nylon 66
msds toxicity property">
Search   
MSDS  : "ZYTEL" NYLON RESINS IN SYNONYM LIST OF ZYT022
CAS  : 32131-17-2
NAME  : non-regulated lubricants & stabalizers
nylon 66
DUPONT ENGINEERING POLYMERS -- "ZYTEL" NYLON RESINS IN SYNONYM LIST OF ZYT02
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CKXGB
MSDS NAME: "ZYTEL" NYLON RESINS IN SYNONYM LIST OF ZYT022
Responsible Party
Name: DUPONT ENGINEERING POLYMERS
Address: 1007 MARKET STREET
City: WILMINGTON DE 19898
Info Phone: 1-800-441-7515
Emergency Phone Number: 1-800-441-3637
Resp. Party Other MSDS No.: ZYT022
Preparer's Name: J. P. BOLLMEIER
Chemtrec IND/Phone: (800)424-9300
Review Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: DUPONT ENGINEERING POLYMERS
Address: 1007 MARKET STREET
City: WILMINGTON DE 19898
Phone: 1-800-441-7515
=======================================================
Ingredients
=======================================================
Name: NON-REGULATED LUBRICANTS & STABALIZERS
< Wt: 2.
-----------------------------
Cas: 32131-17-2
Name: NYLON 66
> Wt: 98.
Other REC Limits: 10 MG/M3, 5 MG/M3 R
OSHA PEL: 15 MG/M3, 5 MG/M3 R
ACGIH TLV: NONE ESTABLISHED
=======================================================
Health Hazards Data
=======================================================
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: POLYHEXAMETHYLENE ADIPAMIDE:SKIN IRRITATION NOT PRODUCED
IN HUMAN PATCH TESTS WITH NYLON 66. HOWEVER, A SMALL PERCENTAGE OF SUBJECTS
MAY RESPOND TO PROLONGED CONTACT WITH REDNESS OF SKIN. SIGNIFICANT SKIN
PERMEATION, OR SYSTEMIC TOXICITY, AFTER CONTACT APPEARS UNLIKELY. THERE ARE
NO REPORTS OF HUMAN SENSITIZATION. IF PARTICLES OF NYLON 66 CONTACT THE EYE
, MECHANICAL IRRITATION WITH TEARING, PA IN OR BLURRED VISION MAY RESULT.
ADDITIONAL HEALTH EFFECTS: READ "ZYTEL" MOLDING GUIDE BEFORE USING THIS
PRODUCT.
Explanation Of Carcinogenicity: NONE OF THE COMPONENTS PRESENT IN THIS MATERIAL
AT CONCENTRATIONS EQUAL TO OR GREATER THAN 0.1% ARE LISTED BY IARC, NTP, OSHA
OR ACGIH AS A CARCINOGEN.
Signs And Symptions Of Overexposure: N/P. FIRST AID (CONT): LEAST 15
MINUTES. CALL A PHYSICIAN. INGESTION: NO SPECIFIC INTERVENTION IS INDICATED
A COMPOUND IS NOT LIKELY TO BE HAZARDOUS BY INGESTION. CONSULT A PHYSICIAN IF
NECESSAR Y.
First Aid: INHALATION: NO SPECIFIC INTERVENTION IS NECESSARY AS THE COMPOUND IS
NOT LIKELY TO BE HAZARDOUS BY INHALATION. CONSULT A PHYSICIAN IF NECESSARY.
IF EXPOSED TO FUMES FROM OVERHEATING OR COMBUSTION, MOV E TO FRESH AIR.
CONSULT A PHYSICIAN IF SYMPTOMS PERSIST. SKIN CONTACT: THE COMPOUND IS NOT
LIKELY TO BE HAZARDOUS BY SKIN CONTACT, BUT CLEANSING THE SKIN AFTER USE IS
ADVISABLE. IF MOLTEN POLYMER GETS ON SKIN, COOL RAPIDLY WITH COLD WATER. DO
NOT ATTEMPT TO PEEL POLYMER FROM SKIN. OBTAIN MEDICAL TREATMENT FOR THERMAL
BURN. EYES CONTACT: IN CASE OF CONTACT, IMMEDIATELY FLUSH WITH PLENTY OF
WATER FO R AT (SIGNS & SYMPTOMS OF OVEREXPOSURE)
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: SAFEGUARDS (PERSONNEL): NOTE: REVIEW FIRE FIGHTING
MEASURES AND HANDLING (PERSONNEL) SECTIONS BEFORE PROCEEDING WITH CLEAN-UP.
USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT DURING CLEAN-UP.
Waste Disposal Methods: PREFERRED OPTIONS FOR DISPOSAL ARE (1) RECYCLING, (2)
INCINERATION WITH ENERGY RECOVERY, AND (3) LANDFILL. THE HIGH FUEL VALUE OF
THIS PRODUCT MAKES OPTION 2 VERY DESIRABLE FOR MATERIAL THAT CANNOT BE
RECYCLED, BUT THE INCINERATOR MUST BE CAPABLE OF SCRUBBING OUT ACIDIC
COMBUSTION PRODUCTS. TREATMEN T, STORAGE, TRANSPORTATION & DISPOSAL
(OTHER INFO)
Handling And Storage Precautions: HANDLING (PERSONNEL): SEE FIRST AID AND
PERSONAL PROTECTIVE EQUIPMENT SECTIONS. STORAGE: STORE IN COOL, DRY PLACE.
KEEP CONTAINERS TIGHTLY CLOSED TO PREVENT MOISTURE ABSORPTION AND
CONTAMINATION.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point: =400.C, 752.F
Flash Point Text: METHOD: D1929
Extinguishing Media: WATER, FOAM, DRY CHEMICAL, CO2.
Fire Fighting Procedures: KEEP PERSONNEL UPWIND OF FIRE. WEAR SELF-CONTAINED
BREATHING APPARATUS (NIOSH APPROVED - FP N).
Unusual Fire/Explosion Hazard: LARGE MOLTEN MASSES MAY IGNITE SPONTANEOUSLY IN
AIR. WATER QUENCHING OF SUCH MASSES IS GOOD PRACTICE. HAZARDOUS GASES AND
VAPORS PRODUCED IN FIRE ARE AMMONIA AND CARBON MONOXIDE. SMALL AMOUNTS OF
HYDR OGEN CYANIDE AND ALDEHYDES.
=======================================================
Control Measures
=======================================================
Respiratory Protection: A NIOSH APPROVED AIR PURIFYING RESPIRATOR WITH AN
ORGANIC VAPOR CARTRIDGE WITH A DUST / MIST FILTER MAY BE PERMISSIBLE UNDER
CERTAIN CIRCUMSTANCES WHEN AIRBORNE CONCENTRATIONS EXPECTED TO EXCEED EXPOS
URE LIMITS. PROTECTION PROVIDED BY AIR PURIFYING RESPIRATORS IS LIMITED. USE
A (NIOSH APPROVED - FP N) POSITIVE PRESSURE AIR (SUPPLEMENTAL SAFETY AND
HEALTH)
Ventilation: USE LOCAL VENTILATION TO CONTROL FUMES FROM HOT PROCESSING.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: WEAR SAFETY GLASSES (ANSI APPROVED - FP N). WEAR COVERALL CHEM
(HYGENIC PRACT)
Other Protective Equipment: EYEWASH AND DELUGE SHOWER MEETING ANSI DESIGN
CRITERIA (FP N). PROTECTIVE CLOTHING: IF POTENTIAL CONTACT WITH HOT OR
MOLTEN MATERIAL, WEAR HEAT RESISTANT CLOTHING AND FOOTWEAR.
Work Hygienic Practices: N/P. EYE PROT (CONT): SPLASH GOGGLES & FACE SHIELD
WHEN POSSIBILITY EXISTS FOR EYE & FACE CONTACT DUE TO SPLASHING & SPRAYING OF
MOLTEN MATERIAL. A FULL FACE MASK RESP PROTECTS FROM EYE IRRITATION.
Supplemental Safety and Health: RESPIRATORY PROTECTION (CONT): SUPPLIED
RESPIRATOR IF THERE IS ANY POTENTIAL FORAN UNCONTROLLED RELEASE, EXPOSURE
LEVELS ARE NOT KNOWN, OR ANY OTHER CIRCUMSTANCES WHERE AIR PURIFYING
RESPIRATORS MAY N OT PROVIDE ADEQUATE PROTECTION.MAY NOT PROVIDE ADEQUATE
PROTECTION.
=======================================================
Physical/Chemical Properties
=======================================================
Melt/Freeze Pt: =250.C, 482.F
M.P/F.P Text: 250-260C (482-500F) NE
Spec Gravity: 1.22 - 1.38
Solubility in Water: INSOLUBLE
Appearance and Odor: GRANULES, NO ODOR.
Percent Volatiles by Volume: CA 1%- WATER
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: TEMPERATURES ABOVE 340C (644F).
Materials To Avoid: INCOMPATIBLE OR CAN REACT WITH STRONG ACIDS, OXIDIZING
AGENTS.
Hazardous Decomposition Products: HAZARDOUS GASES OR VAPORS CAN BE RELEASED,
INCLUDING: CYCLOPENTANONE, CARBON MONOXIDE, ALDEHYDES AND AMMONIA.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: POLYMERIZATION WILL NOT OCCUR.
=======================================================
Toxicological Information
=======================================================
Toxicological Information: ANIMAL DATA: NYLON 66 ORAL LD50, RAT: >10,000
MG/KG. NYLON 66 IS NOT A SKIN IRRITANT IN TESTS WITH ANIMALS. SINGLE EXPOSURE
BY INGESTION TO HIGH DOSES CAUSED DECREASED BODY WEIGHT. LONG-TERM EXPOSURE
CAUSED NO SIGNIFICANT TOXICOLOGICAL EFFECTS. REPEATED INHALATION EXPOSURE
CAUSED HISTOPATHOLOGICAL CHANGES OF LUNGS AND KIDNEYS. IN ANIMAL TESTING
NYLON 66 HAS NOT CAUSED CARCINOGENICITY. NO ANIMAL DA TA AVAILABLE TO DEFINE
DEVELOPMENTAL, REPRODUCTIVE, OR MUTAGENIC HAZARDS. EXPOSURE LIMITS: "ZYTEL"
NYLON RESINS IN SYNONYM LIST OF ZYT022: PEL (OSHA): PARTICULATES (NOT
OTHERWISE REGULATED); 15 MG/M 3, 8 HR TWA, TOTAL DUST; (SARA III)
=======================================================
Ecological Information
=======================================================
Ecological: AQUATIC TOXICITY: NO INFO AVAILABLE. TOXICITY EXPECTED LOW BASED ON
INSOLUBILITY IN WATER. TRADENAMES AND SYNONYMS: "ZYTEL" -- AFE1000
NC010; AFE1001 NC010; AFE1111 NC010; CFE1111 NC010; E50 NC01 0' E51HSB NC010;
E53 NC010; E55 NC010; E101L NC010; E103HSL NC010; EFE1068 NC010; EFE1117
NC010; EFE1150 NC010; EFE1151 NC010; FE1111 NC010; FE3370 NC010; FE3399
BK160; FE3399 BKB160; FE3415 NC010; FE 3421 NC010; FE3491 NC010; FE3491C
NC010; FE3583 NC010; FE3606 NC010; FE3653 NC010; FE3667 NC010; FE3677 NC010;
FE3684 NC010; FE3699 NC010; FE3701 NC010A; FE3704 NC010; FE3705 NC010; FE3706
NC010; FE37 38 NC010; FE3747 NC010; (TRANSPORT INFO)
=======================================================
MSDS Transport Information
=======================================================
Transport Information: SHIPPING INFO: DOT-PROPER SHIPPING NAME/TDG: NOT
REGULATED. ECOL INFO (CONT): FE3748 NC010; FE3749 NC010; FE3754 NC010;
FE3755 NC010; FE3756 NC010; FE3780 NC010; FE3781 NC010; FE3782 NC010; FE3783
NC 010; FE3794 NC010; FE3795 NC010; FE3797 NC010; FE3803 NC010; FE3807 NC010;
FE3818 NC010; FE3826 BKB160; FE3827 NC010; VLM NC010; 10 ABG NC010; 10ABGD
NC010; 10ABGF NC010; 10ANG NC010; 101 NC010; 101BG NC010; 101F NC010; 101F
NC010E; 101F NC010N; 101F NC999; 101L NC010; 101L NC010E; 103FHS NC010;
103HSL NC010; 103HSL NC010Z; 103HSL-C NC010; 122L NC010; 132F NC010; 135F
NC010; 42 NC010; 42A NC010; 4 2HSB NC010; 42HSX NC010; 45HSB NC010.
=======================================================
Regulatory Information
=======================================================
Sara Title III Information: MATERIAL NOT KNOWN TO CONTAIN TOXIC CHEMICALS UNDER
SECTION 313 OF SUPERFUND AMENDMENTS & REAUTHORIZATION ACT OF 1986 &
40 CFR PART 372. TOXICOLOGICAL INFO (CONT): 5 MG/M3, 8 HR TWA,
RESPIRABLE D UST. OTHER APPLICABLE EXPOSURE LIMITS: NYLON 66: PEL (OSHA):
NONE ESTABLISHED. TLV (ACGIH): NONE ESTABLISHED. AEL * (DUPONT): 10 MG/M3,
8HE TWA, TOTAL DUST; 5 MG/M3, 8 HR TWA, RESPIRABLE DUST. * AEL IS DUPONT'S
ACCEPTABLE EXPOSURE LIMIT. WHERE GOVERNMENTALLY IMPOSED OCCUPATIONAL EXPOSURE
LIMITS WHICH ARE LOWER THAN THE AEL ARE IN EFFECT, SUCH LIMITS SHALL TAKE
PRECEDENCE.
Federal Regulatory Information: TSCA INVENTORY STATUS: IN COMPLIANCE WITH TSCA
INVENTORY REQUIREMENTS FOR COMMERCIAL PURPOSES.
State Regulatory Information: STATE RIGHT-TO-KNOW LAWS: NO SUBSTANCES ON STATE
HAZARDOUS SUBSTANCE LIST PRESENT AT CONCENTRATION OF 1% OR MORE. FOR SPECIAL
HAZARDOUS SUBSTANCE: NONE KNOWN. SUBSTANCE ON NEW JERSEY WORKPLACE HAZARDO US
SUBSTANCE LIST PRESENT AT CONCENTRATION OF 1% OR MORE (0.1% FOR SUBSTANCES
IDENTIFIED AS CARCINOGENS, MUTAGENS OR TERATOGENS): NONE KNOWN.
=======================================================
Other Information
=======================================================
Other Information: MATERIAL IDENTIFICATION: "ZYTEL" IS A REGISTERED TRADEMARK
OF DUPONT. (SEE ECOLOGICAL INFO FOR TRADENAMES AND SYNONYMS - FP N).
RESPONSIBILITY FOR MSDS: J.P. BOLLMEIER. DUPONT ENGINEERING POLYME RS.
CHESTNUT RUN PLAZA 713. WILMINGTON, DE 19880-0713. TEL 302-999-4257.
WASTE DISPOSAL (CONT): MUST BE MADE IN ACCORDANCE WITH APPLICABLE FEDERAL,
STATE / PROVINCIAL, AND LOCAL REGULATIONS.
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: "ZYTEL" NYLON RESINS IN SYNONYM LIST OF ZYT022
Assigned IND: Y
Company: DUPONT ENGINEERING POLYMERS
Street: 1007 MARKET STREET
City: WILMINGTON DE
Zipcode: 19898
Health Emergency Phone: 1-800-441-3637
Label Required IND: Y
Date Of Label Review: 01/04/2001
Status Code: A
Origination Code: F
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: ACUTE: PROLONGED CONTACT MAY CAUSE REDNESS OF SKIN.
SIGNIFICANT SKIN PERMEATION OR SYSTEMIC TOXICITY AFTER CONTACT IS UNLIKELY.
PARTICLES OF NYLON 66 MAY CAUSE MECHANICAL IRRITATION OF EYE WITH TEARI NG,
PAIN, BLURRED VISION. CHRONIC: NO REPORTS OF HUMAN SENSITIZATION.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
MEK FREE HI-PERF THINNER 1330-20-7
111-76-2
100-41-4
108-65-6
FLOOR & PORCH ENAMEL GRAY 108-65-6
1309-37-1
13463-67-7
64742-95-6
8052-41-3
1332-58-7
1317-65-3
96-29-7
WELD-ON P-70 PRIMER FOR PVC AND CPVC PLASTIC PIPE
PSX 700 CURE, 700C00000
PROF/FLAT WALL FINISH P-B 107-21-1
25265-77-4
1317-65-3
14808-60-7
7631-86-9
13463-67-7
GLOSS ALKYD WHITE 96-29-7
64741-65-7
64742-88-7
13463-67-7
S/GL ALKYD ENAMEL DEEP BS 96-29-7
1332-58-7
64741-65-7
8052-41-3
1317-65-3
13463-67-7
MOLYSULFIDE 1317-33-5
849 8578,KODAK PROFESSIONAL EI MAGENTA (SEE SUPPL DATA)
SHIELD PRE-CLEAN 2000 68391-01-5
68956-79-6
14808-60-7
833 8758,KODAK PROFESSIONAL EI BLACK (SEE SUPPL DATA)
FASMETAL RESIN, 0136 25068-38-6
PLASTIC STEEL PUTTY (A) RESIN, 0100 25068-38-6
SILVER-COPPER-PHOSPHORUS BRAZING ALLOYS 7440-50-8
7723-14-0
7440-22-4
OUTPUT ACTIVATOR, 17100, PART OF KIT 00241 71-55-6
68411-20-1
109-87-5
67-63-0
13395-16-9
PHILLYCLAD 620 TAILSHAFT HARDENER
DIPAK E-2888A 9042-82-4
DIPAK E-2888B
3M TYPE 648 TONER, 78696986336 25767-47-9
27136-15-8
1333-86-4
8005-02-5
1317-38-0
9003-07-0
ZX1000X, LASER TYPE TONER
CONDUCTIVE GREASE AND ANTI-OXIDANT, 19-820
"ZYTEL" NYLON RESINS IN SYNONYM LIST OF ZYT022 32131-17-2
40-3905 RESIN
3694 SATIN ACRI HSE PNT - MTB 1317-65-3
13463-67-7
14807-96-6
107-21-1
29911-28-2
302 SEMIGLOSS ALKYD 8052-41-3
1317-65-3
13463-67-7
1332-58-7
64742-88-7
64742-95-6
96-29-7
302 SEMIGLOSS ALKYD 13463-67-7
96-29-7
1332-58-7
14807-96-6
8032-32-4
950 SUPER RED BARN PAINT 8052-41-3
1317-65-3
96-29-7
14807-96-6
64741-65-7
1309-37-1
4396 CLEAR STAIN BASE 8052-41-3
1317-65-3
96-29-7
64742-95-6
64741-65-7
95-63-6
7440-48-4
GARD ANTI RUST SAE 15W-40
46815 FLOOR ENAMEL GRAY 8052-41-3
1317-65-3
1332-58-7
13463-67-7
64742-95-6
7440-48-4
970 HSE AND BARN ACRY FLT RED 1317-65-3
107-21-1
25265-77-4
1309-37-1
12001-26-2
1332-09-8
2202 APT FLAT LATEX WALL PAINT 1317-65-3
107-21-1
1332-58-7
13463-67-7
1317-95-9
18416 LF GRY RUST/INH EPOXY PR 13463-67-7
14807-96-6
100-41-4
95-63-6
64742-95-6
1330-20-7
1317-95-9
7440-66-6
7440-39-3
47192 SEMIGLS ALKYD EN FED TAN 13463-67-7
64742-95-6
96-29-7
1332-58-7
8052-41-3
1317-65-3
1309-37-1
LB 1132-21
SHIPPING MATE CASE SEALING ADHESIVE
SHIPPING-MATE PALLETIZING ADHESIVE
CHRISTO-LUBE MCG III 69991-61-3
9002-84-0
SCOTCHPLY SP-381
OZZY JUICE (SW-3 TRUCK GRADE DEGREASING SOLUTION)
PUTTY HARDENER 0200; 10050, 10080, 10110, 10110G,10120 112-24-3
25154-52-3
140-31-8
68082-29-1
PUTTY HARDENER, 10130, 10260, 10610, 10620 112-24-3
25154-52-3
140-31-8
68082-29-1
PUTTY HARDENER, 10650, 11410, 11420, DE087 112-24-3
25154-52-3
140-31-8
68082-29-1
90059-5, ACIDCLEAN FR
PSX 700 BLACK RESIN, 700B90000
AERO KLEEN AVIATION SOLVENT
SAFE CARE MORE THAN GLASS (READY TO USE)
8801K22/MS35058-22
MOLSIV ADSORBENTS 13X HP 20X40 7631-86-9
1344-28-1
1313-59-3
1309-48-4
UNIVERSAL PLUS 3%/ 6% FIRE FIGHTING FOAM CONCENTRATE AR-AFFF

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net