HILL MANUFACTURING INC -- 812B CPC (CIRCULATING PARTS CLNR)
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BSVTZ
MSDS NAME: 812B CPC (CIRCULATING PARTS CLNR)
Responsible Party
Name: HILL MANUFACTURING CO INC
Address: 1500 JONESBORO ROAD
City: ATLANTA GA 30315
Info Phone: 404-522-8364;404-588-4400
Emergency Phone Number: 404-522-8364;404-588-4400
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: HILL MANUFACTURING CO INC
Address: 1500 JONESBORO DR
City: ATLANTA GA 30315
Phone: 404-522-8364
=======================================================
Ingredients
=======================================================
Name: PETROLEUM HYDROCARBON FRACTIONS
ACGIH TLV: 500 PPM (MFR)
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: NO
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: EXCESSIVE INHALATION MAY CAUSE HEADACHE, DIZZINESS OR
NAUSEA.
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: EYE: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. SKIN: WASH WITH MILD
SOAP AND APPLY MILD SKIN CREAM. INHAL: GET OUT TO FRESH AIR, CALL PHYSICIAN,
USE ARTIFICIAL RESPIRATION IF NECESSARY. INGEST: CALL M D IMMED (FP N).
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: FLUSH WITH WATER INTO RETAINING AREA OR CONTAINER.
AVOID EXPOSURE TO HEAT, SPARKS AND OPEN FLAME.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE UNDER SAFE CONDITIONS IN OCCURANCE WITH LOCAL,
STATE AND FEDERAL REGULATIONS-INCINERATE UNDER SAFE CONDITIONS.
Handling And Storage Precautions: KEEP AWAY FROM HEAT, SPARKS AND OPEN FLAME.
AVOID PROLONGED CONTACT W/SKIN. ADEQUATE VENTILATION IS REQUIRED.
Other Precautions: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Text: 105F,41C
Extinguishing Media: WATER SPRAY, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: NONE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN (FP N).
Ventilation: LOCAL EXHAUST: YES.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APRV CHEM WORK GOGG (FP N).
Other Protective Equipment: EYE BATH AND SAFETY SHOWER MEETING ANSI DESIGN
CRITERIA.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Physical/Chemical Properties
=======================================================
HCC: F4
B.P. Text: 350F,177C
Vapor Pres: 5.4PSIA
Vapor Density: 3.3
Spec Gravity: 0.83(H2O=1)
Appearance and Odor: BLUE LIQUID, WITH MILD PETROLEUM ODOR
Percent Volatiles by Volume: 98
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: AVOID STRONG OXIDIZERS.
Hazardous Decomposition Products: THERMAL DECOMPOSITION MAY YIELD CARBON
MONOXIDE.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: 812B CPC (CIRCULATING PARTS CLNR)
Company: HILL MANUFACTURING CO INC
Street: 1500 JONESBORO DR
City: ATLANTA GA
Zipcode: 30315
Health Emergency Phone: 404-522-8364;404-588-4400
Label Required IND: Y
Date Of Label Review: 05/03/1993
Status Code: C
Label Date: 05/03/1993
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: None
Fire Hazard: Moderate
Reactivity Hazard: None
Hazard And Precautions: KEEP AWAY FROM HEAT, SPARKS AND OPEN FLAME. ACUTE:
EXCESSIVE INHALATION MAY CAUSE HEADACHE, DIZZINESS OR NAUSEA. CHRONIC: NONE
LISTED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.
*** END OF RECORD *** |
|
|