Material Safety Data Sheet U.S. DEPARTMENT OF LABOR
May be used to comply with Occupational Safety and Health
OSHA鈥橲 Hazard Communication Standard (Non-Mandatory Form)
29 CFR 2910.1200. Standard must be Form Approved
consulted for specific requirements. OMB No. 1218-0072
Identity (As Used on Label and List) #202 Note: Blank spaces are not permitted. If any item is not applicable, or
Big D Fire D One-Shot no information is available, the space must be marked to indicate that.
Section I
Big D Industries, Inc. (800) 535-5053 (800) 654-4752
Manufacturer鈥檚 Name Emergency Telephone Number
(800) 654-4752
Telephone Number for Information
Address (number, Street, City, State, and ZIP Code)
5620 S. W. 29th Street (73179) (405) 682-2541
P. O. Box 82219 06-01-2002
Date Prepared
Oklahoma City, OK 73148 Signature of Preparer (optional)
Section II - HMIS Rating
2 4 0
Health Flammability Reactivity
Section III - Hazardous Ingredients/Identity Information
Hazardous Components (Specific Chemical Identity: Common Name(s)) OSHA PEL ACGIH TLV Other Limits
%(optional)
Rcmnd.
Iso Propanol CAS #67-63-0 400 ppm 400 ppm -
Amyl Acetate CAS #628-63-7 100 ppm 100 ppm -
Ethyl Acetate CAS #141-78-6 400 ppm 400 ppm
Hydrocarbon Propellant - Propane CAS #74-98-6 1000 ppm 1000 ppm
Isobutane CAS #75-28-5 800 ppm 800 ppm
Section IV - Physical/Chemical Characteristics
1650F Conc. 0.80
Boiling Point Specific Gravity (H2O = 1)
-43 propellant
700F 50 PSIG N/A
Vapor Pressure (mm Hg.) Melting Point
>1 <1
Vapor Density (AIR = 1) Evaporation Rate
Slight
Solubility in Water:
Produces fine mist with pleasant fragrance. Liquid is transparent.
Appearance and Odor:
Section V - Fire and Explosion Hazard Data
-500F propellant
Flash Point (Method Used) Flammable Limits N/A LEL UEL
1.8% 16.7
Carbon dioxide, dry foam, water spray
Extinguishing Media
Self contained air supply suggested.
Special Fire Fighting Procedures
Keep containers cool (below 1300F) to avoid bursting.
Unusual Fire and Explosion Hazards
N/A - Not Applicable N/D - Not Determined Page 1 N/E - Not
#202
Section VI - Reactivity Data
None
Conditions to Avoid:
Stability Unstable
X
Stable
Avoid contact with strong oxidizing agents such as nitric acid.
Incompatibility (Materials to Avoid):
None
Hazardous Decomposition or Byproducts:
Hazardous May Occur Conditions to Avoid: None
Polymerization
Will Not Occur X
Section VII - Health Hazard Data
Route(s) of Entry: Inhalation? Yes Skin? Yes Ingestion? Yes
Health Hazards (Acute and Chronic):
Acute - Propellant is an asphyxiant and may exhibit properties at high concentrate. Chronic - Unconsciousness
Carcinogenicity: NTP? No IARC Monographs? No OSHA Regulated? No
Skin - possible frostbite burn. Eyes - burning sensation. Inhalation - Headache, nausea, disorientation.
Signs and Symptoms of Exposure:
Medical Conditions
Emphysema
Generally Aggravated by Exposure:
Emergency and First Aid Procedures: Eye contact: flush with large amounts of water. May cause corneal damage on prolonged contact. Seek medical
attn.
Ingestion: Do not give anything by mouth to an unconscious person. Seek Medical attn. Inhalation: remove person to fresh air . Administer
artificial respiration if not breathing. Seek medical attn.
Section VIII - Precautions for Safe Handling and Use
Steps to be Taken in Case Material is Released or Spilled:
If container is ruptured and begins to leak, place in a well ventilated area and eliminate all ignition sources.
Waste Disposal Method: do not discard empty container in incinerator or fire. Dispose of in accordance with Local, State, and Federal regulations.
0
Precautions to be Taken in Handling and Storing: Store in cool area away from heat or open flame. Do not store above 130 F as containers may burst
releasing the highly flammable propellant. 鈥淪tore as Level Aerosol (NFPA 30B)
Other precautions: In case of rupture, ventilate to prevent concentrations from reaching flammable levels. Note: any copies or redistribution of this
M.S.D. Sheet must not be modified in any way.
Section IX - Control Measures
Self contained breathing apparatus.
Respiratory Protection (Specify Type):
Local Exhaust:: Doors & windows open N/A
Special
Ventilation
N/A
Other
Mechanical (General) Fan
Protective Gloves: Rubber or plastic for prolonged contact Eye Protection: Safety goggles for splash protection
Eye wash/shower facility nearby
Other Protective Clothing or Equipment:
Good housekeeping practices. Avoid skin/eye contact.
Work/Hygienic Practices:
N.A. = Not Applicable N.D. - Not Determined Page 2 N/E - Not Established OSHA 174, Sept. 1985