Search   
MSDS  
:
 OCTREO SCAN
CAS  
:
 138661-02-6
87-89-8
6132-04-3
490-79-9
5949-29-1
50800-85-6
7647-01-0
7705-08-0
7732-18-5
NAME  
:
 lyophilized reagent; (pentetreotide)
inositol
sodium citrate; (trisodium citrate dihydrate)
gentistic acid
citric acid monohydrated; (citric acid monohydrate)
indium salt; (indium chloride in-111)
hydrochloric acid (sara 302/313) (cercla)
ferric chloride (cercla)
water
lyophilized material (consisting of ings 1 - 5)
indium chloride in-111 sterile solution-0.2m (consisting of
=====================  Product Identification  =====================

MSDS NAME:OCTREO SCAN
NIIN:00N066947
MSDS Number: CBFBZ
=== Responsible Party ===
Company:MALLINCKRODT MEDICAL INC
Address:2703 WAGNER PLACE
City:MARYLAND HEIGHTS
State:MO
ZIP:63043
Country:US
Info Phone Num:314-770-7800
Emergency Phone Num:800-424-9300(CHEMTREC)
CAGE:FO650
=== Contractor Identification ===
Company:MALLINCKRODT DIAGNOSTICS
Address:2703 WAGNER PLACE
Box:City:MARYLAND HEIGHTS
State:MO
ZIP:63043-3421
Country:US
Phone:314-344-3800
CAGE:2A916
Company:MALLINCKRODT MEDICAL INC
Address:2703 WAGNER PLACE
City:MARYLAND HEIGHTS
State:MO
ZIP:63043-3421
Country:US
Phone:314-770-7800/314-895-2000
CAGE:FO650

=============  Composition/Information on Ingredients  =============

Name:LYOPHILIZED REAGENT; (PENTETREOTIDE)
CAS:138661-02-6
Fraction by Wt: 0.06%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Name:INOSITOL
CAS:87-89-8
Fraction by Wt: 62.46%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Name:SODIUM CITRATE; (TRISODIUM CITRATE DIHYDRATE)
CAS:6132-04-3
Fraction by Wt: 22.49%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Name:GENTISTIC ACID
CAS:490-79-9
RTECS #:LY3850000
Fraction by Wt: 12.49%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Name:CITRIC ACID MONOHYDRATED; (CITRIC ACID MONOHYDRATE)
CAS:5949-29-1
RTECS #:GE7810000
Fraction by Wt: 2.5%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Name:INDIUM SALT; (INDIUM CHLORIDE IN-111)
CAS:50800-85-6
Fraction by Wt: <1%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Name:HYDROCHLORIC ACID  (SARA 302/313) (CERCLA)
CAS:7647-01-0
RTECS #:MW4025000
Fraction by Wt: <1%
OSHA PEL:5 PPM, C
ACGIH TLV:5 PPM, C
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Name:FERRIC CHLORIDE (CERCLA)
CAS:7705-08-0
RTECS #:LJ9100000
Fraction by Wt: <1%
OSHA PEL:1 MG/M3 (FE)
ACGIH TLV:1 MG/M3 (FE)
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: >99%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Name:LYOPHILIZED MATERIAL (CONSISTING OF INGS 1 - 5)
OSHA PEL:N/K 
ACGIH TLV:N/K 

Name:INDIUM CHLORIDE IN-111 STERILE SOLUTION-0.2M (CONSISTING OF
    INGS 6 - 9)
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO	Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:HAZ INGS FOUND IN PROD ARE SKIN
    & EYE IRRITS, BUT DUE TO FORM OF MATL (LYOPHILIZED PELLET) NO
    ADVERSE HLTH EFTS ARE EXPECTED TO OCCUR FROM EXPOS. FOLLOWING INFO
    APPLIES TO RADIOACTIVE INDIUM (IN -111) IN KIT: INHAL:INDIUM
    CHLORIDE DOES NOT EASILY BECOME AIRBORNE. NOT EXPECTED TO BE HLTH
    HAZ VIA (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:INHAL. INGEST:MAY CAUSE ASYMPTOMATIC
    PHYSIOLOGICAL UPTAKE BY SPECIFIC TARGET ORGANS/TISSUES. SKIN
    CONT:NOT EXPECTED TO PRDCE ANY ACUTE ADVERSE HLTH EFTS. EYE CONT:NO
    ADVERSE EFT EXPECTED, BUT  MAY CAUSE MECH IRRIT. CHRONIC:HLTH RISKS
    ASSOC W/CHRONIC RADIA EXPOS (CANCER, LEUKEMIA, GENETIC &
    TERATOGENIC EFTS) ARE BELIEVED TO INVOLVE LEVELS OF RADIA EXPOS
    WHICH ARE MUCH HIGHER THAN THOSE PERM ITTED OCCUPATIONALLY. THIS
    PROD CONTAINS SUBSTANCE KNOWN TO STATE OF CALIFORNIA TO CAUSE
    CANCER.
Medical Cond Aggravated by Exposure:NO INFORMATION FOUND.

=======================  First Aid Measures  =======================

First Aid:MIN FIRST AID IS EXPECTED TO BE REQD AS RSLT OF EXPOS TO
    LYOPHILIZED MATL. SKIN:WASH EXPOS SKIN W/SOAP & WATER. SEEK MED
    ATTN IF IRRIT DEVELOPS. EYES:WASH EXPOS EYES THORO W/RUNNING WATER
    FOR AT LST 1 5 MINS. SEEK MED ATTN IF IRRIT DEVELOPS. FOLLOWING
    INFO APPLIES TO RADIOACTIVE INDIUM (IN-111):INHAL/INGEST:NOTIFY
    RADIA SFTY PERS IMMED. AMT OF MATL INHALED/INGESTED SHOULD BE
    ASSESSED & DOCUMENTED.  SKIN:WASH AFFECTED AREA THORO W/SOAP &
    WATER UNTIL NO MORE RADIOACTIVITY CAN BE REMOVED. ALWAYS BLOT DRY.
    DO NOT ABRADE SKIN. NOTIFY RADIA SFTY PERS. EYES:WASH W/WATER FOR
    AT LST 15 MINS/UNTIL NO MORE  RADIOACTIVITY CAN BE REMOVED. (SUP
    DAT)

=====================  Fire Fighting Measures  =====================

Extinguishing Media:USE ANY MEANS SUITABLE FOR EXTINGUISHING
    SURROUNDING FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT A FLAMMABLE MATERIAL. NOT CONSIDERED
    TO BE A FIRE OR EXPLOSION HAZARD.

==================  Accidental Release Measures  ==================

Spill Release Procedures:IF PROD IS RECEIVED IN LEAKING CNDTN/ANY
    LOSS/RELS OF RADIOACTIVE CONTENTS OCCURS, NOTIFY YOUR RADIA SFTY
    DEPT & MFR AT (314)770-7800. ALL CLEANUP OPERATIONS SHOULD BE
    PERFORMED TO STD OPERATING PROCS  (SOP'S) ESTABLISHED FOR YOUR
    FACILITY & BY NRC/OTHER APPLIC LOC, STATE/FED REGS. RQ:IN-111=100
    CI; HYDROGEN CHLORIDE(ACID)=5000 LBS; FERRIC CHLORIDE=1000 LBS.
    RELS TO AIR, LAND/WATER OF (SUP DAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DRUG SHOULD BE STORED AT 2C-8C BOTH
    PRIOR TO & FOLLOWING RECONSTITUTION W/INDIUM CHLORIDE IN-111 &
    DISCARDED AFTER 6 HRS FROM TIME OF PREPARATION.
Other Precautions:PROT FROM LIGHT. AFTER RECONSTITUTION, HNDLG TIME
    SHOULD BE KEPT TO MIN & APPROP SHIELDING SHOULD BE USED. STOR &
    DISP OF PROD SHOULD BE CONTROLLED IN MANNER THAT IS IN COMPLIANCE
    W/APPROP REGS OF GOV T AGENCY AUTH TO LICENSE USE OF THIS
    RADIONUCLIDE. NO SMOKING, EATING/DRINKING SHOULD BE ALLOWED IN  ANY
    AREA(OTHER INFO)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
    EXPOSURE OF CONCERN . NOT EXPECTED TO REQUIRED PERSONAL RESPIRATOR
    USAGE.
Ventilation:PROPERLY SEALED CONTAINERS ARE NOT EXPECTED TO REQUIRE ANY
    SPECIAL VENTILATION.
Protective Gloves:DISPOSABLE PLASTIC, LATEX/RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA . LABCOAT. HNDLG DEVICES SUCH AS SYRINGE
    SHIELDS & TONGS SHOULD BE USED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
APPEAR/ODOR:VIAL (INDIUM 111). FIRST AID PROC: NOTIFY RADIATION SAFETY
    PERSONNEL. SPILL PROC: THESE HAZ SUBSTANCES WHICH EXCEED RQ MUST BE
    REPORTED TO THE NATIONAL RESPONSE CENTER AT 800-424-8802.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Solubility in Water:SOMEWHAT SOLUBLE
Appearance and Odor:LYOPHILIZED WHITE PELLT IN 10 ML VIAL. CLEAR,
    COLORLESS LIQ IN 10 ML (SUP DAT)

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS & REDUCING AGENTS.
Stability Condition to Avoid:PROTECT FROM LIGHT.
Hazardous Decomposition Products:WHEN HEATED TO DECOMP, LYOPHILIZED
    MATL MAY EMIT CARBON DIOXIDE & CARBON MONOXIDE; SOLN MAY EMIT
    RADIOACTIVE FUMES CNTNG IN-111.

====================  Disposal Considerations  ====================

Waste Disposal Methods:PROD RECONSTITUTED W/INDIUM CHLORIDE IN-111 IS
    RADIOACTIVE WASTE UNTIL ACTIVITY HAS DECAYED TO NONDECTABLE LEVELS.
    RADIOACTIVE WASTE MUST BE HNDLD I/A/W PROCS ESTABLISHED BY YOUR
    RADIA SFTY OFFICER, N RC & OTHER APPLIC REGS. IF MED WASTE IS
    INVOLVED, SUCH AS BLOOD, BLOOD PRODS/SHARPS, WASTE MUST BE H NDLD
    AS BIOHAZARD & DISPOSED OF (OTHER INFO)

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
OCTREO SCAN 138661-02-6
87-89-8
6132-04-3
490-79-9
5949-29-1
50800-85-6
7647-01-0
7705-08-0
7732-18-5
TRA-DUCT 2905 HARDENER 90-72-2
26950-63-0
112-24-3
107-15-3
POLYDIMETHYLSILOXANE, RTV6428A 71-43-2
108-88-3
68083-19-2
14808-60-7
SILICONE COMPOUND, RTV6428B 68083-19-2
68037-59-2
14808-60-7
DEOX 2200 7697-37-2
DEOX 2200 ADDITIVE 7722-84-1
GAGEKOTE 5 PROTECTIVE COATING PART A 90-72-2
GAGEKOTE 5 PROTECTIVE COATING PART B 25068-38-6
97-99-4
CATALYST FOR GLOSS FINISHES MIL-C-22750D, PT-426-I 78-93-3
68410-23-1
107-98-2
71-36-3
AMICON T661A 1344-28-1
2426-08-6
AMICON T661B
FOIL-FAST EPOXY INJECTION GEL COMPONENT A - (SUPDAT) 1317-65-3
25068-38-6
14807-96-6
1314-13-2
ELASTIC CEMENT COMPONENT A 101-68-8
68515-48-0
ELASTIC CEMENT COMPONENT B 9003-11-6
68515-48-0
110-63-4
34094, GREEN 383, MARINE CORP C.A.R.C. SUPDAT) 872-50-4
1308-38-9
68187-49-5
14464-46-1
14808-60-7
SIKAGARD 62-PART A (ALL COLORS), 601 68477-31-6
25085-99-8
E 2113-A, 3020570 25085-99-8
13463-67-7
1317-65-3
112945-52-5
56-81-5
E 2113-B, 3020560 68410-23-1
117-81-7
1317-65-3
112945-52-5
56-81-5
PDL 2601-10, B COMPONENT 107-13-1
WR-LPU PAINT BASE CLEAR 872-50-4
121-44-8
112-15-2
WR-LPU CROSSLINKER 57116-45-7
112-15-2
PR-1539-U CAMBER GRADE, PART A 108-65-6
68479-98-1
16883-83-3
1317-65-3
12713-03-0
112945-52-5
68333-79-9
7778-18-9
PR-1539-U CAMBER GRADE, PART B 66101-60-8
5124-30-1
108-65-6
1163-19-5
1309-64-4
7440-38-2
68920-70-7
21645-51-2
PR-1539-U CAMBER GRADE, PART C 9016-87-9
101-68-8
PRO-LINE PL-15 CHROMIUM GREEN OXIDE, 790-330 111-46-6
1308-38-9
PRO-LINE PL-14 BULLETIN RED, 790-320 111-46-6
9016-45-9
ALL-TINT PL-3 RAW UMBER, 790-222 111-46-6
1333-86-4
AGERITE GELTROL, P00607 64771-72-8
71-43-2
108-95-2
WATER STRIPPABLE COATING 690, 191C587 112-34-5
263 700 DURAPRIME WHITE 1188, 263 700 13701-59-2
25265-77-4
107-21-1
A-9080, RR-5 HOT EF 647-41-6
67-63-0
68476-86-8
SUPEROL GLYCERINE USP, KOSHER SUPEROL GLYCERINE USP 56-81-5
FRAZEE 67-64-1
64742-89-8
64742-96-4
141-78-6
64-17-5
763-69-9
108-83-8
110-19-0
67-63-0
78-93-3
1330-20-7
WHITE, INT PVA WALL SEALER, WHITELINE 009 107-21-1
64742-88-7
14808-60-7
95-63-6
50-00-0
INDOPOL L-10 9003-29-6
CUTTING FLUID AEROSOL, 91016 9038-95-3
115-10-6
102-71-6
71-43-2
140-88-5
108-88-3
7732-18-5
BUTACENE 800 RESIN, S01116 128-37-0
PREP PAK NEUTRALIZER/CONDITIONER, 320260 497-19-8
77-92-9
EXPO TOWELETTES WHITEBOARD CLEANER 7732-18-5
67-63-0
111-76-2
SERCON R-12 30 CYL EA UN1028 75-71-8
HEAT TRANSFER 570 64742-54-7
HEAD CLEANING SOLUTION 67-63-0
151 COOLING SYSTEM QUICK FLUSH 67-63-0
61-78-1
7320-34-5
100% NEATSFOOT OIL 8002-64-0
AIM AFG565 CLEAR THIN SPREAD ADHESIVE 8032-32-4
67-56-1
COPY MODULE FOR FP-820 (BLACK), FQ-U160 25153-46-2
1317-61-9
FOG JUICE 112-27-6
METAL MOVER 71-55-6
A110 64-17-5
A115 BROAD SPECTRUM MICROBICIDE FOR (SUPDAT) 142-59-6
96-45-7
107-15-3
124-40-3

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net