===================== Product Identification =====================
MSDS NAME:HYDROGEN PEROXIDE 10%-35%, 2014
NIIN:00N083618
MSDS Number: CGRBF
=== Responsible Party ===
Company:VAN WATERS & ROGERS INC
Address:6100 CARILLON POINT
City:KIRKLAND
State:WA
ZIP:98033
Country:US
Info Phone Num:206-889-3400
Emergency Phone Num:800-424-9300(CHEMTREC)
CAGE:DO735
=== Contractor Identification ===
Company:VAN WATERS & ROGERS SUBSIDIARY OF UNIVAR
Address:6100 CARILLON POINT
City:KIRKLAND
State:WA
ZIP:98033
Country:US
Phone:425-889-3400
CAGE:DO735
Company:VOPAK USA INC
Address:6100 CARILLON POINT
Box:City:KIRKLAND
State:WA
ZIP:98033-7357
Country:US
Phone:425-889-3400/425-889-3617
CAGE:0STM5
============= Composition/Information on Ingredients =============
Name:HYDROGEN PEROXIDE (SARA 302)
CAS:7722-84-1
RTECS #:MX0900000
Fraction by Wt: 10-35%
OSHA PEL:1 PPM
ACGIH TLV:1 PPM; 9495
Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: 65-90%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:SUPDAT: 35%: 2-3. PH(1% SOLN): 10,20,30,35%: APPROX 5-6.
RTECS #:9999999ZZ
Name:MATLS TO AVOID: WOOD, PAPER AND OTHER COMBUSTIBLES. IRON
AND OTHER HEAVY METALS AS LISTED.
RTECS #:9999999ZZ
Name:FIRST AID: DIRECT CONT W/EYE IS SUFFICIENTLY LIKELY TO
CAUSE CORNEAL DMG, ESPECIALLY IF NOT WASHED AWAY IMMED SO (ING 6)
RTECS #:9999999ZZ
Name:ING 5: THAT CAREFUL OPHTHALMOLOGIC EVAL IS RECOM & POSS OF
LOC CORTICOSTEROID THERAPY SHOULD BE CONSIDERED. (ING 7)
RTECS #:9999999ZZ
Name:ING 6: BECAUSE OF LIKELIHOOD OF CORR EFTS ON GI TRACT AFTER
INGEST, & UNLIKELIHOOD OF SYS EFTS, ATTEMPTS AT EVAC (ING 8)
RTECS #:9999999ZZ
Name:ING 7: STOM VIA EMESIS INDUCTION/GASTRIC LAVAGE SHOULD BE
AVOIDED. THERE IS REMOTE POSS, HOWEVER, THAT A (ING 9)
RTECS #:9999999ZZ
Name:ING 8: NASOGASTRIC/OROGASTRIC TUBE MAY BE REQ FOR REDUCTION
OF SEVERE DISTENTION DUE TO GAS FORMATION.
RTECS #:9999999ZZ
Name:WASTE DISP: OF DISP MAY VARY BY LOCATION & BECAUSE
REGULATORY REQS MAY CHG, APPROP REGULATORY AGENCIES SHOULD BE(ING
11)
RTECS #:9999999ZZ
Name:ING 10: CONSIDERED PRIOR TO DISPOSAL.
RTECS #:9999999ZZ
Name:OTHER PRECS: SHOULD BE MADE ONLY OF FOLLOWING COMPAT MATLS:
GLASS, STAINLESS STEEL, ALUMINUM/PLASTIC. STOR (ING 13)
RTECS #:9999999ZZ
Name:ING 12: SHOULD CONFORM TO CNDTNS DESCRIBED IN NFPA BULLETIN
43A (CODE FOR STOR OF LIQ & SOLID OXIDIZING MATLS).(ING 14)
RTECS #:9999999ZZ
Name:ING 13: NFPA HAZ CLASS II OXIDIZER. KEEP PEOPLE AWAY. WEAR
FULL PROT CLTHG. USE WATER ONLY FOR FIRE. PROT FROM (ING 15)
RTECS #:9999999ZZ
Name:ING 14: PHYSICAL DAMAGE. DRUMS SHOULD NOT BE STACKED DURING
TRANSIT. KEEP DRUMS IN UPRIGHT POSITION.
RTECS #:9999999ZZ
Name:EYE PROTECTION: FULL LENGTH FACESHIELD .
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50 (ORAL RAT) >1193 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CORR TO EYES & GI TRACT. MAY
CAUSE IRREVERSIBLE TISS DMG TO EYES, INCL BLINDNESS. SEVERELY
IRRITATING TO NOSE, THROAT & LUNGS. CHRONIC: THERE ARE RPTS OF LIM
EVID OF CARCIN OF HYDROGEN PEROXID E TO MICE ADMIN HIGH CONCS IN
DRINKING WATER (IARC MONO 36, 1985). HOWEVER, IARC RESEARCH ON
CANCER (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS: CONCLUDED THAT HYDROGEN PEROXIDE
COULD NOT BE CLASSIFIED AS TO ITS CARCIN TO HUMANS (GRP 3 CARCIN).
ACCORDINGLY, OSHA HAZ COMMUNICATION STD (29 CFR 1910.1200) DOES NOT
REQ THAT HYDROGEN PER OXIDE BE IDENTIFIED AS A CARCIN.
Medical Cond Aggravated by Exposure:SENSITIVITIES, TERATOGENICITY,
MUTAGENICITY, SYNERGISTIC PRODS, REPRO TOX, & ANY MED CNDTNS GENLY
RECOGNIZED AS BEING AGGRAVATED BY EXPOS WERE EXAMINED & NO INFO WAS
FOUND OR IS AVAILABLE.
======================= First Aid Measures =======================
Eyes: IMMED FLUSH WITH LG AMTS OF WATER FOR AT LST 15 MINS,
LIFTING UPPER AND LOWER LIDS INTERMITTENTLY. SEE PHYS OR
OPHTHALMOLOGIST. SKIN: WASH WITH LG AMTS OF WATER. IF IRRIT
PERSISTS, OBTAIN MED AT TN. INHAL: REMOVE TO FRESH AIR. CALL A
PHYS. INGEST: DRINK PLENTY OF WATER IMMED TO DILUTE. DO NOT INDUCE
VOMIT. SEE PHYS. NOTES TO PHYS: HYDROGEN PEROXIDE AT THESE CONCS IS
A STRONG OXIDANT. (ING 5)
===================== Fire Fighting Measures =====================
Flash Point:NONCOMBUSTIBLE
Extinguishing Media:WATER, WATER FOG, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . ANY TANK OR CONTAINER SURROUNDED BY FIRE SHOULD BE
FLOODED WITH WATER FOR COOLING.
Unusual Fire/Explosion Hazard:HYDROGEN PERXIDE ITSELF IS
NONCOMBUSTIBLE. ON DECOMPOSITION, RELEASES OXYGEN WHICH MAY
INTENSIFY FIRE.
================== Accidental Release Measures ==================
Spill Release Procedures:DILUTE WITH LARGE VOLUME OF WATER AND HOLD IN
A POND OR DIKED AREA UNTIL H*2O*2 DECOMPOSES. DISPOSE OF ACCORDING
TO METHODS OUTLINED BELOW FOR WASTE DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID EXCESSIVE HEAT & CONTAM OF ANY
KIND. CONTAM MAY CAUSE DECOMP & GEN OF OXYG GAS WHICH COULD RSLT IN
HIGH PRESS & POSS CNTNR RUPTURE.
Other Precautions:PROD SHOULD NOT BE STORED IN UNVENTED CNTNR & SHOULD
BE TRANSFERRED ONLY IN PRESCRIBED MANNER. NEVER RETURN UNUSED
HYDROGEN PEROXIDE TO ORIG CNTNR. EMPTY DRUMS SHOULD BE RINSED
W/WATER BEFORE DISCARDI NG. UTENSILS USED FOR HNDLG (ING 12)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:FOR SEVERE VAPOR OR MIST (CONCENTRATION IN
EXCESS OF 10 PPM) USE NIOSH CERTIFIED SELF-CONTAINED BREATHING
APPARATUS. DO NOT USE OXIDIZABLE OXIDANTS.
Ventilation:PROVIDE GEN & LOC EXHST VENT AS NECESSARY. CONTROL MISTS IN
WORK AREA @/BELOW EXPOS GUIDELINES (TLV 1 PPM FOR 8 HRS).
Protective Gloves:LIQUID PROOF RUBBER/NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS &(ING 16)
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
SHOWER . POLYESTER/ACRYLIC FULL COVER CLTHG. RUBB/NEOPRENE
FOOTWEAR.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
PHYSICAL DATA: BP: 10%:215F,102C; 20%: 218F,103C; 30%: 223F,106C; 35%:
226F,108C. MP: 10%: 21F,-6C; 20%: 6F,-15C; 30%: -14F,-26C; 35%:
-27F,-33C. VP: 10%: 30 @30C; 20%: 28 @30C; 30%: 24 @30C; 35%: 23
@30C. SPEC GRAV(H*20=1): 10%: 1.03; 20%: 1.07; 30%: 1.11; 35%:
1.13. PH(AS IS): 10,20,30%: APPROX 2.5-3.5; (ING 3)
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:SUPDAT
Melt/Freeze Pt:M.P/F.P Text:SUPDAT
Vapor Pres:SUPDAT
Spec Gravity:SUPDAT
pH:SUPDAT
Evaporation Rate & Reference:>1 (BUTYL ACETATE=1)
Solubility in Water:100% BY WT
Appearance and Odor:CLEAR COLORLESS LIQUID. ODORLESS.
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:NO
IRON & OTHER HEAVY METALS, GALVANIZED IRON, COPPER ALLOYS, RUST, DIRT,
ORGANICS & COMBUSTS. REDUCING AGENTS, (ING 4)
Stability Condition to Avoid:EXCESSIVE HEAT, CONTAMINATION OF ANY KIND.
Hazardous Decomposition Products:OXYGEN WHICH SUPPORTS COMBUSTION.
==================== Disposal Considerations ====================
Waste Disposal Methods:ACCEPTABLE METHOD OF DISP IS TO DILUTE W/LG AMT
OF WATER & ALLOW HYDROGEN PEROXIDE TO DECOMPOSE FOLLOWED BY DISCHG
INTO SUITABLE TREATMENT SYS I/A/W ALL LOC, ST & FED LAWS, RULES,
REGS, STDS & OTHER R EQUIREMENTS. BECAUSE ACCEPTABLE METHODS(ING
10)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|