===================== Product Identification =====================
MSDS NAME:PHOTOPOSIT THINNER TYPE P
NIIN:00N083588
MSDS Number: CGQYZ
=== Responsible Party ===
Company:SHIPLEY CO
Address:455 FOREST ST
City:MARLBOROUGH
State:MA
ZIP:01752
Country:US
Info Phone Num:508-481-7950
Emergency Phone Num:800-424-9300(CHEMTREC)
Preparer's Name:T. BLAKESLEE
CAGE:JO354
=== Contractor Identification ===
Company:SHIPLEY CO
Address:455 FOREST ST
Box:City:MARLBOROUGH
State:MA
ZIP:01752
Country:US
Phone:508-481-7950
CAGE:JO354
Company:SHIPLEY CO INC
Address:455 FOREST ST
City:MARLBOROUGE
State:MA
ZIP:01752
Country:US
Phone:508-481-7950
CAGE:0AS27
============= Composition/Information on Ingredients =============
Name:ACETIC ACID, 2-METHOXY-1-METHYLETHYL ESTER; (PROPYLENE
GLYCOL MONOMETHYL ETHER ACETATE). VP: 2.4 @ 20C.
CAS:108-65-6
RTECS #:AI8925000
Fraction by Wt: 100%
OSHA PEL:N/K
ACGIH TLV:N/K
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE EFFECTS: EYE AND SKIN CONTACT
CAN CAUSE IRRITATION, BURNING, ITCHING, REDNESS, TEARING AND
INFLAMMATION. INHALATION, INGESTION AND SKIN ABSORPTION CAN CAUSE
IRRITATION, BURNS, ITCHING, REDNESS, DIARRHEA, KIDNEY AND LIVER
DAMAGE. CHRONIC: PROLONGED, REPEATED EXPOSURE CAN CAUSE ABSORPTION
OF (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: HARMFUL AMOUNTS, CHRONIC EFFECTS
SIMILAR TO THOSE FOR INGESTION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INGEST: CONTACT MD AT ONCE. EYES: FLUSH IMMED W/PLENTY OF
WATER FOR AT LEAST 15 MINUTES. CONTACT MD AT ONCE. SKIN: FLUSH
IMMED W/PLENTY OF WATER FOR AT LEAST 15 MINUTES. REMOVE
CONTAMINATED CLOTHING. CONTACT MD. WASH CLOTHING BEFORE
REUSE.INHAL: MOVE INTO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL
RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN. CONTACT MD AT
ONCE. NOTE TO MD: (SUPDAT)
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:116F,47C
Extinguishing Media:ALCOHOL FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . USE NORMAL PROCEDURES FOR FLAMMABLE LIQUID FIRES.
CONTAINERS NEAR FIRE MAY BE COOLED W/WATER.
Unusual Fire/Explosion Hazard:PRESSURE MAY BUILD UP IN CLOSED
CONTAINERS. THIS IS ACCELERATED BY HEAT WITH POSSIBLE LIBERATION OF
COMBUSTIBLE VAPORS.
================== Accidental Release Measures ==================
Spill Release Procedures:ELIMINATE SOURCES OF IGNIT, PROVIDE ADEQ VENT
& SUITABLE PROTECTIVE CLTHG. COLLECT W/INERT ABSORBENT MATL & PLACE
IN A SUITABLE CNTNR FOR DISPOSAL. DISPOSE OF CONTAMD PROD & MATLS
USED IN CLEANING UP SPILLS & LEAKS IN MANNER APPRVD FOR THIS MATL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:WARNING! COMBUSTIBLE LIQUID. STORE IN
CLOSED ORIGINAL CONTAINER IN A COOL, DRY AREA AT 50-70F.
Other Precautions:KEEP AWAY FROM MOISTURE, OXIDANTS, METALS, HEAT AND
SOURCES OF IGNITION. AVOID STORING LONGER THAN ONE YEAR.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:THE SPECIFIC RESPIRATOR SELECTED MUST BE BASED
ON THE AIRBORNE CONCENTRATION FOUND IN THE WORKPLACE AND MUST NOT
EXCEED THE WORKING LIMITS OF THE RESPIRATOR. THE RESPIRATOR MUST BE
APPROVED BY NIOSH F OR THE SUBSTANCE OF CONCERN.
Ventilation:PROVIDE GOOD GENERAL (MECHANICAL) ROOM VENT. SPECIAL LOCAL
EXHAUST VENT IS RECOM AT POINTS WHERE VAPS CAN BE (SUPDAT)
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
SUITABLE PROTECTIVE CLOTHING TO PREVENT SKIN CONTACT.
Work Hygienic Practices:AVOID SKIN CONTACT. PRACTICE GOOD PERSONAL
HYGIENE TO PREVENT ACCIDENTAL EXPOSURE.
Supplemental Safety and Health
FIRST AID PROC: THERE IS NO SPECIFIC ANTIDOTE. TREATMENT OF
OVEREXPOSURE SHOULD BE DIRECTED AT CONTROL OF SYMPTOMS AND THE
CLINICAL CONDITION. WASTE DISP METH: THAT ANY RECOMMENDED
PROCEDURES COMPLY W /FEDERAL, STATE & LOCAL REGS FOR WASTEWATER
DISCHARGE. VENT: RELEASED INTO THE WORKPLACE AIR.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:285F,141C
Vapor Pres:SEE ING 1
Vapor Density:HVR/AIR
Spec Gravity:APPROX 1.02
Evaporation Rate & Reference:0.34 (N-BUTYL ACETATE=1)
Solubility in Water:NOT SOLUBLE
Appearance and Odor:CLEAR LIQUID WITH A SLIGHTLY SWEET ODOR.
Percent Volatiles by Volume:100 WT
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
OXIDANTS.
Stability Condition to Avoid:HEAT, SPARKS, FLAME.
Hazardous Decomposition Products:DETAILS UNKNOWN. MAY EMIT TOXIC FUMES
IF BURNED.
==================== Disposal Considerations ====================
Waste Disposal Methods:DUE TO THE NATURE OF THIS PRODUCT, DISPOSAL OF
IT, OR RESIDUES THEREFROM SHUOLD BE MADE IN COMPLIANCE W/FEDERAL,
STATE AND LOCAL ENVIRONMENTAL LAWS. CONTACT SHIPLEY TECHNICAL
REPRESENTATIVE FOR MORE I NFO. IT IS YOUR RESPONSIBILITY TO VERIFY
(SUPDAT)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|