# 12015
llaterial
Safety
DataSheet
c o M M o N N A - E. ,
M
VespheneII
sYNOt{fMs
AqueousPhenolicGermicidalDetergent
tlae: Bla* s6 ae nd pflniW. lf ary iterrb m M q
rc hbmatin isadffi, tle W mg ttemar@ b iiWe ilEf
SectionI
Marutaclun/ Prsard
rareptvrrtunbagoo-424-9300
CalgonVestalLaboratories Nwrserrahrrsir
5035ManchesterAvenue 314-535- 1g 10
Saint
Louis,MO 63110 April9, 1991
ftcpc鈧瑀{odbn4
Soction ll . Hazardouelngredicnte/ tdentity tntormation
Fhzadoua Conpon$ts (Spocifc Chofi*al lde.rfiy)
ACGIHTLV gqopaionaf'
Odrclinrit*Reconnpnded
2-Phenylphenol <10
cAs # 9043-7
O-Benzyl-P-Chlorophenol
cAs #120-32-1
SodiumP-TertiaryAmylphenate
cAs # 8046-6
HexyleneGlycol 25ppm 25 ppm <5
cAs # t07-4t-5
Isopropanol 400ppm 400ppm
cAs # 67-$-A
9elion tll . Fhyeicat/ Ch鈧琺icalCharacterb$cs
1.035 25"C
@
V4or Prccsura
(nm Hgj
Unk
Vapor Dansity (AlR - 1)
Soldility in Wabr
complete
Am鈧琣fanca and Odor
amberliquid;mild,
SectionlV - Fire and Haard Data NFPA Ra
EniBubhing M6dia
water;carbondioxide;foam;dry chemical
proc鈧琩ue
Spcid Ffu鈧?
Figt(ing
wear a self-contained
brea*ringapparatus
andprotective
clothing.
Unus'/alFio and 6alo6bn Hazards
na
,:l
{--.-it l" i *".. .\
E4lc &wiatca, Inc, 1991
NFPA Bating: 0
Conditionslo AvoiJ
Polfrumdion
NFPA Rating:3 -
Section-' - tlealth HazardData
Section Vt'tlealth Hazaro uala Ing6tion?
*-"-" Vl skjn? ]鈧琒
Hffi;t;;-
tnnaaon' Yes
y,
iiil!(") otEnt !0S
eYesi SKmi feSPUatuV Df
rdsetorsans:
Hshh Haards (Acutosd UhronEl
t\* ' ^ n?j['*::Y:?li:"tTi:g#fi g h |--v i r r i irit io** o toe e ymouth, l a t i o n o i
^,. : l ' . + . ; "rvrs'v'r nru vr^D'--./ l
nlrrfin ic's'l ta net th eS.tnha
is corrosive the eyesand
ano sKrrl' t-''uuts(r '
Concenffate corrosive to the.eves
to the mouth, throat
is fttating to the throat
concenffate is exEemelyln
Ingestionof concenuate
passages.
i"i""t"'uradder timorswhen at
fed
mistsmay be initating to nasal J;;"
*'of;iyiiuiJ;r";; *" """tu"'"#ffHltil;r
sodiuri o-phe-nygh"nur"
stomach.
and rn'iTtitr?'fii'"1T]*H*,f
,","r"r.
doses
exaggerated lfi*i"
""*"rr., lAFKiMonosrar.sf
Yes
fri-riffiF--
Carch鈧偓nictY
MediralOoflditbns.. -
Gen鈧瑀allyAggtavated bY ElFcuF
Unk
immediatelY
Ml'Precautiorrs tor SafeHrnctlilg anc!!1
Secrion
orsfillod
is Faleased
t" cGndeid
;ffi1"k""
Spitttmaybe cleaned with flowing water'
up
-fr:H?ilffirardous manufacrurer.
of consulr
Management
waste
u a" t"xun in Handting Storing
performance
atd
F["",,ti*"
occasional
*ill;;il;lno.*
rhisproduct ry9itit1*:-11i***ll:i:J:n'normal
Yv
w ur
b"in*u'"d.
pIUuuvL
I lllJ
u*io,"dbbfo."
rhu*.dund
i,;;;;;li;Gr'rn
;#Jr;;;;;;:
O$sr P6cautpng
Readand observethe labeled useinstructions'
Section Vlll . Control l/leasures
Respiratqy Protac'tion(Sp鈧琧ify Typ6)
normalroomventilation
Ey"Prddi*
safet
Proteclivaclovss
fUbbgf
Other Protec'tivaClothing or Equprerd
|