===================== Product Identification =====================
MSDS NAME:LITHIUM THIONYL CHLORIDE BATTERY
NIIN:01-406-3710
Status Code:A
MSDS Number: CJLVH
=== Responsible Party ===
Company:SAFT AMERICA INC ADVANCED BATTERY SYSTEMS DIVISION
Address:313 CRESCENT ST NE
City:VALDESE
State:NC
ZIP:28690-9643
Country:US
Info Phone Num:828-874-4111MD 410-771-3200
Emergency Phone Num:828-874-4111
Chemtrec Ind/Phone:(800)424-9300
CAGE:7X634
=== Contractor Identification ===
Company:BREN-TRONICS INC
Address:10 BRAYTON CT
Box:City:COMMACK
State:NY
ZIP:11725-3104
Country:US
Phone:631-499-5155
Contract Num:SP0430-99-M-AC23
CAGE:51828
Company:SAFT AMERICA INC ADVANCED BATTERY SYSTEMS DIVISION
Address:313 CRESCENT ST NE
Box:City:VALDESE
State:NC
ZIP:28690-9643
Country:US
Phone:828-874-4111/912-245-2806
CAGE:7X634
============= Composition/Information on Ingredients =============
Name:THIONYL CHLORIDE (SOCL2)
CAS:7719-09-7
RTECS #:XM5150000
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1 PPM
ACGIH TLV:1 PPM
ACGIH STEL:C4.9 MG/M3;C1 PPM
Name:LITHIUM (LI)
CAS:7439-93-2
RTECS #:OJ5540000
Other REC Limits:NONE RECOMMENDED
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TARGET ORGANS: EYES, SKIN, RESPIRATORY
SYSTEM (HMIS). ACUTE AND CHRONIC - IF CELL SEAL IS BROKEN, THE
SUBSTANCE AND VAPORS HAVE A CORROSIVE EFFECTS ON THE SKIN AND
MUCOUS MEMBRANES.
Explanation of Carcinogenicity:NO
Effects of Overexposure:BURNS AND IRRITATION TO RESPIRATORY SYSTEM.
Medical Cond Aggravated by Exposure:ASTHMA AND OTHER RESPIRATORY
DISEASES.
======================= First Aid Measures =======================
First Aid:IN CASE OF CONTACT WITH EYES, FLUSH IMMEDIATELY WITH WATER
FOR 15 MINUTES; WITH SKIN, WASH WITH PLENTY OF WATER AND TAKE OFF
CONTAMINATED CLOTHES; INHALATION, REMOVE FROM EXPOSURE - SEEK
MEDICAL ADVIS E.
===================== Fire Fighting Measures =====================
Extinguishing Media:USE WATER OR CO2 ON BURNING LITHIUM THIONYL
CHLORIDE CELLS OR BATTERIES. USE A CLASS D FIRE EXTINGUISHING AGENT
ONLY ON A RAW LITHIUM FIRE.
Fire Fighting Procedures:USE SELF CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:GENERATION OF CHLORINE, SULFUR DIOXIDE,
DISULFUR DICHLORIDE DURING THERMAL DECOMPOSITION.
================== Accidental Release Measures ==================
Spill Release Procedures:COVER WITH SODIUM CARBONATE OR 1:1 MIXTURE OF
SODA ASH AND SLAKED LIME. PRECIPITATE ESCAPING GASES/VAPORS BY
SPRAYING WATER. ENSURE ADEQUATE VENTILATION OR EXHAUST VENTILATION
IN THE WORKING AREA.
Neutralizing Agent:SODIUM CARBONATE
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP CONTAINER DRY AND TIGHTLY CLOSED
IN A COOL (MAX 50 DEGREE C) AND WELL VENTILATED PLACE. STORE AWAY
FROM FOOD AND DRINK. LITHIUM BATTERIES OR INDIVIDUAL CELLS SHOULD
NOT BE RECHARGED, SHORT CIRCUI TED, PUNCTURED OR MUTILATED IN ANY
WAY OR EXPOSED TO TEMPERATURE IN EXCESS OF 85C (185F).
Other Precautions:IF CONTAMINATION WITH MOISTURE OCCURS, PRODUCT WILL
RELEASE GAS CAUSING A PRESSURE BUILD-UP. TERMINALS SHOULD NOT BE
EXPOSED TO WATER, CONDUCTIVE MATERIALS OR CORROSIVE COMPOUNDS. IF
LITHIUM BATTERIES ARE EXPOSED TO A BUILDING FIRE, WITH NO EXPOSED
LITHIUM FOIL, THEY SHOULD BE COOLED WITH LARGE AMOU NT OF WATER.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:ENSURE ADEQUATE VENTILATION OR EXHAUST
VENTILATION IN THE WORKING AREA.
Ventilation:ENSURE ADEQUATE EXHAUST VENTILATION IN THE WORKING AREA.
Eye Protection:SAFETY GLASSES WITH SIDE SHIELDS.
Work Hygienic Practices:KEEP ONLY IN THE ORIGINAL CONTAINER - HANDLE
AND OPEN CONTAINER WITH CARE - ENSURE EFFECTIVE VENTILATION.
Supplemental Safety and Health
THE HCC PER TECHNICAL SUPPORT.
================== Physical/Chemical Properties ==================
HCC:V1
Melt/Freeze Pt:=190.C, 374.F
Vapor Pres:(MMHG)
Spec Gravity:(H20=1)>1
Solubility in Water:NOT SOLUBLE IN WATER
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
WATER ALKALIS.
Stability Condition to Avoid:CELLS ARE NOW REACTING PROVIDED THE CELL
SEAL REMAINS INTACT. THERMAL DECOMPOSITION BEGINS AT 140 DEGREES C.
Hazardous Decomposition Products:H, S02, SCL2, S2C/2, C/2
Conditions to Avoid Polymerization:WILL NOT OCCUR.
==================== Disposal Considerations ====================
Waste Disposal Methods:PRODUCT DECOMPOSED BY WATER MUST BE NEUTRALIZED
- MAY BE ADDED TO WASTE WATER IN SUFFICIENTLY DILUTED FORM.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.