MATERIAL SAFETY DATA SHEET
SECTION 1: CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
PRODUCT: QA-600 Adhesive (Part B) November 23, 2005
Vishay Micro-Measurements MSDS # MGM084A
Post Office Box 27777
Raleigh, NC 27611
919-365-3800
CHEMTREC 1-800-424-9300 (U.S.)
703-527-3887 (Outside U.S.)
NOTE: CHEMTREC numbers to be used only in the event of chemical emergencies involving a spill, leak, fire,
exposure or accident involving chemicals.
SECTION 2: HAZARDOUS INGREDIENTS / IDENTITY INFORMATION
CAS NUMBER CHEMICAL IDENTITY %
109-99-9 Tetrahydrofuran 77.8
552-30-7 Trimellitic Anhydride 22.2
SECTION 3: HEALTH HAZARD DATA
Routes of Entry:
Inhalation: YES Skin: YES Ingestion: Accidental
Health Hazards (Acute and Chronic): Repeated or high exposure may cause kidney and/or liver damage; affect
the lungs. Repeated skin exposure can cause dryness, cracking of skin and rash.
Carcinogenicity: NTP: Not listed
IARC Monographs: Not listed
OSHA Regulated: Not listed
DOCUMENT NO.: 14078 805-FRM011
QA-600 Adhesive (Part B) MSDS # MGM084A
Signs and Symptoms of Exposure:
INHALATION: Causes irritation to the respiratory tract. Symptoms may include coughing, shortness of breath.
Tetrahydrofuran is an anesthetic agent in high concentrations. Overexposure may cause dizziness, headache,
nausea and possible fluid in the lungs. May cause liver, kidney or lung injury.
EYE CONTACT: Causes irritation, redness, and pain. Contact may cause permanent eye damage.
SKIN CONTACT: Causes irritation to skin. Symptoms include redness, itching, and pain.
INGESTION: Causes irritation to gastrointestinal tract. Symptoms may include nausea, vomiting and diarrhea.
May cause sore throat and abdominal pain. May cause liver or kidney injury.
Medical Conditions Generally Aggravated by Exposure: Persons with pre-existing skin disorders or eye
problems or impaired liver or kidney function may be more susceptible to the effects of the substance.
SECTION 4: EMERGENCY AND FIRST AID PROCEDURES
INHALATION: If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give
oxygen. Get medical attention immediately.
EYE CONTACT: In case of eye contact, immediately flush eyes with plenty of water for at least 15 minutes while
holding eyelids open. Get medical attention.
SKIN CONTACT: Immediately flush skin with plenty of water for at least 15 minutes. Remove contaminated
clothing. Wash affected area with soap and water. Launder contaminated clothing before reuse. Get medical
attention.
INGESTION: Call a physician. If swallowed, induce vomiting only as directed by a physician. Never give anything
by mouth to an unconscious person. If vomiting occurs, keep head below hips to prevent aspiration into lungs.
SECTION 5: FIRE AND EXPLOSION HAZARD DATA
Flash Point (Method Used): 6掳F (-14掳C) CC (For Tetrahydrofuran)
Autoignition Temperature: 610掳F (321掳C) (For Tetrahydrofuran)
Flammable limits: LEL: 20. UEL: 11.8 (For Tetrahydrofuran)
Extinguishing Media: Dry chemical or carbon dioxide. Water spray may be used to keep fire-exposed containers
cool.
Special Firefighting Procedures: Firefighters should wear proper protective equipment and self-contained
breathing apparatus with full facepiece operated in positive pressure mode. Water may be used to flush spills away
from exposures and to dilute spills to non-flammable mixtures.
2
DOCUMENT NO.: 14078 805-FRM011
QA-600 Adhesive (Part B) MSDS # MGM084A
Unusual Fire and Explosion Hazards: Vapors may flow along surfaces to distant ignition source and flash back.
Closed containers exposed to heat may explode. May form explosive organic peroxides when exposed to air or
light or with age.
SECTION 6: ACCIDENTAL RELEASE MEASURES
Steps to be taken if material is released or spilled: Keep unnecessary people away; isolate hazard area. Wear
self-contained breathing apparatus and full protective clothing. Shut off ignition sources; no flares, smoking or
flames in area. Stop leak if you can do so without risk. Keep out of storm drains, surface waters and soil. Use
water spray to reduce vapors. Take up with sand or other non-combustible absorbent material and place into
container for later disposal. Flush area with water.
SECTION 7: EXPOSURE CONTROLS -- PERSONAL PROTECTION
Respiratory Protection: If the exposure limit is exceeded, a half-face organic vapor respirator may be worn for up
to 10 times the exposure limit or the maximum use concentration specified by the appropriate regulatory agency or
respirator supplier, whichever is lowest. A full-facepiece organic vapor respirator may be worn up to 50 times the
exposure limit or the maximum use concentration specified by the appropriate regulatory agency or respirator
supplier, whichever is lowest. For emergencies or instances where the exposure levels are not known, use a full-
facepiece positive-pressure, air-supplied respirator. WARNING: Air-purifying respirators do not protect workers in
oxygen-deficient atmospheres.
Ventilation: A system of local and/or general exhaust is recommended to keep employee exposure below the
Airborne Exposure Limits. Local exhaust ventilation is generally preferred because it can control the emissions of
the contaminant at its source, preventing dispersion of contaminant into the general work area.
Protective Gloves: Rubber or neoprene gloves are recommended.
Eye Protection: Chemical splash goggles and/or a full faceshield where splashing is possible is recommended.
Other Protective Clothing or Equipment: Impervious over-clothing as needed to prevent skin contact. Safety
shower and eye wash station in local area.
Work / Hygienic Practices: Wash thoroughly after using.
SECTION 8: HANDLING AND STORAGE
Precautions to be taken in handling and storing: Keep containers tightly closed. Store in a cool, dry, well-
ventilated, flammable liquid storage area. Take precautionary measures against static discharges. Keep away
from open flames and spark producing equipment. Keep product out of light.
Other Precautions: Keep containers tightly sealed when not in use. Bond and ground containers when
transferring liquid. Use caution when opening cap. Avoid prolonged exposure to vapors and skin contact. Avoid
breathing vapors.
3
DOCUMENT NO.: 14078 805-FRM011
QA-600 Adhesive (Part B) MSDS # MGM084A
SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES
Boiling Point: 1510掳F (66掳C) *
Vapor Pressure (mmHg): 129 @ 68掳F (20掳C) *
Vapor Density (Air = 1): 2.4 *
Specific Gravity (H2O = 1): 0.9
Melting Point: N/A
Evaporation Rate (BuAc = 1): 8.0 *
Volatile Organic Compounds: 77.8 %
Solubility in Water: Appreciable (more than 50%)
Appearance and Odor: Colorless to light amber liquid; ether-like odor.
*Based on Tetrahydrofuran
SECTION 10: STABILITY AND REACTIVITY DATA
Stability: Stable in closed containers with oxygen and light excluded. Distillation or evaporation can concentrate
peroxides (if present) to create an explosion hazard.
Conditions to Avoid: Heat, flame, other sources of ignition, light, air.
Incompatibility (Materials to Avoid): Acids, strong oxidizing agents, strong bases, strong reducing agents.
Hazardous Decomposition or By-products: Carbon dioxide and carbon monoxide may form when heated to
decomposition. May also release toxic and irritating vapors.
Hazardous Polymerization: May occur.
SECTION 11: TOXICOLOGICAL INFORMATION
Tetrahydrofuran
OSHA PEL: 200 ppm (TWA)
ACGIH TLV: 200 ppm (TWA)
OTHER: 250 PPM (STEL)
LD50 IPR (RAT) 2900 mg/kg
LD50 INHAL (RAT) 78 g/m3
Trimellitic Anhydride
OSHA PEL: Not listed
ACGIH TLV: Not listed
Other: NIOSH REL 0.04 mg/m3
LD50 ORAL (RAT) >2730 mg/kg
LD50 DERMAL (RABBIT) >23000 mg/kg
LD50 INHALATION >2330 mg/m3 (8 Hours)
4
DOCUMENT NO.: 14078 805-FRM011
QA-600 Adhesive (Part B) MSDS # MGM084A
SECTION 12: DISPOSAL CONSIDERATIONS
Waste Disposal Method: Do not dump into any sewers, on the ground, or into any body of water. All disposal
methods must be in accordance with all local, state and federal environmental regulations. Regulations may vary in
different locations. Waste characterizations and compliance with applicable laws are the responsibility of the waste
generator.
SECTION 13: TRANSPORTATION INFORMATION
SHIPPING NAME CLASS PACKING GROUP UN NUMBER
Tetrahydrofuran, 3 II 2056
Flammable Liquid
SECTION 14: REGULATORY INFORMATION
SECTION 313 SUPPLIER NOTIFICATION:
This product contains a toxic chemical or chemicals (as listed below) subject to the reporting requirements of
Section 313 Title III of the Superfund Amendment and Reauthorization Act of 1986 and 40 CFR Part 372.
CAS NUMBER CHEMICAL NAME % BY WEIGHT
None listed.
TSCA NOTIFICATION:
All components of this product are listed in the Toxic Substance Control Act Chemical Substance Inventory (TSCA).
SECTION 15: OTHER INFORMATION
To the best of our knowledge, the information provided above meets the requirements of the United States
Occupational Safety and Health Act and regulations established under 29 CFR 1910.1200 (g)(2)(c)(1)-(4) for a
mixture of hazardous chemicals which has not been tested as a whole. The data provided on this Material Safety
Data Sheet is from manufacturers of the original components. Vishay Micro-Measurements specifically disclaims
any and all form of liability and/or responsibility for the application of this product.
5
DOCUMENT NO.: 14078 805-FRM011
|