===================== Product Identification =====================
MSDS NAME:PR-1539-U CAMBER GRADE, PART A
NIIN:00N066983
Kit Part:Y
MSDS Number: CBFFN
=== Responsible Party ===
Company:PRODUCTS RESEARCH & CHEMICAL CORP
Address:5430 SAN FERNANDO RD
Box:1800
City:GLENDALE
State:CA
ZIP:91203
Country:US
Info Phone Num:818-240-2060
Emergency Phone Num:800-228-5635;800-424-9300(CHEMTREC)
Preparer's Name:C.J.K.
CAGE:DO563
=== Contractor Identification ===
Company:PRC-DESOTO INTERNATIONAL, INC. A PPG INDUSTRIES COMPANY
Address:5430 SAN FERNANDO RD
Box:1800
City:GLENDALE
State:CA
ZIP:91209
Country:US
Phone:818-240-2060
CAGE:83574
Company:PRODUCTS RESEARCH & CHEMICAL
Address:NOW DBA COURTAULDS AEROSPACE
Box:1800
City:GLENDALE
State:CA
ZIP:91209
Phone:818-240-2060
CAGE:DO563
============= Composition/Information on Ingredients =============
Name:ACETIC ACID, 2-METHOXY-1-METHYLETHYL ESTER; (PROPYLENE
GLYCOL MONOMETHYL ETHER ACETATE) (PM ACETATE). VAP DENS: (ING 2)
CAS:108-65-6
RTECS #:AI8925000
Fraction by Wt: 5%
OSHA PEL:N/K
ACGIH TLV:100 PPM (MFR)
Name:ING 1: 4.6. EVAP RATE:0.4. LEL:1.5%. UEL:7%.
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:DIETHYLTOLUENE DIAMINE; (DETDA)
CAS:68479-98-1
Fraction by Wt: 15%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:TEXANOL BENZYL PHTHALATE; (PHTHALATE ESTER)
CAS:16883-83-3
Fraction by Wt: 20%
OSHA PEL:5 MG/M3 (MFR)
ACGIH TLV:5 MG/M3 (MFR)
Name:CALCIUM CARBONATE
CAS:1317-65-3
RTECS #:EV9580000
Fraction by Wt: 20%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST
Name:BURNT UMBER PIGMENT; (METAL OXIDE SILICATE)
CAS:12713-03-0
OSHA PEL:N/K
ACGIH TLV:N/K
Name:SILICA GEL; (SILICA)
CAS:112945-52-5
RTECS #:VV7310000
OSHA PEL:6 MG/M3
ACGIH TLV:10 MG/M3
Name:AMMONIUM POLYPHOSPHATE
CAS:68333-79-9
OSHA PEL:N/K
ACGIH TLV:N/K
Name:SULFURIC ACID, CALCIUM SALT; (CALCIUM SULFATE)
CAS:7778-18-9
RTECS #:WS6920000
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYES:SEV IRRIT, MAY CAUSE
BURNING, TEARING, REDDENING, POSS TRANSIENT CORNEAL INJURY.
SKIN:EXPECTED TO BE TOX BY DERMAL ABSORPTION, IN RARE INSTANCES,
SENSIT HAS BEEN REPORTED TO OCCUR IN HUMANS . INHAL:MAY CAUSE DIZZ,
DROW & FATG. DUE TO LOW VOLATILITY AT ROOM TEMP OF DETDA, INHAL IS
NOT EXPECTED(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:RTE OF EXPOS. HOWEVER, HEATED/SPRAYED
MATL MAY GIVE OFF SIGNIFICANT AMTS OF VAP. INGEST:EXPECTED TO BE
TOX. CHRONIC:TWO-YR FEEDING STUDY IN RATS SHOWED DETDA CAUSED EFTS
IN PANCREAS, LIVER, T HYROID & EYES, INCR IN NUMBER OF TUMORSIN
LIVER & THYROID OF MALE RATS WAS FOUND.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
Eyes:BEGIN IMMED IRRIGATION W/COOL WATER FOR AT LST 15 MINS,
CONSULT MD. SKIN:IMMED FLUSH W/PLENTY OF WATER FOR AT LST 15 MINS
WHILE REMOVING CONTAM CLTHG & SHOES, WASH CLTHG BEFORE USE. IF
SYMPS ARE PRESENT CONSULT MD. INHAL:REMOVE TO FRESH AIR. IF SYMPS
ARE PRESENT CONSULT MD. INGEST:INDUCE VOMIT, GIVE 2 GLASSES OF
WATER TO DILUTE EFT. NEVER GIVE ANYTHING BY MOUTH TO UNCON PERS.
GET MED ATTN.
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:184F,84C
Lower Limits:SEE ING 1
Upper Limits:SEE ING 1
Extinguishing Media:CO*2, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . USE WATER TO COOL HEAT EXPOSED CONTAINERS.
Unusual Fire/Explosion Hazard:HIGH TEMPERATURES MAY CAUSE PRESSURE
BUILD-UP IN CLOSED CONTAINERS.
================== Accidental Release Measures ==================
Spill Release Procedures:WEAR NIOSH/MSHA APPROVED AIR-SUPPLIED
RESPIRATOR FOR MAJOR UNVENTILATED SPILL. COVER W/ABSORBANT. SCOOP
INTO CONTAINERS. CLEAN-UP RESIDUE W/1,1,1-TRICHLOROTHANE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID INGESTION.
Other Precautions:CALCIUM CARBONATE IS LISTED AS REQD BY 29 CFR
1910:1200 BECAUSE IT APPEARS ON AIRBORNE CONTAMS LIST. HOWEVER, IN
THIS PROD IT IS IN FULLY ENCAPSULATED FORM & THEREFORE IS NOT HAZ
TO USERS UNDER NORMAL CIRCUMSTANCES. IF CURED PROD IS(SUPDAT)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WHEN APPLYING IN CONFINED AREAS, OR IN OTHER
CIRCUMSTANCES LIKELY TO PRODUCE AIRBORNE LEVELS OF SOLVENT OR
ISOCYANATE IN EXCESS OF PEL, USE A NIOSH/MSHA APPROVED AIR-SUPPLIED
RESPIRATOR.
Ventilation:GENERAL VENTILATION TO MAINTAIN VAPORS BELOW PEL.
Protective Gloves:SOLVENT RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING & BEFORE SMOKING
OR EATING.
Supplemental Safety and Health
OTHER PREC:SANDED OR GROUNDED SO AS TO RELEASE RESPIRABLE PARTICLES,
SUITABLE NIOSH/MSHA APPROVED RESPIRATORY PROTECTION SHOULD BE USED.
EYE PROT:& FULL LENGTH FACESHIELD .
================== Physical/Chemical Properties ==================
Vapor Density:SEE ING 1
Spec Gravity:1.54
Evaporation Rate & Reference:SEE INGREDIENT 1.
Solubility in Water:SLIGHT
Appearance and Odor:BROWN PASTE.
Percent Volatiles by Volume:11
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OXIDES OF CARBON & NITROGEN.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . NOT A HAZARDOUS WASTE ACCORDING TO EPA REGULATIONS.
CONSULT STATE REGULATIONS PRIOR TO DISPOSAL OF SPILLAGE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|