===================== Product Identification =====================
MSDS NAME:FIRE EXTINGUISHER, CARBON DIOXIDE
NIIN:00-540-0550
Status Code:A
MSDS Number: CJVWJ
=== Responsible Party ===
Company:GENERAL FIRE EXTINGUISHER CORP
Address:1685 SHERMER RD
City:NORTHBROOK
State:IL
ZIP:60062-5315
Country:US
Info Phone Num:(708) 847-272-7500
Emergency Phone Num:INFOTRAC 1-800-535-5053
CAGE:99539
=== Contractor Identification ===
Company:GENERAL FIRE EXTINGUISHER CORP
Address:1685 SHERMER RD
Box:City:NORTHBROOK
State:IL
ZIP:60062-5315
Country:US
Phone:(708) 847-272-7500; 847-272-7500
Contract Num:SP0560-99-M-H051
CAGE:99539
============= Composition/Information on Ingredients =============
Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
= Wt:100.
OSHA PEL:9000 MG/M3;5000 PPM
ACGIH TLV:9000 MG/M3;5000 PPM
ACGIH STEL:54000 MG/M3
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CONTACT WITH LIQUID MAY CAUSE
FROSTBITE USE OF EXTINGUISHER IN CLOSED AREA MAY CAUSE DANGEROUS
CONCENTRATION OF CARBON DIXOIDE.
Explanation of Carcinogenicity:NOT LISTED.
Effects of Overexposure:CONCENTRATIONS BETWEEN 5 AND 10 PERCENT MAY
CAUSE SHORTNESS OF BREATH AND HEADACHE, OVER 10 PERCENT MAY CAUSE
UNCONSCIOUSNESS.
Medical Cond Aggravated by Exposure:QUANTITY IN FIRE EXTINGUISHER
UNLIKELY TO HAVE ANY EFFECT.
======================= First Aid Measures =======================
First Aid:REMOVE PERSON TO FRESH AIR AND VENTILATE CLOSED AREA.
================== Accidental Release Measures ==================
Spill Release Procedures:IF RELEASED CARBON DIOXIDE WILL RAPIDLY
DIFFUSE INTO ATMOSPHERE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:PROTECT FIRE EXTINGUISHER FROM
PHYSICAL DAMAGE. DO NOT EXPOSE TO TEMPERATURE ABOVE 130F.
Other Precautions:DO NOT DIRECT DISCHARGE STREAM FROM FIRE EXTINGUISHER
AT OTHER PERSONS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NOT NEEDED.
Ventilation:LOCAL: USE IN CLOSED AREA AFTER FIRE IS EXTINGUISHED.
MECHANICAL(GENERAL):USE IN CLOSED AREA AFTER FIRE IS EXTINGUISHED.
Protective Gloves:NOT NEEDED
Eye Protection:NOT NEEDED
Other Protective Equipment:NOT NEEDED.
Work Hygienic Practices:AVOID CONTACT WITH CONTENTS OF FIRE
EXTINGUISHER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================== Physical/Chemical Properties ==================
HCC:G3
Boiling Pt:=-78.5C, -109.3F
Melt/Freeze Pt:=-78.5C, -109.3F
M.P/F.P Text:SUBLIMES
Vapor Pres:850 PSI@70F
Vapor Density:1.53(AIR=1
Solubility in Water:SLIGHT
Appearance and Odor:COLORLESS, ODORLESS GAS
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:NONE.
=================== Toxicological Information ===================
Toxicological Information:NONE SPECIFIED BY MANUFACTURER.
===================== Ecological Information =====================
Ecological:NONE SPECIFIED BY MANUFACTURER.
==================== Disposal Considerations ====================
Waste Disposal Methods:NONE SPECIFIED BY MANUFACTURER.
=================== MSDS Transport Information ===================
Transport Information:FIRE EXTINGUISHER, CARBON DIOXIDE
===================== Regulatory Information =====================
SARA Title III Information:NONE SPECIFIED BY MANUFACTURER.
Federal Regulatory Information:NONE SPECIFIED BY MANUFACTURER.
State Regulatory Information:NONE SPECIFIED BY MANUFACTURER.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD ***