Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

110-54-3

File Name: cannoninstrument_com---cannon_msds_cii07-007_general_purpose_visc_std_n-4_hexanes.asp
           Product Name: General Purpose Viscosity
Standard � N.4
Revision Date: March 26, 2007

Page 1 of 12
MSDS ref CII07-007

MATERIAL SAFETY DATA SHEET
SECTION 1 PRODUCT AND COMPANY IDENTIFICATION

PRODUCT
General Purpose Viscosity Standard � N.4
Product name:
Product description: Petroleum hydrocarbon liquid; hexanes/ normal hexane
Product code: 9727-C10
Intended use: Low viscosity calibration standard

COMPANY IDENTIFICATION
Supplier: Cannon Instrument Company
2139 High Tech Road
State College, Pennsylvania 16803
Product Technical Information: (814) 353-8000
Product MSDS Information: (814) 353-8000

EMERGENCY TELEPHONE NUMBER:
24-Hour Transportation Emergency: (800) 255-3924 Domestic CHEM-TEL Inc.
24-Hour Health Emergency: +1 (813) 248-0585 Overseas CHEM-TEL Inc. (please call collect)

SECTION 2 COMPOSITION/INFORMATION ON INGREDIENTS

OSHA Hazardous Substance(s) or Complex Substance(s)

This product is hazardous as defined in 29 CFR1910.1200, based on the following:
INGREDIENTS CAS Number Wt % EINECS SYM R-Phrases
R11, R62, R65, R48/20,
n-Hexane 110-54-3 95% 203-777-6 F, Xn, N
R38, R67, R51/53
Related materials Various < 5% NA NA NA

Occupational Exposure Limits:
Component Limit TWA STEL Ceiling / Peak Notation
n-Hexane ACGIH 50 ppm NA NA Skin
n-Hexane German MAK 1800 mg/m3 NA 4 NA
n-Hexane OSHA PEL 500 ppm NA NA NA

Note: State, local or other governments/ agencies may have established more stringent
guidelines. Consult regulatory agencies or seek expert advice for additional standards/
recommendations
SECTION 3 HAZARD IDENTIFICATION

This material is considered hazardous according to regulatory guidelines (See Section 15).


This information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. The information
and recommendations contained herein is compiled from suppliers� MSDS and are accurate and reliable to the best of Cannon Instrument Company’s knowledge and belief as of the
indicated revision date. No representation, warranty or guarantee, however, is made with regards to accuracy, reliability or completeness. Conditions of use of the material are under
the control of the user; therefore, it is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use.
Product Name: General Purpose Viscosity
Standard � N.4
Revision Date: March 26, 2007

Page 2 of 12
MSDS ref CII07-007

POTENTIAL PHYSICAL/CHEMICAL EFFECTS:
Extremely flammable liquid and vapor. Vapor can cause flash fire. Keep away from heat, sparks, flames,
static electricity or other sources of ignition. Use explosion-proof pumps and/ or other electrical
equipment as required. Static accumulation hazard: Bond/ ground equipment containers during transfer
operations

POTENTIAL HEALTH EFFECTS:
Overexposure to n-hexane may cause effects on the peripheral nerves, resulting in weakness or
numbness of lower limbs. Prolonged overexposure may result in damage to the central
nervous system. Narcotic effects occur at levels above the PEL/ TLV. Prolonged repeated skin contact
with low viscosity materials may defat the skin resulting in possible irritation and dermatitis. Eye
irritation. Skin irritation. Respiratory irritation, dizziness, nausea, loss of consciousness. Toxic effects or
illness can result from absorption through skin. Aspiration hazard: If ingested, liquid can be aspirated
into the lungs, resulting in chemical pneumonitis and severe lung irritation, potentially resulting in death.
DO NOT INDUCE VOMITING.

Eye: Eye irritant. Contact may cause stinging, watering, redness, and swelling.
Skin: Skin irritant. Contact may cause redness, itching, burning, and skin damage. Prolonged or
repeated contact can worsen irritation by causing drying and cracking of the skin, leading to
dermatitis (inflammation). Contact may result in skin absorption but symptoms of toxicity are not
anticipated by this route alone under normal conditions of use.
Inhalation (Breathing): Low degree of toxicity by inhalation.
Other Comments: Reports have associated repeated and prolonged occupational overexposure
to solvents with permanent brain and nervous system damage (sometimes referred to as Solvent
or Painters' Syndrome). Intentional misuse by deliberately concentrating and inhaling this material
may be harmful or fatal.
Ingestion (Swallowing): Low degree of toxicity by ingestion. ASPIRATION HAZARD - This material can
enter lungs during swallowing or vomiting and cause lung inflammation and damage. DO NOT
INDUCE VOMITING.
Signs and Symptoms: Effects of overexposure may include irritation of the nose and throat,
irritation of the digestive tract, headaches, nausea, transient excitation followed by signs of
nervous system depression (e.g., headache, drowsiness, dizziness, loss of coordination,
disorientation and fatigue).
Cancer: Not classified as carcinogenic
Target Organs: Overexposure may cause injury to the peripheral nervous system. There is limited
evidence from animal studies that overexposure may cause injury to the male reproductive
system.
Pre-Existing Medical Conditions: Conditions aggravated by exposure may include skin disorders,
respiratory (asthma-like) disorders. Exposure to high concentrations of this material may increase the
sensitivity of the heart to certain drugs. Persons with pre-existing heart disorders may be more
susceptible to this effect (see Section 4 - Note to Physicians).

POTENTIAL ENVIRONMENTAL EFFECTS:
Specific data/ information has not been provided by suppliers

NFPA HAZARD ID: Health: 1 Flammability: 3 Reactivity: 0
(National Fire Protection Association)

HMIS HAZARD ID: Health: 2* Flammability: 3 Reactivity: 0

This information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. The information
and recommendations contained herein is compiled from suppliers� MSDS and are accurate and reliable to the best of Cannon Instrument Company’s knowledge and belief as of the
indicated revision date. No representation, warranty or guarantee, however, is made with regards to accuracy, reliability or completeness. Conditions of use of the material are under
the control of the user; therefore, it is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use.
Product Name: General Purpose Viscosity
Standard � N.4
Revision Date: March 26, 2007

Page 3 of 12
MSDS ref CII07-007

*Possible chronic effects

NOTE: This material should not be used for any other purpose than the intended use in Section 1 without expert
advice.

SECTION 4 FIRST AID MEASURES

INHALATION: If respiratory symptoms develop, move victim away from source of exposure and into fresh air. If
symptoms persist, seek medical attention. If victim is not breathing, clear airway and immediately begin
artificial respiration. If breathing difficulties develop, oxygen should be administered by qualified
personnel. Seek immediate medical attention.

SKIN CONTACT: Remove contaminated shoes and clothing, and flush affected area(s) with large amounts of
water. If skin surface is damaged, apply a clean dressing and seek medical attention. If skin surface is not
damaged, cleanse affected area(s) thoroughly by washing with mild soap and water. If irritation or
redness develops, seek medical attention.

EYE CONTACT: Move victim away from exposure and into fresh air. If irritation or redness develops, flush eyes
with clean water and seek medical attention. For direct contact, hold eyelids apart and flush the affected
eye(s) with clean water for at least 15 minutes. Seek medical attention.

INGESTION: Aspiration hazard: Do not induce vomiting or give anything by mouth because this material can
enter the lungs and cause severe lung damage. If victim is drowsy or unconscious and vomiting, place on
the left side with the head down. If possible, do not leave victim unattended and observe closely for
adequacy of breathing. Seek medical attention.

NOTE TO PHYSICIAN: Epinephrine and other sympathomimetic drugs may initiate cardiac arrhythmias in
persons exposed to high concentrations of hydrocarbon solvents (e.g., in enclosed spaces or with
deliberate abuse). The use of other drugs with less arrhythmogenic potential should be considered. If
sympathomimetic drugs are administered, observe for the development of cardiac arrhythmias.

Material, if aspirated into the lungs, may cause chemical pneumonitis. Treat appropriately.

PRE-EXISTING MEDICAL CONDITIONS WHICH MAY BE AGGRAVATED BY EXPOSURE
None identified by the suppliers

SECTION 5 FIRE-FIGHTING MEASURES

EXTINGUISHING MEDIA

Appropriate extinguishing media: Dry chemical, carbon dioxide, or foam is recommended. Water spray is
recommended to cool or protect exposed materials or structures. Carbon dioxide can displace oxygen. Use caution
when applying carbon dioxide in confined spaces.
Inappropriate extinguishing media: Water may be ineffective for extinguishment, unless used under favorable
conditions by experienced fire fighters.

FIRE FIGHTING
Fire fighting instructions: For fires beyond the incipient stage, emergency responders in the immediate hazard area
should wear bunker gear. When the potential chemical hazard is unknown, in enclosed or confined spaces, or when

This information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. The information
and recommendations contained herein is compiled from suppliers� MSDS and are accurate and reliable to the best of Cannon Instrument Company’s knowledge and belief as of the
indicated revision date. No representation, warranty or guarantee, however, is made with regards to accuracy, reliability or completeness. Conditions of use of the material are under
the control of the user; therefore, it is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use.
Product Name: General Purpose Viscosity
Standard � N.4
Revision Date: March 26, 2007

Page 4 of 12
MSDS ref CII07-007
explicitly required by DOT, a self contained breathing apparatus should be worn. In addition, wear other appropriate
protective equipment as conditions warrant (see Section 8).

Isolate immediate hazard area, keep unauthorized personnel out. Move undamaged containers from immediate
hazard area if it can be done with minimal risk. Water spray may be useful in minimizing or dispersing vapors and to
protect personnel. Cool equipment exposed to fire with water, if it can be done with minimal risk. Avoid spreading
burning liquid with water used for cooling purposes.

Unusual fire hazards: This material is extremely flammable and can be ignited by heat, sparks, flames, or other sources of
ignition (e.g., static electricity, pilot lights, mechanical/electrical equipment, and electronic devices such as cell
phones, computers, calculators, and pagers which have not been certified as intrinsically safe). Vapors may travel
considerable distances to a source of ignition where they can ignite, flash back, or explode. May create vapor/air
explosion hazard indoors, in confined spaces, outdoors, or in sewers. Vapors are heavier than air and can
accumulate in low areas. If container is not properly cooled, it can rupture in the heat of a fire.

Hazardous combustion products:
Carbon monoxide. carbon dioxide.

FLAMMABILITY PROPERTIES
OSHA Flammability Class: Flammable Liquid
NFPA Flammability Class: 1B Flammable Liquid
NFPA RATINGS: Health: 1 Flammability: 3 Reactivity: 0
Flash point °C (°F) [method]: -23°C ( -9.4°F) [TCC, ASTM D-56]
Flammable limits (approx. Volume % in air) � LEL: UEL: 7.7
1.1
Autoignition temperature °C (°F): 225°C / 437°F

SECTION 6 ACCIDENTAL RELEASE MEASURES

NOTIFICATION PROCEDURES
Notify fire authorities and appropriate federal, state, and local agencies. Immediate cleanup of any spill is
recommended. If spill of any amount is made into or upon navigable waters, the contiguous zones, or adjoining
shorelines, notify the National Response Center (phone number 800-424-8802).

PROTECTIVE MEASURES
Extremely flammable. Keep all sources of ignition and hot metal surfaces away from spill/release. The use of
explosion-proof electrical equipment is recommended. Stay upwind and away from spill/release. Notify persons down
wind of the spill/release, isolate immediate hazard area and keep unauthorized personnel out. Stop spill/release if it
can be done with minimal risk. Wear appropriate protective equipment including respiratory protection as conditions
warrant (see Section 8).

SPILL MANAGEMENT
Land/ water spill: Prevent spilled material from entering sewers, storm drains, other unauthorized drainage
systems, and natural waterways. Dike far ahead of spill for later recovery or disposal. Use foam on spills
to minimize vapors (see Section 5). Spilled material may be absorbed into an appropriate absorbent
material.

Water spill and land spill management recommendations are based on the most likely spill scenario for
this material; however, geographic conditions, wind, temperature, (and in the case of a water spill) wave
and current direction and speed may greatly influence the appropriate action to be taken. For this reason,
local experts should be consulted. Note: Local regulations may prescribe or limit action to be taken.


This information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. The information
and recommendations contained herein is compiled from suppliers� MSDS and are accurate and reliable to the best of Cannon Instrument Company’s knowledge and belief as of the
indicated revision date. No representation, warranty or guarantee, however, is made with regards to accuracy, reliability or completeness. Conditions of use of the material are under
the control of the user; therefore, it is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use.
Product Name: General Purpose Viscosity
Standard � N.4
Revision Date: March 26, 2007

Page 5 of 12
MSDS ref CII07-007

ENVIRONMENTAL PRECAUTIONS
As above, Prevent spilled material from entering sewers, storm drains, other unauthorized drainage systems, and
natural waterways. Prevent contact with soil

SECTION 7 HANDLING AND STORAGE

HANDLING
Open container slowly to relieve any pressure. Bond and ground all equipment when transferring from one vessel to
another.Can accumulate static charge by flow or agitation. Can be ignited by static discharge. The use of explosion-
proof electrical equipment is recommended and may be required (see appropriate fire codes). Refer to NFPA-704
and/or API RP 2003 for specific bonding/grounding requirements. Wash thoroughly after handling. Do not wear
contaminated clothing or shoes. Keep contaminated clothing away from sources of ignition such as sparks or open
flames. Use good personal hygiene practices.

"Empty" containers retain residue and may be dangerous. Do not pressurize, cut, weld, braze, solder, drill, grind, or
expose such containers to heat, flame, sparks, or other sources of ignition. They may explode and cause injury or
death. "Empty" drums should be completely drained, properly bunged, and promptly shipped to the supplier or a drum
reconditioner. All containers should be disposed of in an environmentally safe manner and in accordance with
governmental regulations.


Loading/unloading temperature (°C/°F): Ambient
Transport temperature (°C/°F): Ambient
Transport pressure (kPa): Ambient
Static accumulator: Yes

STORAGE
Keep container(s) tightly closed. Use and store this material in cool, dry, well-ventilated areas away from heat, direct
sunlight, hot metal surfaces, and all sources of ignition. Post area "No Smoking or Open Flame." Store only in
approved containers. Keep away from any incompatible material (see Section 10). Protect container(s) against
physical damage. Outdoor or detached storage is preferred. Indoor storage should meet OSHA standards and
appropriate fire codes.

Storage temperature (°C/°F): Ambient
Storage pressure (kPa) Ambient
Suitable materials and coatings: Ambient
Unsuitable materials and coatings: Ambient

SPECIFIC USES:
Cannon Instruments supplies this product as a laboratory calibration standard and reagent. It is an
industrial hydrocarbon/ solvent with myriad additional uses. However, the advice in this MSDS is
intended for only the recommended/ supplied application. Seek expert advice before using this product
for other purposes.


SECTION 8 EXPOSURE CONTROLS/PERSONAL PROTECTION

EXPOSURE LIMITS/STANDARDS

WORKPLACE EXPOSURE GUIDELINES

This information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. The information
and recommendations contained herein is compiled from suppliers� MSDS and are accurate and reliable to the best of Cannon Instrument Company’s knowledge and belief as of the
indicated revision date. No representation, warranty or guarantee, however, is made with regards to accuracy, reliability or completeness. Conditions of use of the material are under
the control of the user; therefore, it is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use.
Product Name: General Purpose Viscosity
Standard � N.4
Revision Date: March 26, 2007

Page 6 of 12
MSDS ref CII07-007

OSHA REGULATION 29CFR1910.1000 PERMISSIBLE EXPOSURE LIMITS:
Normal hexane: 50 ppm (180 mg/m3) TWA with a “skin� notation
Other Hexane isomers: 500 ppm (1800 mg/m3) TWA and a STEL of 1000 ppm (3600 mg/m3).

ACGIH THRESHOLD LIMIT VALUES:
Normal hexane: 50 ppm (180 mg/m3) TWA with a “skin� notation
Other Hexane isomers: 500 ppm (1800 mg/m3) TWA and a STEL of 1000 ppm (3600 mg/m3).

ENGINEERING CONTROLS
The level of protection and types of controls necessary will vary depending upon potential exposure
conditions. Engineering controls are preferable to personal protective equipment. If current ventilation
practices are not adequate to maintain airborne concentrations below the established exposure limits (see
Section 2), additional engineering controls may be required. Where explosive mixtures may be present,
electrical systems safe for such locations must be used (see appropriate electrical codes).

PERSONAL PROTECTION
Personal protective equipment selections vary based on potential exposure conditions such as
applications, handling practices, concentration and ventilation. Information on the selection of protective
equipment for use with this material, as provided below, is based upon intended, normal usage.

Respiratory Protection:
If engineering controls do not maintain airborne contaminant concentrations at a level which is adequate
to protect worker health, an approved respirator may be appropriate. Respirator selection, use, and
maintenance must be in accordance with regulatory requirements, if applicable. Types of respirators to
be considered for this material include: (generic type - no filter/cartridge recommendation)

For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure
mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are
inadequate, gas/vapor warning properties are poor, or if air purifying filter capacity/rating may be
exceeded.

Hand Protection:
Any specific glove information provided is based on published literature and glove manufacturer data.
Replace worn or damaged gloves. The types of gloves to be considered for this material include: nitrile,
polyvinyl alcohol, or Viton® (see glove manufacturer literature for information on permeability).

Eye Protection:
The use of a face shield and chemical goggles to safeguard against potential eye contact, irritation, or
injury is recommended.

Skin and Body Protection:
The use of gloves impervious to the specific material handled is advised to prevent skin contact, possible
irritation, and skin damage. Examples of approved materials are nitrile, polyvinyl alcohol, or Viton® (see
manufacturer literature for information on permeability). Depending on conditions of use, apron and/or
arm covers may be necessary.
Specific Hygiene Measures:
Always observe good personal hygiene measures, such as washing after handling the material and
before eating, drinking, and/or smoking. Routinely wash work clothing and personal protective equipment
to remove contaminants. Discard contaminated clothing and footwear that cannot be cleaned.

This information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. The information
and recommendations contained herein is compiled from suppliers� MSDS and are accurate and reliable to the best of Cannon Instrument Company’s knowledge and belief as of the
indicated revision date. No representation, warranty or guarantee, however, is made with regards to accuracy, reliability or completeness. Conditions of use of the material are under
the control of the user; therefore, it is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use.
Product Name: General Purpose Viscosity
Standard � N.4
Revision Date: March 26, 2007

Page 7 of 12
MSDS ref CII07-007

ENVIRONMENTAL CONTROLS
See section 6, 7, 12, 13.

SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES

Typical physical and chemical properties are given below. Consult the Cannon Instrument Company as
indicated in Section 1 for additional data.

GENERAL INFORMATION
Physical state: Liquid
Form: Liquid
Color: Colorless
Odor: Mild petroleum solvent odor
Odor threshold: Not available

IMPORTANT HEALTH, SAFETY AND ENVIRONMENTAL INFORMATION

Relative density (formerly Specific Gravity): 0.664 @ 15.6°C
Bulk density g/cc: Not available
Density: 5.53 lb/gal @ 15.6°C ( 60°F )
Flash point °C (°F) [method]: -26°C / -15°F (TCC, ASTM D-56)
Flammable limits (approx. Volume % in air) - LEL: 1.2 UEL: 7.7
Ignition temperature (polymers) °C (°F): Not available
Autoignition temperature °C (°F): 437°F / 225°C
Boiling point/range °C (°F): 67°C (152.6°F) to 69°C (156.2°F)
Vapor density (Air=1): 3 Approximate
Vapor pressure: 2.5 psia @ 21°C
Evaporation rate: >1
pH: Not applicable
Log Pow (n-Octanol/water partition coefficient): Not available
Solubility in water (20 °C): Negligible

Viscosity @ 40°C cSt (mm2/sec): See product specification
100°C cSt (mm2/sec): See product specification


OTHER INFORMATION
Freezing point °C (°F): -95°C (-139°F)
Melting Point °C (°F): -95°C (-139°F)
Pour point °C (°F): Not available
Molecular weight: 86
Hygroscopic: No
Coefficient of thermal expansion: Not available

SECTION 10 STABILITY AND REACTIVITY

STABILITY:

This information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. The information
and recommendations contained herein is compiled from suppliers� MSDS and are accurate and reliable to the best of Cannon Instrument Company’s knowledge and belief as of the
indicated revision date. No representation, warranty or guarantee, however, is made with regards to accuracy, reliability or completeness. Conditions of use of the material are under
the control of the user; therefore, it is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use.
Product Name: General Purpose Viscosity
Standard � N.4
Revision Date: March 26, 2007

Page 8 of 12
MSDS ref CII07-007
Stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
Extremely flammable liquid and vapor. Vapor can cause flash fire.

CONDITIONS TO AVOID:
Avoid all possible sources of ignition (see Sections 5 and 7).

MATERIALS TO AVOID:
Avoid contact with acids and oxidizers such as chlorine and other halogens, chromates, perchlorates, peroxides and
oxygen.

HAZARDOUS DECOMPOSITION PRODUCTS:
Combustion can yield carbon dioxide, carbon monoxide.

HAZARDOUS POLYMERIZATION:
Will not occur.

SECTION 11 TOXICOLOGICAL INFORMATION

CHRONIC DATA:
Target Organs: Excessive exposure to n-hexane can result in peripheral neuropathies. The initial
symptoms are symmetrical sensory numbness and paresthesias of distal portions of the extremities.
Motor weakness is typically observed in muscles of the toes and fingers but may also involve muscles of
the arms, thighs and forearms. The onset of these symptoms may be delayed for several months to a
year after the beginning of exposure. The neurotoxic properties of n-hexane are potentiated by exposure
to methyl ethyl ketone and methyl isobutyl ketone.

Prolonged exposure to high concentrations of n-hexane (>1,000 ppm) has resulted in decreased sperm
count and degenerative changes in the testes of rats but not those of mice.

Other Hexanes - CAS: VARIOUS
Target Organs: A mixture of hexane isomers, free of n-hexane, did not produce neurotoxic effects in rats
exposed to 500 ppm for six months.

ACUTE DATA:
n-Hexane - CAS: 110-54-3
Dermal LD50 = >2,000 mg/kg (Rabbit)
LC50 = >3,367 ppm (4-hr., Rat)
Oral LD50 = > 5,000 mg/kg (Rat): 28.7 g/kg(Rat)

Other Hexanes - CAS: VARIOUS
Dermal LD50 = >2,000 mg/kg (Rabbit) (based on n-Hexane)
LC50 = >3,367 ppm (4-hr., Rat) (based on n-Hexane)
Oral LD50 = >5,000 mg/kg (Rat) (based on n-Hexane)

SECTION 12 ECOLOGICAL INFORMATION

Supplier of this product have not provided any relevant data/ information




This information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. The information
and recommendations contained herein is compiled from suppliers� MSDS and are accurate and reliable to the best of Cannon Instrument Company’s knowledge and belief as of the
indicated revision date. No representation, warranty or guarantee, however, is made with regards to accuracy, reliability or completeness. Conditions of use of the material are under
the control of the user; therefore, it is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use.
Product Name: General Purpose Viscosity
Standard � N.4
Revision Date: March 26, 2007

Page 9 of 12
MSDS ref CII07-007

ECOTOXICITY
No data are available

MOBILITY
No data are available

PERSISTENCE AND DEGRADABILITY
Biodegradation: No data are available
Hydrolysis: No data are available
Photolysis: No data are available
Atmospheric oxidation: No data are available

BIOACCUMULATION POTENTIAL
No data are available

OTHER ECOLOGICAL INFORMATION
VOC: No data are available
COD: No data are available

SECTION 13 DISPOSAL CONSIDERATIONS

Disposal recommendations are based on material as supplied. Disposal must be in accordance with
current applicable laws and regulations, and material characteristics at time of disposal.

DISPOSAL RECOMMENDATIONS

This material, if discarded as produced, would be a RCRA "characteristic" hazardous waste due to the
characteristic(s) of ignitability (D001). If the spilled or released material impacts soil, water, or other
media, characteristic testing of the contaminated materials may be required prior to their disposal.
Further, this material, once it becomes a waste, is subject to the land disposal restrictions in 40 CFR
268.40 and may require treatment prior to disposal to meet specific standards. Consult state and local
regulations to determine whether they are more stringent than the federal requirements. Container
contents should be completely used and containers should be emptied prior to discard. Container rinsate
could be considered a RCRA hazardous waste and must be disposed of with care and in full compliance
with federal, state and local regulations. Larger empty containers, such as drums, should be returned to
the distributor or to a drum reconditioner. To assure proper disposal of smaller empty containers, consult
with state and local regulations and disposal authorities.

REGULATORY DISPOSAL INFORMATION

Empty container warning (where applicable): empty containers may retain residue and can be
dangerous. Do not pressurize, cut, weld, braze, solder, drill, grind or expose such containers to heat,
flame, sparks, static electricity, or other sources of ignition; they may explode and cause injury or death.
Do not attempt to refill or clean container since residue is difficult to remove. Empty drums should be
completely drained, properly bunged and promptly returned to a drum reconditioner. All containers
should be disposed of in an environmentally safe manner and in accordance with governmental
regulations.

SECTION 14 TRANSPORT INFORMATION

This information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. The information
and recommendations contained herein is compiled from suppliers� MSDS and are accurate and reliable to the best of Cannon Instrument Company’s knowledge and belief as of the
indicated revision date. No representation, warranty or guarantee, however, is made with regards to accuracy, reliability or completeness. Conditions of use of the material are under
the control of the user; therefore, it is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use.
Product Name: General Purpose Viscosity
Standard � N.4
Revision Date: March 26, 2007

Page 10 of 12
MSDS ref CII07-007


Note: The information provided below may not apply to all shipping situations. Consult appropriate
Dangerous Goods Regulations for additional requirements and mode-specific, material-specific, or
quantity-specific shipping requirements.

United States Department of Transportation (US DOT):
UN/ID# Proper Shipping Name Class/Division Hazard Label(s) Packing Group
UN1208 Hexanes 3 Flammable Liquid II


International Air Transport Association (IATA):
UN/ID# Proper Shipping Name Class/Division Hazard Label(s) Packing Group
UN1208 Hexanes 3 Flammable Liquid II



SECTION 15 REGULATORY INFORMATION

OSHA HAZARD COMMUNICATION STANDARD: When used for its intended purposes, this material is
classified as hazardous in accordance with OSHA 29 CFR
1910.1200.

NATIONAL CHEMICAL INVENTORY LISTING:

This product, and/ or its constituents, is listed on the US EPA/ TSCA (Toxic Substances Control Act)
Inventory

COMMUNITY RTK:
Chemical Name CAS Number
Normal hexane 110-54-3
Other hexane isomers various

CERCLA:

Chemical Name CAS Number Typical Value Component TPQ
Normal hexane 110-54-3 >85% 5,000 pounds
Other hexane isomers --- <15% 5,000 pounds


SARA (311/312) REPORTABLE HAZARD CATEGORIES:

Acute Health: Yes
Chronic Health: Yes
Fire Hazard: Yes
Pressure Hazard: No

This information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. The information
and recommendations contained herein is compiled from suppliers� MSDS and are accurate and reliable to the best of Cannon Instrument Company’s knowledge and belief as of the
indicated revision date. No representation, warranty or guarantee, however, is made with regards to accuracy, reliability or completeness. Conditions of use of the material are under
the control of the user; therefore, it is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use.
Product Name: General Purpose Viscosity
Standard � N.4
Revision Date: March 26, 2007

Page 11 of 12
MSDS ref CII07-007

Reactive Hazard: No

SARA (313) TOXIC RELEASE INVENTORY:

This material contains the following chemicals subject to the reporting requirements of SARA 313 and 40
CFR 372:
n-Hexane................110-54-3................>60%

International chemical inventories and hazard classifications
This product and/ or its components are on the Canadian Domestic Substance List/ NDSL
WHMIS Classifications (Canada):
B2 - Flammable and combustible material - Flammable liquid
D2B - Poisonous and infectious material - Other effects � Toxic



WHMIS Health Effects Criteria Met by this Chemical:
D2B - Chronic toxicity - toxic - other
WHMIS Ingredient Disclosure List:
Not included. Meets criteria for disclosure at 1% or greater.

This product and/ or its components are on EINECS (European Inventory of Existing Chemical
Substances) and/ or ELINCS (European Library of Notified Chemical Substances)
EU Hazard Classification, risk and safety phrases (Europe):


F: Highly Xn: N: Dangerous for
Flammable Harmful the Environment
R11: Highly flammable
R38: Irritating to skin
R48/20: Harmful: danger of serious damage to health by prolonged exposure through
inhalation
R62: Possible risk of impaired fertility
R65: Harmful: may cause lung damage if swallowed
R67: Vapours may cause drowsiness of dizziness
R51/53: Toxic to aquatic organisms, may cause long-term adverse effects in the aquatic
environment
S2: Keep out of reach of children
S9: Keep container in a well ventilated place
S16: Keep away from sources of ignition - No smoking
S29: Do not empty into drains
S33: Take precautionary measures against static discharges
S36/37: Wear suitable protective clothing and gloves
S61: Avoid release to the environment. Refer to special instructions/safety data sheet
S62: If swallowed, do not induce vomiting: seek medical advice immediately and show
this container or label

SECTION 16 OTHER INFORMATION


This information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. The information
and recommendations contained herein is compiled from suppliers� MSDS and are accurate and reliable to the best of Cannon Instrument Company’s knowledge and belief as of the
indicated revision date. No representation, warranty or guarantee, however, is made with regards to accuracy, reliability or completeness. Conditions of use of the material are under
the control of the user; therefore, it is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use.
Product Name: General Purpose Viscosity
Standard � N.4
Revision Date: March 26, 2007

Page 12 of 12
MSDS ref CII07-007


THIS SAFETY DATA SHEET CONTAINS THE FOLLOWING REVISIONS:
Revision Summary:
� October 15, 2005 -- This MSDS has been fully reviewed and reformatted to conform to changes
in standard format
� January 5, 2007 -- Update information to be consistent with current supplier MSDS
� February 27, 2007: Added Canadian and European classification and labeling information,
based on current regulations and/or recommendations from suppliers (see Section 15)
� March 26, 2007: Updated and standardized format of Transport Information (see Section 14)


NOTES:




This information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. The information
and recommendations contained herein is compiled from suppliers� MSDS and are accurate and reliable to the best of Cannon Instrument Company’s knowledge and belief as of the
indicated revision date. No representation, warranty or guarantee, however, is made with regards to accuracy, reliability or completeness. Conditions of use of the material are under
the control of the user; therefore, it is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use.

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
camlee_com---msds-cda172.asp 7429-90-5 7440-36-0 7440-38-2 7440-41-7 7440-43-9 7440-47-3 7440-48-4 7440-50-8 1309-37-1 7439-92-1 7439-96-5 1309-48-4 7440-02-0 7723-14-0 7440-21-3
camlee_com---msds-cda220.asp 7429-90-5 7440-36-0 7440-38-2 7440-41-7 7440-43-9 7440-47-3 7440-48-4 7440-50-8 1309-37-1 7439-92-1 7439-96-5 1309-48-4 7440-02-0 7723-14-0 7440-21-3
camlee_com---msds-cda230.asp 7429-90-5 7440-36-0 7440-38-2 7440-41-7 7440-43-9 7440-47-3 7440-48-4 7440-50-8 1309-37-1 7439-92-1 7439-96-5 1309-48-4 7440-02-0 7723-14-0 7440-21-3
camlee_com---msds-cda260.asp 7429-90-5 7440-36-0 7440-38-2 7440-41-7 7440-43-9 7440-47-3 7440-48-4 7440-50-8 1309-37-1 7439-92-1 7439-96-5 1309-48-4 7440-02-0 7723-14-0 7440-21-3
camlee_com---msds-cda280.asp 7429-90-5 7440-36-0 7440-38-2 7440-41-7 7440-43-9 7440-47-3 7440-48-4 7440-50-8 1309-37-1 7439-92-1 7439-96-5 1309-48-4 7440-02-0 7723-14-0 7440-21-3
camlee_com---msds-cda314.asp 7429-90-5 7440-36-0 7440-38-2 7440-41-7 7440-43-9 7440-47-3 7440-48-4 7440-50-8 1309-37-1 7439-92-1 7439-96-5 1309-48-4 7440-02-0 7723-14-0 7440-21-3
camlee_com---msds-cda353.asp 7429-90-5 7440-36-0 7440-38-2 7440-41-7 7440-43-9 7440-47-3 7440-48-4 7440-50-8 1309-37-1 7439-92-1 7439-96-5 1309-48-4 7440-02-0 7723-14-0 7440-21-3
camlee_com---msds-cda360.asp 7429-90-5 7440-36-0 7440-38-2 7440-41-7 7440-43-9 7440-47-3 7440-48-4 7440-50-8 1309-37-1 7439-92-1 7439-96-5 1309-48-4 7440-02-0 7723-14-0 7440-21-3
camlee_com---msds-cda464.asp 7429-90-5 7440-36-0 7440-38-2 7440-41-7 7440-43-9 7440-47-3 7440-48-4 7440-50-8 1309-37-1 7439-92-1 7439-96-5 1309-48-4 7440-02-0 7723-14-0 7440-21-3
camlee_com---msds-cda544.asp 7429-90-5 7440-36-0 7440-38-2 7440-41-7 7440-43-9 7440-47-3 7440-48-4 7440-50-8 1309-37-1 7439-92-1 7439-96-5 1309-48-4 7440-02-0 7723-14-0 7440-21-3
camlee_com---msds_f-300_rev_1.asp 7440-50-8
cannoninstrument_com---cannon_msds_cii05-001_petroleum_hydrocarbons.asp N/A
cannoninstrument_com---cannon_msds_cii05-010_general_purpose_viscosity_standard_pet.asp N/A
cannoninstrument_com---cannon_msds_cii05-013_cold_cranking_simulator_standards.asp N/A
cannoninstrument_com---cannon_msds_cii05-025_bath_oil_petroleum_white_oil.asp N/A
cannoninstrument_com---cannon_msds_cii05-027_miscellaneous_viscosity_standards_.asp N/A
cannoninstrument_com---cannon_msds_cii05_015_low_temperature_viscosity_standards___.asp N/A
cannoninstrument_com---cannon_msds_cii05_016_high_temperature_viscosity_standards_p.asp N/A
cannoninstrument_com---cannon_msds_cii07-002_miscellanous_viscosity_standards_hyd.asp N/A
cannoninstrument_com---cannon_msds_cii07-003_miscellanous_viscosity_standards_syn.asp N/A
cannoninstrument_com---cannon_msds_cii07-004_dow_corning_fluids_all_grades.asp N/A
cannoninstrument_com---cannon_msds_cii07-005_msds_silicone_bath_oil.asp N/A
cannoninstrument_com---cannon_msds_cii07-006_thermometers_with_mercury-thallium.asp 7439-97-6 7440-28-0
cannoninstrument_com---cannon_msds_cii07-007_general_purpose_visc_std_n-4_hexanes.asp 110-54-3
cannoninstrument_com---cannon_msds_cii07-008_general_purpose_visc_std_n-8_xylene.asp 108-38-3 95-47-6 106-42-3 100-41-4
cannoninstrument_com---cannon_msds_cii07-009_general_purpose_visc_std_n1_decane.asp 124-18-5
cannoninstrument_com---cannon_msds_cii07-011_miscellanous_viscosity_standards_syn.asp N/A
cannoninstrument_com---cannon_msds_cii07-012_general_purpose_viscosity_standards.asp N/A
cannoninstrument_com---cannon_msds_cii07-014_low_temperature_viscosity_standards.asp N/A
cannoninstrument_com---cannon_msds_cii07-015_low_temperature_viscosity_standards.asp N/A
cannoninstrument_com---cannon_msds_cii07-016_high_temperature_viscosity_standards.asp N/A
cannoninstrument_com---cannon_msds_cii07-017_high_temperature_viscosity_standards.asp N/A
cannoninstrument_com---cannon_msds_cii07-018_fprm10.asp 124-18-5
cannoninstrument_com---cannon_msds_cii07-020_fprm14.asp N/A
cannoninstrument_com---cannon_msds_cii07-021_fprm16.asp N/A
cannoninstrument_com---cannon_msds_cii07-022_fprm2d_synthetic_base_oil.asp N/A
cannoninstrument_com---cannon_msds_cii07-024_fprm4d_synthetic_base_oil.asp N/A
cannoninstrument_com---cannon_msds_cii07-028_certified_check_oil.asp 64742-54-7 64741-88-4
caymanchem_com---10004914m.asp 536697-79-7 79-20-9
caymanchem_com---10004916m.asp 67-68-5
caymanchem_com---10004995m.asp N/A
caymanchem_com---10005174m.asp 580-72-3
caymanchem_com---10005270m.asp 191282-48-1
caymanchem_com---10005368m.asp 49562-28-9
caymanchem_com---10005673m.asp 137252-25-6 79-20-9
caymanchem_com---10005726m.asp 9005-64-5
caymanchem_com---10006084m.asp 520-33-2
caymanchem_com---10006211m.asp 22888-70-6
caymanchem_com---10006307m.asp 26628-22-8
caymanchem_com---10006427m.asp 633-65-8

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC