===================== Product Identification =====================
MSDS NAME:TRA-BOND 2111 RESIN
NIIN:00-147-1585
Kit Part:Y
MSDS Number: BGWLC
=== Responsible Party ===
Company:TRA-CON INC.
Address:55 NORTH STREET
City:MEDFORD
State:MA
ZIP:02155
Info Phone Num:617-391-5550
Emergency Phone Num:617-391-5550
CAGE:KO274
=== Contractor Identification ===
Company:TRA-CON INC
Address:55 NORTH ST
Box:3933
City:MEDFORD
State:MA
ZIP:02155-4225
Country:US
Phone:617-391-5550
CAGE:22835
Company:TRA-CON INC.
Address:55 NORTH STREET
Box:City:MEDFORD
State:MA
ZIP:02155
Phone:617-391-5550
CAGE:KO274
============= Composition/Information on Ingredients =============
CAS:25068-38-6
RTECS #:SL6475000
Fraction by Wt: <100%
Name:N-BUTYL GLYCIDYL ETHER (BGE)
CAS:2426-08-6
RTECS #:TX4200000
Fraction by Wt: <20%
OSHA PEL:50 PPM
ACGIH TLV:25 PPM; 9293
Name:OTHER COMPONENTS (LESS THAN 0.1% EACH OR NON-HAZARDOUS)
Fraction by Wt: <10%
===================== Hazards Identification =====================
LD50 LC50 Mixture:ORAL RAT LD50 1200 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:REPEATED CONTACT OR BREATHING OF
VAPORS MAY CAUSE SEVERE IRRITATION. PRODUCT IS A STRONG SENSITIZER.
Explanation of Carcinogenicity:MFR REPORTS BUTYLGLYCIDYLETHER TO
POSSIBLY BE MUTAGENIC.
Effects of Overexposure:EYE/SKIN CONTACT:SEVERE
IRRITATION,SENSITIZATION.
Medical Cond Aggravated by Exposure:ALLERGIES,SENSITIZED REACTIONS.
======================= First Aid Measures =======================
First Aid:EYE:FLUSH WITH WATER 15 MIN. SKIN:WASH WITH SOAP & WATER.
INHALED:REMOVE TO FRESH AIR. GIVE ARTIFICIAL RESPIRATION OR OXYGEN
AS NEEDED. INGESTED:GIVE WATER,THEN INDUCE VOMITING,IF LARGE AMOUNT
IS SWAL LOWED. GET IMMEDIATE MEDICAL ATTENTION.IF ANY SYMPTOMS
PERSIST OR ARE SEVERE,GET PROMPT MEDICAL CARE.
===================== Fire Fighting Measures =====================
Flash Point Method:SCC
Flash Point:164F/74C
Extinguishing Media:CARBON DIOXIDE,DRY CHEMICAL,WATER FOG OR SPRAY.
Fire Fighting Procedures:WEAR SELF CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:NONE
================== Accidental Release Measures ==================
Spill Release Procedures:WIPE UP WITH PAPER OR CLOTH. PREVENT SKIN/EYE
CONTACT. CLEAN WITH SOLVENT,BEING AWARE OF FLAMMABILITY. DETERGENT
MAY ALSO BE USED.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A COOL,DRY,WELL VENTILATED
AREA. KEEP TIGHTLY CLOSED.
Other Precautions:DURING USE,BE AWARE OF HEALTH HAZARDS OF THE SPECIFIC
HARDENER BEING USED.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR EQUIPPED WITH
CARTRIDGE FOR ORGANIC VAPORS/MISTS OR SUPPLIED AIR RESPIRATOR IF
EXPOSED ABOVE TLV/PEL,ESPECIALLY IF USED IN CONFINED AREAS.
Ventilation:USE NORMAL ROOM VENTILATION. LOCAL EXHAUST MAY BE NECESSARY
TO KEEP EXPOSURE BELOW PEL/TLV.
Protective Gloves:RUBBER OR DISPOSABLE PLASTIC.
Eye Protection:SAFETY GLASSES OR SPLASH GOGGLES.
Other Protective Equipment:EYE WASH SAFETY SHOWER. CLOTHING AS NEEDED
TO PREVENT SKIN CONTACT.
Work Hygienic Practices:USE STRICT CHEMICAL HYGIENE PRACTICE. AVOID ANY
POSSIBLE CONTACT.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
HCC:V4
Boiling Pt:B.P. Text:>350F/177C
Vapor Pres:<1 MM
Vapor Density:>1
Spec Gravity:1.25
Evaporation Rate & Reference:LOW
Solubility in Water:LOW
Appearance and Odor:TRANSLUCENT,MEDIUM VISCOSITY LIQUID;SLIGHT SWEET
ODOR.
Percent Volatiles by Volume:<0.2
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
PHENOL,ALDEHYDES,ACIDS,CARBON MONOXIDE,STRONG OXIDIZERS.
Stability Condition to Avoid:HEAT,UNCONTROLLED REACTION WITH AMINES.
Hazardous Decomposition Products:CARBON MONOXIDE,CARBON DIOXIDE.
Conditions to Avoid Polymerization:MFR LISTS HIGH TEMPERATURES,STRONG
ACIDS,METALLIC SALTS,CERTAIN ORGANICS WHICH APPEAR TO CAUSE
UNDESIRED POLYMERIZATION.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE I/A/W FEDERAL,STATE,LOCAL REGULATIONS.
MFR SUGGESTS INCINERATION, LANDFILL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|