A/D COLORCOAT 庐
required between application of the final coat of A/D
Selection & Specification Data
FIREFILM餂欼II and application of A/D COLORCOAT餂?.
A/D COLORCOAT餂? is a single
Generic Type
Precautions
component, low VOC siliconized alkyd
coating. It is the required topcoat for Contents are combustible. Use only with adequate
FIREFILM餂欼II
A/D intumescent ventilation. To avoid overexposure, open windows and
fireproofing. doors or use other means to ensure fresh air entry during
application and drying. If you experience eye watering,
A/D COLORCOAT餂? offers minimal dirt
headaches or dizziness, increase fresh air or wear
collection and excellent color and gloss
respiratory protection (NIOSH/MSHA TC23C or
retention. It is available in many colors
equivalent) or leave the area. Avoid contact with eyes and
in gloss finish.
skin. Wash hands after using. Keep container closed when
not in use. Do not transfer contents to other containers for
Typical of white alkyd coatings, some
Limitations
storage.
yellowing of white and light color A/D
COLORCOAT餂? may occur in the field.
SEE MATERIAL SAFETY DATA SHEET.
Where white color retention is
important, contact your Carboline
Application Conditions
representative for recommendations.
A/D FIREFILM餂欼II must be dry before application of
Physical Data (Typical Values) topcoat - Shore 鈥淒鈥? hardness should be a minimum of 70,
measured at 70掳F (21掳C) and a minimum of 24 hours is
required between application of the final coat of A/D
VOC 2.5 Ib/gal (300 g/litre)
FIREFILM餂欼II and application of A/D COLORCOAT餂?.
Weight / Gallon 10.7Ib/gal
Do not apply A/D COLORCOAT铮? until it has been
determined that the required dry film thickness of A/D
Solids by Volume 63% 卤 2% (value for pure white)
FIREFILM铮↖II has been provided!
Apply A/D COLORCOAT铮? to a minimum dry film thickness
Solids by Weight 70% 卤 2% (value for pure white)
of 2 to 3 mils. Air, surface and material temperatures
Theoretical should be within the range of 40掳 - 120掳F (5掳 - 49掳C) and
1010 ft2/gal (24.8 m2/litre) @ 1 mil wet
Coverage at least 5掳F (3掳C) above dew point.
252 ft2/gal (6.2 m2/litre) @ 4 mils wet,
Recommended
Application Equipment
Coverage 2 mils dry (min.)
Max. Thickness Listed below are general equipment guidelines for the
2-3mils dry
Per Coat application of this product. Job site conditions may require
modifications to these guidelines to achieve the desired
Recoat Time 24 hrs @ 75掳F (24掳C), 50% R.H.
results.
Finish Gloss
The following spray equipment has
Spray
Packaging 1 and 5 gallon (U.S.) containers
been found suitable and is available
Application
1 gal. - 13 Ib (6 kg) from manufacturers such as Binks,
(General)
Shipping Weight
5 gal. - 64 Ib (29 kg) DeVilbiss and Graco.
Test reports and additional data available upon written request.
Pressure pot equipped with dual
Conventional
Surface Preparation regulators, 3/8" I.D. minimum material
Spray
hose, .052" I.D. fluid tip and
Apply, measure and record dry film thickness of A/D
appropriate air cap.
FIREFILM餂欼II according to 鈥淎/D FIREFILM餂欼II Application
Guide鈥?. Be sure specified dry film thickness has been
achieved before topcoating A/D FIREFILM餂欼II with A/D
COLORCOAT餂?.
A/D FIREFILM餂欼II must be dry before application of
topcoat - Shore 鈥淒鈥? hardness should be a minimum of 70,
measured at 70掳F (21掳C) and a minimum of 24 hours is
April 2006
To the best of our knowledge the technical data contained herein is true and accurate on the date of publication and is subject to change without prior notice. User must contact Carboline Company to verify correctness before
specifying or ordering. No guarantee of accuracy is given or implied. We guarantee our products to conform to Carboline quality control. We assume no responsibility for coverage, performance or injuries resulting from
use. Liability, if any, is limited to replacement of products. NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE BY CARBOLINE, EXPRESS OR IMPLIED, STATUTORY, BY OPERATION OF
LAW, OR OTHERWISE, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Carboline餂? and Nullifire餂? are registered trademarks of Carboline Company.
A/D COLORCOAT庐
Application Equipment continued鈥?
Pump Ratio: 30:1 (min.)*
Airless Spray
GPM Output: 3.0 (min.)
Material Hose: 3/8" I.D. (min.)
Tip Size: .013-.015"
Output PSI: 2500
Filter Size: 100 mesh
*Teflon packings are recommended
and available from the pump
manufacturer.
Avoid excessive re-brushing or
Brush & Roller
re-rolling.
(General)
Use a natural bristle brush.
Brush
Use a short-nap synthetic roller cover
Roller
with phenolic core.
Cleanup & Safety
Read and follow all caution statements
Safety
on this product data sheet and on the
MSDS for this product. Employ normal
workmanlike safety precautions. Use
adequate ventilation and wear gloves
or use protective cream on face and
hands if hypersensitive. Keep
container closed when not in use.
This product contains flammable
Caution
solvents. Keep away from sparks and
open flames. In confined areas,
workmen must wear appropriate
respiratory protection. All electrical
equipment and installations should be
made and grounded in accordance
with the National Electric Code. In
areas where explosion hazards exist,
workmen should be required to use
non-ferrous tools and wear conductive
and non-sparking shoes.
April 2006
To the best of our knowledge the technical data contained herein is true and accurate on the date of publication and is subject to change without prior notice. User must contact Carboline Company to
verify correctness before specifying or ordering. No guarantee of accuracy is given or implied. We guarantee our products to conform to Carboline quality control. We assume no responsibility for
coverage, performance or injuries resulting from use. Liability, if any, is limited to replacement of products. NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE BY CARBOLINE,
EXPRESS OR IMPLIED, STATUTORY, BY OPERATION OF LAW, OR OTHERWISE, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Carboline餂? and Nullifire餂? are
registered trademarks of Carboline Company.
|