===================== Product Identification =====================
MSDS NAME:CONDUCTIVE EPOXY P/N 72-00008
NIIN:00-764-7475
Kit Part:Y
MSDS Number: BHFSH
=== Responsible Party ===
Company:TECHNICAL WIRE PRODUCTS, INC.
Address:129 DERMODY STREET
City:CRANFORD
State:NJ
ZIP:07016
Country:US
Info Phone Num:201-272-5500
Emergency Phone Num:201-272-5500
CAGE:53217
=== Contractor Identification ===
Company:TECHNICAL WIRE PRODUCTS INC DBA TECKNIT INC
Address:320 N NOPAL ST
City:SANTA BARBARA
State:CA
ZIP:93103-3225
Country:US
CAGE:53217
Company:TECHNICAL WIRE PRODUCTS INC, DBA. TECKNIT
Address:129 DERMODY ST
Box:City:CRANFORD
State:NJ
ZIP:07016
Country:US
Phone:908-272-5500
CAGE:07700
============= Composition/Information on Ingredients =============
Name:SILVER PLATED GLASS SPHERES
CAS:7440-22-4
Fraction by Wt: 76%
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Name:CIBA GEIGY ARALDITE 6010
CAS:25068-38-6
Fraction by Wt: 21%
===================== Hazards Identification =====================
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:YES
Health Hazards Acute and Chronic:OVEREXPOSURE MAY CAUSE HEADACHE,
NAUSEA, DIZZINESS, MODERATE IRRITATION TO SKIN AND EYES.
Explanation of Carcinogenicity:N-BUTYLGLYCIDYLETHER (BGE) (2426-08-6)
TWA = 25 PPM
Effects of Overexposure:HEADACHE, NAUSEA, DIZZINESS, MODERATE
IRRITATION TO SKIN AND EYES.
Medical Cond Aggravated by Exposure:SENSITIVE EYES AND SKIN
======================= First Aid Measures =======================
First Aid:EYE: FLUSH WITH WATER FOR 15 MIN.
SKIN: WASH WITH SOAP AND WATER AND APPLY SKIN
CREAM. INHAL: REMOVE TO FRESH AIR,
RESTORE BREA THING IF REQUIRED.INGST: DO NOT INDUCE VOMITING, CALL
PHYSICIAN
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:370F/187.78C
Lower Limits:NE
Upper Limits:NE
Extinguishing Media:FOAM, DRY CHEMICAL, CO2, WATER SPRAY OR FOG
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:NONE
================== Accidental Release Measures ==================
Spill Release Procedures:SCRAPE UP THE MATERIAL AND PLACE IN A
CONTAINER FOR RECOVERY OR SOLID WASTE DISPOSAL.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP CONTAINERS CLOSED AND STORE AT
ROOM TEMPERA- TURE.
Other Precautions:NONE
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE
Ventilation:LOCAL EXHAUST NEEDED; MECHANICAL RECOMMENDED
Protective Gloves:NORMALLY NOT NEEDED
Eye Protection:RECOMMENDED
Other Protective Equipment:NORMALLY NOT NEEDED
Work Hygienic Practices:AVOID PROLONGED OR REPEATED CONTACT WITH SKIN
Supplemental Safety and Health
NK
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:<160C
Melt/Freeze Pt:M.P/F.P Text:NA
Vapor Pres:NE
Vapor Density:< AIR
Spec Gravity:2.30
Evaporation Rate & Reference:< 1
Solubility in Water:NEGLIGIBLE
Appearance and Odor:SILVER COLORED PASTE WITH AN AMINE ODOR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
BEFORE CURING PART I PLUS PART II AVOID ORGANIC SOLVENT AND WATER
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:NONE EXCEPT CO FROM INCOMPLETE
COMBUSTION
Conditions to Avoid Polymerization:EXCESSIVE HEAT
==================== Disposal Considerations ====================
Waste Disposal Methods:LANDFILL OR INCINERATION IN ACCORDANCE WITH
LOCAL,STATE, AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|