===================== Product Identification =====================
MSDS NAME:STRATA BLUE, 15045
NIIN:00-988-1458
MSDS Number: BGBYQ
=== Responsible Party ===
Company:ILLINOIS BRONZE POWDER & PAINT CO
Emergency Phone Num:312-438-8201
CAGE:91794
=== Contractor Identification ===
Company:ILLINOIS BRONZE PAINT COMPANY
Address:300 EAST MAIN STREET
City:LAKE ZURICH
State:IL
ZIP:60047-2580
Country:US
Phone:800-228-5635
CAGE:91794
============= Composition/Information on Ingredients =============
Name:NO INGREDIENT FOR THIS FORMULATION_INGREDIENT
===================== Hazards Identification =====================
Effects of Overexposure:EYE/THROAT/SKIN/LUNG IRRIT
======================= First Aid Measures =======================
First Aid:WASH SKIN THOROUGHLY, FLUSH EYES W/WATER, REMOVE TO FRESH
AIR. REMOVE CONTAM CLOTHING, GIVE ARTIF RESP IF NEEDED, CALL MD.
===================== Fire Fighting Measures =====================
Flash Point:-40 F -40 C
Lower Limits:1.3
Extinguishing Media:FOAM, DRY CHEM, CARBON DIOXIDE
Unusual Fire/Explosion Hazard:AVOID FIRE, HEAT, SPRAKS, IGNITION
SOURCES, STG IN DIRECT SUNLIGHT
================== Accidental Release Measures ==================
Spill Release Procedures:VENT AREA MECH, KEEP FROM FLAME, FIRE SPRAKS,
IGNITION SOURCES. DO NOT BREATHE VAPORS. CLEAN UP W/ABSORBENT MATL.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP CNTNRS CLOSED, UPRIGHT, AWAY FROM
FIRE, FLAME, SPARKS, IGNITION SOURCES, DIRECT SUNLIGHT.
Other Precautions:DO NOT PUNCTURE OR INCINERATE CANS
============= Exposure Controls/Personal Protection =============
Ventilation:LOCAL EXHST
Supplemental Safety and Health
AEROSOL, NFPA CLASS 1A FLAMMABLE LIQ
================== Physical/Chemical Properties ==================
HCC:V3
Boiling Pt:B.P. Text:42F, 5.6C
Appearance and Odor:AEROSOL
Percent Volatiles by Volume:73.0
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:PHOSGENE, CO2, HYDROGEN CHLORIDE
==================== Disposal Considerations ====================
Waste Disposal Methods:DO NOT INCINERATE CLOSED CNTNRS
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.