===================== Product Identification =====================
MSDS NAME:MANGANESE DIOXIDE
NIIN:00N011557
MSDS Number: BHZFK
=== Responsible Party ===
Company:SERVICE CHEMICAL,INCORPORATED
Address:2651 PENN AVENUE
City:HATFIELD
State:PA
ZIP:19440
Country:US
Info Phone Num:215-362-0411
Emergency Phone Num:215-362-0411;800-424-9300 CHEMTREC
CAGE:1V225
=== Contractor Identification ===
Company:SERVICE CHEMICAL INC
Address:2651 PENN AVENUE
Box:City:HATFIELD
State:PA
ZIP:19440
Country:US
Phone:215-362-0411
CAGE:1V225
============= Composition/Information on Ingredients =============
Name:MANGANESE DIOXIDE (MNO*2).OSHA PEL FOR MN CMPDS;1 MG(MN)/M3
FOR FUME.ACGIH TLV FOR MN CMPDS & DUST;1 MG(MN)/M3 FOR FUME.
CAS:1313-13-9
RTECS #:OP0350000
Fraction by Wt: 82.0%
Other REC Limits:N/K
OSHA PEL:5 MG(MN)/M3 C
ACGIH TLV:5 MG(MN)/M3
Name:IRON.OSHA PEL FOR OXIDE DUST & FUME TOTAL PARTICULATE.ACGIH
TLV FOR OXIDE FUME.
CAS:7439-89-6
RTECS #:NO4565500
Fraction by Wt: 2.5%
Other REC Limits:N/K
OSHA PEL:10 MG/M3 FUME
ACGIH TLV:5 MG/M3 FUME
===================== Hazards Identification =====================
LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EXCESS & PROLONGED INHAL (GENERALLY
OVER 2 YEARS) CAN CAUSE DAMAGE TO CENTRAL NERVOUS SYSTEM.PATHOLOGY
RESEMBLES PARKINSON'S DISEASE.WORKERS ROUTINELY EXPOSED TO HIGH
CONC OF MANGANESE DUST SHOW UNUSU ALLY HIGH INCIDENCE OF RESP
DISEASE.SIGNS OF PNEUMOCONIOSIS PRESENT ONLY AFTER 6-10 YEARS EXPOS
TO IRON DUST/FUMES.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES/SKIN/INGEST:N/K .INHAL:EXCESS FUME INH CAN
PRODUCE METAL FUME FEVER (CHILLS,FEVER FEW HRS AFTER
EXPOS).EXCESS/PRLNG INH:CNS DMG (RESEMBLES PARKINSON'S).ROUTINE
EXPOS TO HIGH CONC OF MN :HIGH INCIDENCE OF RESP DISEASE.POSS
PNEUMOCONIOSIS AFTER 6-10 YEARS EXPOS TO IRON DUST/FUME (NO
DISABILITY INDICATED).
Medical Cond Aggravated by Exposure:N/K
======================= First Aid Measures =======================
Eyes:FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES,OCCASIONALLY LIFTING UPPER & LOWER EYELIDS.SKIN:WASH WITH
SOAP & WATER.INGEST:IF VICTIM IS CONSCIOUS GIVE WATER & INDUCE
VOMITING.DO NOT MAKE AN UNCONSCIOUS PERSON VOMIT.INHALATION:REMOVE
TO FRESH AIR.RINSE MOUTH & NASAL PASSAGES WITH WATER.SEEK MEDICAL
ATTENTION.
===================== Fire Fighting Measures =====================
Extinguishing Media:THIS PRODUCT DOES NOT PRESENT A FIRE
HAZARD.HOWEVER,IF A FIRE SHOULD RESULT,SMOTHER WITH DRY
CHEMICAL,SALT OR SAND.
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:MANGANESE OXIDE IS A MODERATE DISASTER
HAZARD.IT SHOULD BE KEPT AWAY FROM HEAT & FLAMMABLE MATERIALS.
================== Accidental Release Measures ==================
Spill Release Procedures:CLEAN UP USING METHODS WHICH AVOID DUST
GENERATION AND THE USE OF WATER,SUCH AS VACUUM.IF AIRBORNE DUST IS
GENERATED DURING THE CLEANUP,USE AN APPROPRIATE NIOSH APPROVED
RESPIRATOR.
Neutralizing Agent:N/K
====================== Handling and Storage ======================
Handling and Storage Precautions:MANGANESE OXIDE IS A MODERATE DISASTER
HAZARD.IT SHOULD BE KEPT AWAY FROM HEAT AND FLAMMABLE MATERIALS.
Other Precautions:N/K
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL AND GENERAL VENTILATION NECESSARY TO KEEP AIR
CONCENTRATION BELOW TLV .
Protective Gloves:N/K
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WEAR FULL CLOTHING FOR PROLONGED OR REPEATED
CONTACT.
Work Hygienic Practices:N/K
Supplemental Safety and Health
ROUTES OF ENTRY:EYE (MFR).
================== Physical/Chemical Properties ==================
Melt/Freeze Pt:M.P/F.P Text:N/K
Decomp Temp:Decomp Text:N/K
Solubility in Water:INSOLUBLE
Appearance and Odor:BLACK POWDER,NO ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ALUMINUM,RUBIDIUM ACETYLIDE,HYDROGEN SULFIDE,HYDROGEN PEROXIDE,SODIUM
PEROXIDE AND CLF*3.
Stability Condition to Avoid:AVOID HEAT
Hazardous Decomposition Products:N/K
Conditions to Avoid Polymerization:WILL NOT OCCUR.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE AND LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.