Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

353-87-7
7647-01-0

File Name: camlab_co_uk---rn_pau2a8.asp
                                                                                                                    Page 1/5
Safety Data Sheet
according to 1907/2006/EC, Article 31
Printing date 01.06.2007 version number 7 Revision: 22.12.2006

1 Identification of the substance/preparation and of the company/undertaking
*Trade name: GOLD ICP STANDARD SOLUTION
*Article number: PAU2A8
*Application of the substance / the preparation Laboratory chemicals
*Manufacturer/Supplier:
Reagecon Diagnostics Ltd.
Shannon Free Zone,
Shannon,
Co. Clare,
IRL.

Tel +353 61 472622
Fax +353 61 472642
*Further information obtainable from:
Health & Safety Department Ext 648
EMERGENCY CONTACT NUMBER AVAILABLE 08.00 to 22.00 :- 353-87-7828692
email: sean.murphy@reagecon.ie


2 Hazards identification
*Hazard description:


Xi Irritant


*Information concerning to particular hazards to man and environment:
The product has been classified and labelled in accordance with EU Directive 99/45/EC and all other EU
Directives referred to therein.
R 36/38 Irritating to eyes and skin.
*Classification system:
The classification is according to the latest editions of the EU-lists, and extended by company and literature data.


3 Composition/information on ingredients
*Chemical characterization
*Description: Mixture of substances listed below with nonhazardous additions.
*Dangerous components:
CAS: 7647-01-0 hydrogen chloride C, Xi; R 34-37 2.5-10%
EINECS: 231-595-7
*Additional information: For the wording of the listed risk phrases refer to section 16.


4 First-aid measures
*After inhalation: In case of unconsciousness place patient stably in side position for transportation.
*After skin contact: Immediately wash with water and soap and rinse thoroughly.
(Contd. on page 2)
IRL




DR
Page 2/5
Safety Data Sheet
according to 1907/2006/EC, Article 31
Printing date 01.06.2007 version number 7 Revision: 22.12.2006

Trade name: GOLD ICP STANDARD SOLUTION

(Contd. of page 1)
*After eye contact:
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
*After swallowing: If symptoms persist consult doctor.


5 Fire-fighting measures
*Suitable extinguishing agents:
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
*Protective equipment: No special measures required.


6 Accidental release measures
*Person-related safety precautions: Not required.
*Measures for environmental protection:
Dilute with plenty of water.
Do not allow to enter sewers/ surface or ground water.
*Measures for cleaning/collecting:
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
Ensure adequate ventilation.


7 Handling and storage
*Handling:PPE to be worn. See section 8
*Information for safe handling:
Ensure good ventilation/exhaustion at the workplace.
Prevent formation of aerosols.
*Information about fire - and explosion protection: No special measures required.
*Storage:
*Requirements to be met by storerooms and receptacles: No special requirements.
*Information about storage in one common storage facility: Not required.
*Further information about storage conditions: Keep receptacle tightly sealed.


8 Exposure controls/personal protection
*Additional information about design of technical facilities: No further data; see item 7.
*Ingredients with limit values that require monitoring at the workplace:
7647-01-0 hydrogen chloride
OELV (Ireland) Short-term value: 14 mg/m鲁, 10 ppm
Long-term value: 7 mg/m鲁, 5 ppm
PEL (USA) Short-term value: C 7 mg/m鲁, C 5 ppm
REL (USA) Short-term value: C 7 mg/m鲁, C 5 ppm
TLV (USA) Short-term value: C 2.98 mg/m鲁, C 2 ppm
IOELV (European Union) Short-term value: 15 mg/m鲁, 10 ppm
Long-term value: 8 mg/m鲁, 5 ppm
(Contd. on page 3)
IRL




DR
Page 3/5
Safety Data Sheet
according to 1907/2006/EC, Article 31
Printing date 01.06.2007 version number 7 Revision: 22.12.2006

Trade name: GOLD ICP STANDARD SOLUTION

(Contd. of page 2)
*Additional information: The lists valid during the making were used as basis.
*Personal protective equipment:
*General protective and hygienic measures:
Keep away from foodstuffs, beverages and feed.
Immediately remove all soiled and contaminated clothing
Wash hands before breaks and at the end of work.
Do not inhale gases / fumes / aerosols.
Avoid contact with the eyes and skin.
*Respiratory protection:
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use
self-contained respiratory protective device.
*Protection of hands:


Protective gloves


The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.
Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the
chemical mixture.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation
*Material of gloves
The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and
varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance
of the glove material can not be calculated in advance and has therefore to be checked prior to the application.
*Penetration time of glove material
The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be
observed.
*Eye protection:


Tightly sealed goggles




9 Physical and chemical properties
*General Information
Liquid
Form:
According to product specification
Colour:
Characteristic
Odour:
*Change in condition
Melting point/Melting range: Undetermined.
Boiling point/Boiling range: 85掳C
Not applicable.
*Flash point:
(Contd. on page 4)
IRL




DR
Page 4/5
Safety Data Sheet
according to 1907/2006/EC, Article 31
Printing date 01.06.2007 version number 7 Revision: 22.12.2006

Trade name: GOLD ICP STANDARD SOLUTION

(Contd. of page 3)

Product is not selfigniting.
*Self-igniting:
Product does not present an explosion hazard.
*Danger of explosion:
Not determined.
*Density:
*Solubility/ miscibility with
Fully miscible.
water:
*Solvent content:
0.0 %
Organic solvents:



10 Stability and reactivity
*Thermal decomposition / conditions to be avoided: No decomposition if used according to specifications.
*Dangerous reactions No dangerous reactions known.
*Dangerous decomposition products: No dangerous decomposition products known.


11 Toxicological information
*Acute toxicity:
*Primary irritant effect:
*on the skin: Irritant to skin and mucous membranes.
*on the eye: Irritating effect.
*Sensitization: No sensitizing effects known.
*Additional toxicological information:
The product shows the following dangers according to the calculation method of the General EU Classification
Guidelines for Preparations as issued in the latest version:
Irritant


12 Ecological information
*General notes:
Water hazard class 1 (German Regulation) (Self-assessment): slightly hazardous for water
Do not allow undiluted product or large quantities of it to reach ground water, water course or sewage system.


13 Disposal considerations
*Product:
*Recommendation
Must not be disposed together with household garbage. Do not allow product to reach sewage system.
*Uncleaned packaging:
*Recommendation: Disposal must be made according to official regulations.
(Contd. on page 5)
IRL




DR
Page 5/5
Safety Data Sheet
according to 1907/2006/EC, Article 31
Printing date 01.06.2007 version number 7 Revision: 22.12.2006

Trade name: GOLD ICP STANDARD SOLUTION

(Contd. of page 4)
*Recommended cleansing agents: Water, if necessary together with cleansing agents.


14 Transport information
*Land transport ADR/RID (cross-border)
*ADR/RID class: -
*Maritime transport IMDG:
*Marine pollutant: No
*Transport/Additional information: Not dangerous according to the above specifications.


15 Regulatory information
*Labelling according to EU guidelines:
Observe the general safety regulations when handling chemicals.
The product has been classified and marked in accordance with EU Directive 99/45/EC and all other EU
Directives referred to therein.
*Code letter and hazard designation of product:


Xi Irritant


*Risk phrases:
36/38 Irritating to eyes and skin.
*Safety phrases:
20 When using do not eat or drink.
23 Do not breathe fumes/aerosol.
26 In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
36/37/39 Wear suitable protective clothing, gloves and eye/face protection.
45 In case of accident or if you feel unwell, seek medical advice immediately (show the label where
possible).
60 This material and its container must be disposed of as hazardous waste.
*National regulations:
*Waterhazard class: Water hazard class 1 (Self-assessment): slightly hazardous for water.


16 Other information
This information is based on our present knowledge. However, this shall not constitute a guarantee for any
specific product features and shall not establish a legally valid contractual relationship.
*Department issuing MSDS: Safety Officer
*Contact: Mr. Sean Murphy
IRL




DR

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
camlab_co_uk---rn_10705ctt.asp 353-87-7
camlab_co_uk---rn_107429.asp 353-87-7
camlab_co_uk---rn_1100.asp 353-87-7
camlab_co_uk---rn_110000c.asp 353-87-7
camlab_co_uk---rn_11002ctt.asp 353-87-7
camlab_co_uk---rn_11005c.asp 353-87-7
camlab_co_uk---rn_11005ctt.asp 353-87-7
camlab_co_uk---rn_cp1040.asp 353-87-7 877-24-7
camlab_co_uk---rn_cs1382.asp 353-87-7
camlab_co_uk---rn_cskc100.asp 353-87-7
camlab_co_uk---rn_cskc84.asp 353-87-7
camlab_co_uk---rn_ecs.asp 353-87-7
camlab_co_uk---rn_ep133.asp 353-87-7
camlab_co_uk---rn_iecs5.asp 353-87-7
camlab_co_uk---rn_pal2b2.asp 353-87-7 7697-37-2 7784-27-2
camlab_co_uk---rn_pas2b3.asp 353-87-7 7647-01-0 45-28-3 1327-53-3
camlab_co_uk---rn_pau2a8.asp 353-87-7 7647-01-0
camlab_co_uk---rn_pb2a7.asp 353-87-7
camlab_co_uk---rn_pb2b7.asp 353-87-7
camlab_co_uk---rn_pbe2b2.asp 353-87-7 7697-37-2 49-25-2 7440-41-7
camlab_co_uk---rn_pca4b2.asp 353-87-7 471-34-1 7697-37-2
camlab_co_uk---rn_pca4b3.asp 353-87-7 7647-01-0 471-34-1
camlab_co_uk---rn_pfe2b2.asp 353-87-7 7697-37-2
camlab_co_uk---rn_pge2b7.asp 353-87-7
camlab_co_uk---rn_pin2a2.asp 353-87-7 7697-37-2
camlab_co_uk---rn_pla2a2.asp 353-87-7 7697-37-2
camlab_co_uk---rn_pla2b2.asp 353-87-7 7697-37-2
camlab_co_uk---rn_pmg4b2.asp 353-87-7 7697-37-2 7439-95-4
camlab_co_uk---rn_tb100.asp 353-87-7
camlab_co_uk---rn_tb921.asp 353-87-7 1330-43-4
camlab_co_uk---tt_380290.asp 111-46-6 7732-18-5
camlab_co_uk---tt_459300.asp 7732-18-5
camlab_co_uk---tt_461181.asp 7697-37-2 004-00-1
camlab_co_uk---tt_462910.asp 7681-38-1 100-10-7
camlab_co_uk---tt_471010.asp N/A
camlab_co_uk---tt_471020.asp 7664-93-9 020-00-8 6283-63-2
camlab_co_uk---tt_502940.asp 10034-88-5 124-04-9 144-00-9
camlab_co_uk---tt_511060.asp 6283-63-2
camlab_co_uk---tt_511080.asp N/A
camlab_co_uk---tt_511220.asp 6283-63-2
camlab_co_uk---tt_511320.asp 77-92-9
camlab_co_uk---tt_512310.asp 7681-38-1 121-57-3
camlab_co_uk---tt_512350.asp 7632-00-0 010-00-4
camlab_co_uk---tt_512380.asp 6283-63-2
camlab_co_uk---tt_512390.asp 6381-92-6
camlab_co_uk---tt_512580.asp 69-72-7 13755-38-9
camlab_co_uk---tt_512590.asp 1310-66-3 22-31-3 51580-86-0 030-01-7
camlab_co_uk---tt_512620.asp N/A
camlab_co_uk---tt_513040.asp 7681-38-1 124-04-9 144-00-9 28300-74-5 003-00-9
camlab_co_uk---tt_513050.asp 7681-57-4 063-00-2 12054-85-2

Free MSDS Search ( Providing 250,000+ Material Properties )