCR PRESS. CANS SO DEFORMED SHOULD
NOT BE MOVED, OPENED/PUNCTURED. CALL (617)328-6700.
RTECS #:9999999ZZ
Name:HAZ DECOMP PROD:CARBON & NITROGEN WHEN HEATED TO
DECOMPOSITION.
RTECS #:9999999ZZ
Name:EFTS OF OVEREXP:REPORTS HAVE ASSOC RPTD & PRLNG OVEREXP TO
SOLVENTS W/PERMANENT DAMAGE TO BRAIN & CNS.
RTECS #:9999999ZZ
Name:SPILL PROC:DISP & USE ABSORB TO PICK UP RESIDUE. AVOID
DISCHARGING PAINT DIRECTLY INTO SEWER/SURF WATERS. DO NOT(ING 10)
RTECS #:9999999ZZ
Name:ING 9:FLUSH SPILLS W/WATER. USE NON-SPARKING TOOLS ONLY.
SPILLED MATL MAY BE SLIPPERY ON FLOORS.
RTECS #:9999999ZZ
Name:WASTE DISP METH:LANDFILLED ONLY AT APPROVED HAZARDOUS
DISPOSAL SITES USING APPROVED CONTRACTORS.
RTECS #:9999999ZZ
Name:OTHER PREC:INTERCONNECT & GROUND CNTNRS FOR TRANSFER OF
LIQS TO AVOID FIRES FROM STATIC SPKS. AREAS OF USE & (ING 13)
RTECS #:9999999ZZ
Name:ING 12:STOR FOR THIS MATL SHOULD HAVE GOOD VENT & ALL
SOURCES OF OPEN FLAME & HIGH HEAT SHOULD BE EXCLUDED. (ING 14)
RTECS #:9999999ZZ
Name:ING 13:PROHIBIT SMOKING IN THESE AREAS. ENSURE SUFFICIENT
VENT TO PVNT ACCUM OF HEAVY VAPS IN LOW LYING AREAS/ (ING 15)
RTECS #:9999999ZZ
Name:ING 14:SUMPS. DO NOT STORE >140F(40C). MATL IS ELEC
CONDUCTIVE. DO NOT APPLY BY ELECTROSTATIC SPRAY EQUIP, (ING 16)
RTECS #:9999999ZZ
Name:ING 15:UNLESS EQUIP IS MODIFIED FOR USE W/SUCH COATINGS BY
EQUIP MFR. DO NOT TAKE INTERNALLY. AVOID PRLNG CONT (ING 17)
RTECS #:9999999ZZ
Name:ING 16:W/SKIN. KEEP AWAY FROM CHILDREN. DO NOT PUNCTURE,
DRAG/SLIDE CNTNR. EMPTY CNTNRS MAY CNTN FLAMM RESIDUES (ING 18)
RTECS #:9999999ZZ
Name:ING 17:& EXPLODE IF HEATED WHEN SEALED.
RTECS #:9999999ZZ
Name:RESP PROT:FILTERS DESIGNED TO REMOVE COMBINATION OF
PARTICULATES & VAP. IN CONFINED AREAS USE NIOSH/MSHA APPRVD (ING
20)
RTECS #:9999999ZZ
Name:ING 19:AIR LINE TYPE RESPIRATORS OR HOODS.
RTECS #:9999999ZZ
Name:VENT:HEATING). EXHAUST LEVELS SHOULD BE MAINTAINED AT LEAST
100 LFM.
RTECS #:9999999ZZ
Name:HYGIENE PRACT: CONTAMINATED CLOTHING.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:SOLVS CNTND IN MIXTURE ARE CNS
DEPRESSANTS. SYMPS OF OVEREXP INCL DROW, DIZZ, HDCH, SLURRED
SPEECH, INTOX W/EUPHORIA &/OR DEPRESS LEADING TO STUPOR & UNCON.
NOSE & THROAT IRRIT MAY OCCUR FROM IN HAL. SKIN CONT MAY CAUSE
DEFAT & DERM. EYE CONT W/LIQ CAUSES TEARS, BURNING, IRRIT, CONJ.
INGEST WILL (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CAUSE POIS & MAY BE FATAL; AVOID ASPIR
IF INGESTED. DO NOT INDUCE VOMIT. LUNG CONT MAY CAUSE CHEM PNEUM.
DURING WELDING & BURNING OPERATIONS HAZ DECOMP PRODS MAY BE EVOLVED
FROM DRIED FILM, T HESE MAY INCL BUT NOT BE LTD TO ZINC OXIDES AS
WELL AS GASEOUS OXIDES OF CARBON & NITROGEN. CONSULT MD. CHRONIC:
(ING 8)
Medical Cond Aggravated by Exposure:RESPIRATORY CONDITIONS, DERMATITIS
& OTHER SKIN AFFLICTIONS. CONDITIONS OF CENTRAL NERVOUS SYSTEM.
======================= First Aid Measures =======================
First Aid:INH: MOVE TO FRESH AIR. RESTORE BRTHNG. KEEP QUIET/WARM, CALL
MD. EYES: IMMED FLUSH W/WATER AT LEAST 15 MIN, CALL MD. SKIN: WASH
W/MILD SOAP & WATER. DISCARD CONTAM CLOTHING, CALL MD. INGEST: DO
NOT I NDUCE VOMIT, CALL MD.
===================== Fire Fighting Measures =====================
Flash Point Method:SCC
Flash Point:104F,40C
Lower Limits:0.9
Upper Limits:7%
Extinguishing Media:ANY APPROVED CLASS FIRE EXINGUISHER, DRY CHEMICAL,
FOAM. DO NOT USE WATER.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . COOL CONTAINERS W/WATER.
Unusual Fire/Explosion Hazard:KEEP CNTNRS CLSD TIGHTLY. ISOLATE FROM
HEAT, ELEC EQUIP, SPKS & OPEN FLAME. ZINC PRESENT IN FINELY DIVIDED
FORM, IS HAZ WHEN ATOMIZED IN AIR & IF (SUPP DATA)
================== Accidental Release Measures ==================
Spill Release Procedures:FOR MASSIVE SPILLS, EVACUATE AREA. FOR ALL
SPILLS ELIM IGNIT SOURCES. DIKE & CONTAIN SPILLS W/DRY INERT MATLS
(SAND, EARTH, ETC). ELIM ALL SOURCES OF MOISTURE & DO NOT USE WATER
IN CLEAN UP OPERATIONS . RECOVER AS MUCH OF FREE LIQ AS POSS FOR
(ING 9)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN DRY AREAS AWAY FROM OXIDIZERS
(CHLORINE, OXYGEN), ALL ACIDS, ALKALIES & WATER. STORE LG QTYS ONLY
IN BLDGS IN COMPLIANCE W/OSHA 1910.105.
Other Precautions:THIS COMBUST LIQ SHOULD BE STORED IN COOL, CLEAN,
WELL VENTILATED, FIRE RESIST STOR ROOM/IN SOLV STOR CABINET THAT
MEETS OSHA REQUIREMENTS. STORE ONLY IN TOTALLY CLSD CANS
W/IDENTIFYING LBLS THAT INDI CATE FLAMMABILITY OF MATL. ELEC (ING
12)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IN OUTDOOR/OPEN AREAS W/UNRESTRICTED VENT, USE
NIOSH/MSHA APPRVD HIGH EFFICIENCY MECH RESP TO REMOVE PARTICLES OF
OVERSPRAY DURING SPRAY APPLICATION. IN AREAS OF RESTRICTED VENT,
USE NIOSH/MSHA APPRVD HIGH EFFICIENCY CHEM/MECH (ING 19)
Ventilation:WORK AREAS REQ EXHST VENT I/A/W OSHA 29 CFR 1910.1070 TO
MAINTAIN VAP LEVELS BELOW TLV (ESP DURING SPRAY, MIST/ (ING 21)
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORK GOGGS .
Other Protective Equipment:RUB APRON. PROT CREAMS, EYE WASH FOUNTAIN,
SAFETY SHOWER, CHEM RESIST BOOTS. EXPLO-PROOF VENT EQUIP,
NON-SPARKING TOOLS.
Work Hygienic Practices:OBSERVE ALL RULES OF GOOD HYGIENE DURING &
AFTER USE. WASH THORO BEFORE SMOKING/EATING. REMOVE & WASH/DISCARD
(ING 22)
Supplemental Safety and Health
EXPLO HAZ:SPKD, EXPLO IS POSS. CLSD CNTNRS MAY EXPLODE WHEN EXPOS TO
EXTREME HEAT. APPLICATION TO HOT SURFS REQS SPECIAL PRECS. DURING
EMER CNDTNS, OVEREXP TO DECOMP PRODS (GASEOUS OXIDES OF CARBON &
NITROGEN) MAY CAUSE HLTH HAZ. SYMPS MAYNOT BE IMMED APPARENT.
OBTAIN MED ATTN. HVR/AIR VAPS MAY FLOW ALONG SURFS(ING 5)
================== Physical/Chemical Properties ==================
HCC:F4
Boiling Pt:B.P. Text:>291F,>144C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:2.88 @ 77F
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:INSIGNIFICANT
Appearance and Odor:GREY LIQUID W/ODOR TYPICAL OF PETROLEUM
DISTILLATES.
Percent Volatiles by Volume:47
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
CAN REACT VIOLENTLY W/STRONG OXIDIZERS, WATER, ACIDS.
Stability Condition to Avoid:DUSTING & ACCUMULATION OF SPRAY RESIDUES.
Hazardous Decomposition Products:WATER & ALKALI CONT WILL PRDCE
HYDROGEN W/ADDNL RISK OF EXPLO & FIRE. MAY PRDCE FUMES OF ZINC
OXIDES & OXIDES OF (ING 7)
==================== Disposal Considerations ====================
Waste Disposal Methods:DISP OF ABSORBED MATL/FREE WASTE LIQ IN DRY
CNTNRS. DISP OF ALL MATLS INCL EMPTY CANS ACCORDING TO LOC, STATE &
FED REGS. DO NOT INCIN, DO NOT FLUSH TO SEWERS. CNTNRS MAY EXPLODE
IF HEATED EVEN WHEN E MPTY. IT IS REC THAT SOLID WASTE BE (ING 11)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|